• Title/Summary/Keyword: Compression measurement points

Search Result 17, Processing Time 0.031 seconds

The Comparison on the Compression Measurement Value of Medical Compression Stockings (수입 의료용 압박스타킹의 압력 측정치 비교)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

In DCT,Image Data Compression via Directional Zonal Filters (DCT 변환상에서 방향성 Zonal 필터를 이용한 화상 데이터 압축)

  • 정동범;김해수;조승환;이근영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.2
    • /
    • pp.172-179
    • /
    • 1991
  • In this paper we have proposed an efficient coding algorithm using directional filtering. First an image is transformed by using DCT which has better energy compaction and then the transformed image is divided into a low frequency component and several high frequency components. The transformed coefficients of each parts are transmitted respectively by using huffman code and these are transformed inversely at receiver. For the directional components total edge images are reconstructed at zero crossing points. We are able to reduce the amount of data by getting of complex component and making directional angles 90. As a results, this proposed method is better than that of Kunt in respect of processing time and memories. We have 38dB of image quality with objective measurement of PSNR and 0.26bpp of compression ratio which is acceptable.

  • PDF

A Comparison of Chest Compression Quality According to 2 Rescuers' Teamwork-Oriented Encouragement Method in Cardiopulmonary Resuscitation(CPR) Guidelines for 2010 (2010년 심폐소생술 가이드라인에서 2인 구조자의 팀워크 중심의 격려방법에 따른 가슴압박 질 비교)

  • Park, Sang-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5169-5178
    • /
    • 2012
  • The purpose of this study was to examine difference in quality of chest compression according to encouragement method of focusing on two rescuers' teamwork in CPR guideline for 2010. Subjects were randomly extracted the Dept. Emergency Medical Technology students who completed the curriculum of CPR. A group was divided into the group with one-time encouragement(33 people) and the group with continuous encouragement(33 people). Measurement period was progressed from April 30, 2012 to May 7. The collected data were analyzed with SPSS WIN program(version 12.0). As a result of research, the accuracy of chest compression(time, %) was higher(p<.05) in the group with one-time encouragement(118.72 times, 78.54%) than the group with continuous encouragement(95.12 times, 62.96%). As for the recognition of subjective concentration, the recognition as saying of being helpful for concentration was higher(p<.05) in the group with one-time encouragement(3.90 points) than the group with continuous encouragement(3.12 points). Even as for the recognition of subjective fatigue relief, the recognition as saying of being helpful for fatigue relief was higher(p<.05) in the group with one-time encouragement(3.96 points) than the group with continuous encouragement(3.30 points).

The Current Measurement by Electrode Distance of Organic Monolayers (유기단분자막의 전극거리에 따른 전류 측정)

  • 이경섭;전동규;오재한;강용철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.169-172
    • /
    • 1998
  • We have investigates a surface pressure, a displacement current and a charge measurement by distance of between electrode 1 and water surface of organic monolayers. And the displacement current was generated during compression of Arachidic acid mono1ayers at a air-water interface. The result from our work show that the displacement current of a Langmuir(L) film for Arachidic acid monolayers has the different maximum points according to the electrode distance. We are known that the displacement current and a charge was generated in inverse proportion to electrode distance d.

  • PDF

A Calculation of Compression Index of the South Coast Soft Clay Utilizing Field Measurement (계측자료를 활용한 남해안 연약 점성토의 압축지수 산정)

  • Lee, Changouk;Park, Choonsik;Kwon, Hyeonjin;Kim, Jonghwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.6
    • /
    • pp.23-30
    • /
    • 2015
  • This study analyzed degree of disturbance, using specimens by laboratory test with large block specimens and piston samplers collected from the Korea's two typical soft ground districts: South coast Gwangyang and Yangsan. To assess the characteristics of compression index of laboratory test incurred by disturbance, the compression index of laboratory test was compared with the back analysis compression index resulting from the analysis of the measured settlement. The analysis of specimen disturbance of the laboratory test results with the piston specimens of the two districts found that the qualities of most specimens were poor and the settlement predicted by the laboratory test compression index was underestimated. The analysis of test material taken from nearby areas proved that the disturbance degrees of large block specimens were lower than that of the piston specimens. The hyperbolic method, Hoshino method, Asaoka method, and ${\sqrt{S}}$ method, all of which are predictive methods using measured settlement, were employed to reach a conclusion that reliabilities of each predictive method except predictive material of a few points were the same. To compensate the disturbance effects on compression index of the piston specimens, we suggested a new modification formula that estimates compression index of piston specimens, using Schmertmann's corrected compression index, and back analysis compression index from the analysis of predictive settlement.

