• Title/Summary/Keyword: Compression position

Search Result 240, Processing Time 0.027 seconds

Pelvic Compression Belt Convergence Impact on the Thickness of Multifidus and Erector Spinae Muscles (골반압박벨트가 뭇갈래근과 척추세움근의 근두께에 융합적으로 미치는 영향)

  • Baek, In-Cheol;Shim, Jae-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.5
    • /
    • pp.51-57
    • /
    • 2016
  • The purpose of this study was to determine the effectiveness of the pelvic compression belt on the thickness of the erector spinae and multifidus during hip extension on quadruped position. Thirty male university students volunteered to participate in this study. The pelvic compression belt was positioned below the anterior superior iliac spines with the stabilizing pressure using elastic compression bands. Subjects were instructed to perform hip extension in quadruped position with and without applying the pelvic compression belt. The thickness of the erector spinae and multifidus was measured ultrasound during prone position, quadruped position without applying pelvic compression belt and quadruped position applying pelvic compression belt. Data were analyzed using repeated ANOVA. Muscle thickness of multifidus was significantly higher applying the pelvic compression belt than without applying the pelvic compression belt (p<.05). Muscle thickness of elector spinae was significantly higher applying the pelvic compression belt than without applying the pelvic compression belt (p<.05). Therefore, the research can contribute to the prescription and application of quadruped position exercises in clinical practices.

Comparison of Qualities of Chest Compression according to Changes of Position in Cardiopulmonary Resuscitation Performance (심폐소생술 시행 위치변화에 따른 흉부압박의 질 비교)

  • Kwon, Hay-Rran;Park, Dae-Sung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • Purpose : This study is equivalence experiment performed to test practice effects between experimental group from both left and right direction of mannequin and control group having practice from only right direction in cardiopulmonary resuscitation education. Methods : Subject of the research were total 71 elementary and middle school teachers in J province who had not experience to have cardiopulmonary resuscitation. They were divided into experimental group of 35 participants who practiced cardiopulmonary resuscitation from both right and left direction of mannequin on Dec. 27, 2009 and control group of 36 participants who performed cardiopulmonary resuscitation from only right direction of mannequin on Dec. 28, 2009. Collected data were analyzed by SPSS/PC+(version 14.0). Results : 1. There was no statistically significant difference by sex among general characteristics of the subjects. 2. According to the quality of chest compression performed from the right direction of mannequin, experimental group showed better results in proper depth (time), insufficient depth (time), too lowered compression position (time) and inexact position (time) than control group(p<.05). In the quality of chest compression from the left side of mannequin, experimental group performed better results in proper depth (time), insufficient depth (time), inexact compression position (time) and mean chest compression depth(mm) than control group(p<.05) and also in more left-centered compression position (time) than control group(p<.001). 3. The quality of chest compression by experimental group, the right side of mannequin was superior in proper depth (time) to the left side of mannequin (p<.001) and showed better results in insufficient depth (time) and chest compression/recoil rate (p<.05). According to the quality of chest compression by control group, the right side of mannequin showed superior results in proper depth (time), insufficient depth (time), too left-centered compression position (time) and mean chest compression depth (mm) (p<.05) to the left side of mannequin. Conclusion : The group having practice from both right and left sides of mannequin was superior in the quality of chest compression to the group having practice from only right side of mannequin. How to practice cardiopulmonary resuscitation from both right and left sides of mannequin can be recommended and practice from left side of mannequin is also useful.

Comparing the accuracy of saddle position and traditional position in head-up cardiopulmonary resuscitation (Head-up CPR 시 처치자의 위치에 따른 심폐소생술 정확도 비교)

  • Yoon, Byoung-Gil;Park, Jung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.2
    • /
    • pp.99-107
    • /
    • 2019
  • Purpose: This study aimed to identify the position for the most accurate head-up cardiopulmonary resuscitation (CPR) by comparing saddle position CPR (SPCPR) and traditional CPR (TCPR). Methods: Sixty certified persons who completed a basic life support provider course between May 1 and June 21, 2019 were enrolled in the study. The participants were asked to perform 2 minutes of CPR, and the depth of chest compression, rate, position, full release, and hands off time were assessed. Accuracy was evaluated based on data collected from a smart phone application connected to the manikin via bluetooth and analyzed using frequency, percentage, t-test, analysis of variance and ${\chi}^2$. Results: The accuracy of chest compression was statistically significantly higher for SPCPR, 63.03%[${\pm}8.75$] for SPCPR and 55.50%[${\pm}10.17$] for TCPR [t=3.074, p=.003]. The depth of chest compression was statistically significantly greater for SPCPR, 4.51cm[${\pm}0.45$] for SPCPR and 4.16cm[${\pm}0.61$] for TCPR [t=2.503, p=.015]. The rate of chest compression was statistically significantly higher for TCPR, 105/min[${\pm}10.79$] for SPCPR and 111/min[${\pm}11.57$] for TCPR [t=-2.008, p=.049]. Accuracy of position of chest compression was statistically significantly higher for SPCPR, 96.10%[${\pm}13.73$] for SPCPR and 79.93%[${\pm}30.34$] for TCPR [t=2.659, p=.011]. Accuracy of full release was higher with SPCPR, with 86.30%[${\pm}30.53$] for SPCPR and 71.10%[${\pm}36.05$] for TCPR, but the difference was not statistically significant [t=1.762, p=.083]. Conclusion: Saddle position CPR was found to be more accurate than TCPR in the performance of manual head-up CPR.

Effect of an Application of Pelvic Compression Belt on the Strength of Hip Flexor in Healthy Young Adult (골반벨트 적용이 건강 성인의 고관절 굴곡근 근력에 미치는 영향)

  • Yoon, Dong-Joon;Kim, Suhn-Yeop;Lee, Eun-Hee;Kim, Se-Lim;Oh, Duck-Won
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.4
    • /
    • pp.35-42
    • /
    • 2008
  • Background : To assess the effect of a pelvic compression belt on the strength of hip flexor in healthy young individuals. Study design: Pre- and post-treatment measurement design on one factor was used. Methods : 30 healthy volunteers (male: 15, female: 15) participated in this study. Dynamometer was used to measure the strength of hip flexor, and measurements were performed before and after the application of the pelvic compression belt at neutral position of hip joint and at 30 cm raised position from floor with straight leg in supine. Results : After the application of the pelvic compression belt, the strengths of hip flexor measured at both positions were significantly increased when compared with before the application (p<.05). However, at neutral position of hip joint and at 30cm raised position from floor, there were significantly different in the changing patterns in the strengths of hip flexor between men and women (p>.05). Conclusion : The findings suggest that the pelvic compression belt is helpful in strengthening hip muscles. With easy application, it is sufficiently feasible for clinical use.

  • PDF

The Impact on the accuracy of the basic CPR according to position and foot-board height of the basic CPR provider (심폐소생술 제공자의 발판 높이와 자세가 기본심폐소생술의 정확도에 미치는 영향)

  • Choi, Eun-Sook;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.27-41
    • /
    • 2008
  • Purpose : The purpose of this study was to supply basic data for the impact on the accuracy of basic CPR according to position and foot-board height of basic CPR provider. Methods : Study design was within - group design. Subjects were 25 EMT-P Students in K city. Interventions was basic CPR performed on a resuscitation manikin placed on a hospital bed, kneeling on the bed adjacent to the manikin. Data was analyzed using descriptive statistics and Friedman test. Results : In case of the basic CPR performed on a resuscitation manikin placed on a hospital bed, ventilation accuracy was the highest in less than 160 cm height, foot-board height : $34.2{\pm}1.48cm$, 91.4% and in 161-165 cm height, foot-board height : $26.0{\pm}2.14cm$, 88.4% and in 171-175 cm height, foot-board height : $23.0{\pm}1.41cm$, 91.3% and in the above 176 cm, kneeling on the bed, 95%. Chest compression accuracy was the highest in less than 160 cm height, foot-board height : $30.2{\pm}1.48cm$, 95.6% and in 161-165 cm height, kneeling on the bed, 97.6% and in 171-175 cm height, kneeling on the bed, 98.5% and in the above 176 cm, kneeling on the bed, 98.7% and foot-board height : $20.5{\pm}1.91cm$, 98.7%. Chest compression error was due to too weak : 2.0-35.4 times. There were ststistically significant differences in 191-195 cm group according to chest compression mean depths($x^2=10.824$, p = .013) and chest compression error (p = .040). Conclusion : In contrast to current guidelines, the position and foot-board height of basic CPR provider are very important to the accuracy of the basic CPR. Furthermore, we recommend that a using real time audiovisual feedaback system significantly improve the quality of chest compression and ventilation during resuscitation.

  • PDF

Data compression algorithm with two-byte codeword representation (2바이트 코드워드 표현방법에 의한 자료압축 알고리듬)

  • 양영일;김도현
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.3
    • /
    • pp.23-36
    • /
    • 1997
  • In tis paper, sthe new data model for the hardware implementation of lempel-ziv compression algorithm was proposed. Traditional model generates the codeword which consists of 3 bytes, the last symbol, the position and the matched length. MSB (most significant bit) of the last symbol is the comparession flag and the remaining seven bits represent the character. We confined the value of the matched length to 128 instead of 256, which can be coded with seven bits only. In the proposed model, the codeword consists of 2 bytes, the merged symbol and the position. MSB of the merged symbol is the comression flag. The remaining seven bits represent the character or the matched length according to the value of the compression flag. The proposed model reduces the compression ratio by 5% compared with the traditional model. The proposed model can be adopted to the existing hardware architectures. The incremental factors of the compression ratio are also analyzed in this paper.

  • PDF

Effects of Bridge Exercise with Pelvic Compression Belt on Electromyographic Activities of Selected Lumbopelvic Muscles in Young Adults with Lumbar Instability

  • Cha, Hyun-Gyu;Choe, Yu-Won;Wu, Yan-Ting;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • PURPOSE: This study assessed the effect of the pelvic compression belt on the electromyographic activity of erector spinae (ES), internal oblique (IO), rectus femoris (RF), and biceps femoris (BF) after bridge exercise with pelvic belt compression in subjects with lumbar instability. METHODS: Forty subjects with lumbar instability volunteered for this study. We asked them to perform the bridge exercise while wearing a pelvic belt compression for 30 minutes five times weekly over a six week period. The pelvic compression belt was adjusted just below the anterior superior iliac spines with stabilizing pressure using elastic compression bands during bridge position. Surface electromyographic data were collected from the erector spinae (ES), internal oblique (IO), rectus femoris (RF) and biceps femoris (BF). RESULTS: After the six week intervention, the experimental group improved significantly. Muscle activation significantly decreased in the erector spinae, rectus femoris, and biceps femoris, and increased in the internal oblique muscle in bridge position while wearing a PCB (P <.01). CONCLUSION: Our findings suggest that the bridge exercise with pelvic belt compression is helpful to reduce activation in superficial muscles and lower extremity muscles such as erector spinae (ES), rectus femoris (RF), biceps femoris (BF) and increase activation in deep trunk muscle such as the internal oblique (IO).

Optimal Positioning of Heating Lines in a Compression Molding Die Using the Boundary Element Method (경계요소법을 이용한 압축성형다이 가열선의 최적위치 설계)

  • 이부윤;조종래
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1478-1485
    • /
    • 1993
  • A shape optimization problem is formulated to determine the optimal position of heating lines in a compression molding die. The objective of the problem is that the cavity surface would be maintained by a prescribed uniform temperature. A boundary integral equation for the sensitivity of the temperature in terms of hole position is derived using the method of shape design sensitivity analysis. The boundary element method is employed to analyze the temperature and sensitivity field of the die. The sensitivity calculation algorithm is incorporated in an optimization routine. To demonstrate a numerical implementation, an example problem arising in thermal design of a compression molding die is dealt with, showing that the number of heating lines chosen for the die strongly affects the ultimate uniformity of the cavity surface temperature.

The Effect of Compression Molding with Inclined Force for Fiber - Reinforced Thermoplastics (섬유강화 플라스틱 복합판의 압축성형에 있어서 경사하중의 영향 (AL망의 적층소재의 유동에 의하여))

  • 김만수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.63-67
    • /
    • 1994
  • A main property for fiber reinforced thermoplastic composite material in compression molding is the flow of fibers. This flow is so effective a long direction of acting force that this study examined for the inclined angel of 30$^{\circ}$, 45$^{\circ}$ and 6$^{\circ}$. Below the near softing temperature of plastic, the fiber has been fractured at a point so that the fiber strength is smaller then the local hydrostatic stress in the mold. It has been found that the position of fracture is changing accrding to the incling angle. In case of the above softing temperature, the larger the inclined is, the farther the flow of fiber move. Also the plastic flow has been progresed with the cicular are type.

  • PDF

A Novel Position Sensorless Speed Control Scheme for Permanent Magnet Synchronous Motor Drives

  • Won, Tae-Hyun;Lee, Man-Hyung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.125-132
    • /
    • 2002
  • PMSMS (permanent magnet synchronous motors) are widely used in industrial applications and home appliances because of their high torque to inertia ratio, superior power density, and high efficiency. For high performance control, accurate informations about the rotor position is essential. Sensorless algorithms have lately been studied extensively due to the high cost of position sensors and their low reliability in harsh environments. A novel position sensorless speed control for PMSMs uses indirect flux estimation and is presented in this paper. Rotor position and angular velocity are estimated by the proposed indirect flux estimation. Linkage flux and magnetic field flux are calculated by the voltage equations and the measured phase current without any integration. Instead of linkage flux calculation with integral operation, indirect flux and differential magnetic field are used for the estimation of rotor position. A proper rejection technique fur current noise effect in the calculation of differential linkage flux is introduced. The proposed indirect flux detecting method is free from the integral rounding error and linkage flux drift problem, because differential linkage flux can be calculated without any integral operation. Furthermore, electrical parameters of the PMSM can be measured by the proposed TCM (time compression method) for soft starting and precise estimation of rotor position. The position estimator uses accurate electrical parameters that are obtained from the proposed TCM at starting strategy. In the operating region, a proper compensation method fur temperature effect can compensate fir the estimation error from the variation of electrical parameters. The proposed novel position sensorless speed control scheme is verified by the experimental results.