Measurement of the Displacement Currents Induced by the Monolayers on the Water surface of KUHN Type LB Apparatus (KUHN형 LB장치의 수면상에 전개된 단분자막의 변위전류 측정)

  • 박태곤;송경호;박근호;권명수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.83-86
    • /
    • 1994
  • On this paper, the structural changes of molecules on the water surface were monitored by the measuring system of displacement currents. The measuring system was constructed at home-made Kuhn type LB(Langmuir -Blodgett) deposition apparatus. Solutions of 4-octyl -4\\`- (5-car boxy$.$ -pentamethyleneoxy) azobenzene molecules (8A5H) and stearic acid(C$\_$18/) were spreaded at the air-water interface respectively, and the currents inducted by the dynamic behavior of molecules were measured when the molecules were the molecules were pressed by barrier. From C$\_$18/ mo1ecules two distinct peaks of displacement currents were obtained, which show that the orientations of mo1ecules were charged largely at these Points. The reversibility of displacement currents by compression and expansion was obtained from 8A5H molecules, which shows the compressed molecules which shows the compressed molecules have a tendency to disperse after the compression. But it was not obtained from C$\_$18/ molecules which means that this molecules disperse not easily by decreasing the pressure of the barrier.

  • PDF

The Effectiveness and Safety of Acupuncture for Recovery of Patients with Vertebral Compression Fractures: A Systematic Review and Meta-analysis (척추 압박 골절 환자의 회복에 대한 침 치료의 유효성 및 안전성 평가: 체계적 문헌 고찰과 메타분석)

  • Bae, Ji min;Lee, Myeong su;Choi, Ji won;Yang, Gi young;Kim, Kun hyung
    • Korean Journal of Acupuncture
    • /
    • v.36 no.1
    • /
    • pp.1-18
    • /
    • 2019
  • Objectives : The purpose of this study was to evaluate the effectiveness and safety of acupuncture treatment for recovery of patients with vertebral compression fracture(VCF). Methods : We searched ten English and Chinese and seven Korean database up to April 2018. Randomised controlled trials(RCTs), quasi-RCTs, non-radomised Controlled Trials(CCTs) were eligible. Quasi-RCTs and CCTs were assessed only for safety assessment. Pain and adverse events were primary outcome of this review. Quality of life, dysfunction, patient satisfaction, incidence of new vertebral compression fracture were regarded as secondary outcomes. The risk of bias was assessed by two independent authors using the Cochrane risk of bias tool. Level of evidence was tabulated using the GRADE methods. Results : Of 1656 screened, 15 RCTs, 1 quasi-RCT and 3 CCTs were included. Number of participants per study ranged from 45 to 135. Most of the studies had unclear or high risk of bias and considerable heterogeneity in terms of type of intervention, comparison and time-points for outcome measurement. Compared to usual care alone, acupuncture combined with usual care showed short-term favorable results for pain relief in patients with VCF(5 studies, n=252, MD -1.05 point on a 0 to 10 point scale, 95% CI -1.45 to -0.65, $I^2=74%$). Four studies reported mild and temporary adverse events, and no serious adverse events were reported. One study descriptively reported that acupuncture was effective for improving quality of life without providing numerical outcomes. There were no reports of patient satisfaction and incidence of new VCF. Conclusions : Level of evidence is very low for the effectiveness and safety of acupuncture for pain, harms and other clinical outcomes in patients with VCF. Included studies suffered from incomplete reporting, high or unclear risk of bias and substantial heterogeneity between studies. Future high-quality RCTs are needed to assess whether acupuncture is beneficial for recovery of patients with VCF.

A Novel Compressed Sensing Technique for Traffic Matrix Estimation of Software Defined Cloud Networks

  • Qazi, Sameer;Atif, Syed Muhammad;Kadri, Muhammad Bilal
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.10
    • /
    • pp.4678-4702
    • /
    • 2018
  • Traffic Matrix estimation has always caught attention from researchers for better network management and future planning. With the advent of high traffic loads due to Cloud Computing platforms and Software Defined Networking based tunable routing and traffic management algorithms on the Internet, it is more necessary as ever to be able to predict current and future traffic volumes on the network. For large networks such origin-destination traffic prediction problem takes the form of a large under- constrained and under-determined system of equations with a dynamic measurement matrix. Previously, the researchers had relied on the assumption that the measurement (routing) matrix is stationary due to which the schemes are not suitable for modern software defined networks. In this work, we present our Compressed Sensing with Dynamic Model Estimation (CS-DME) architecture suitable for modern software defined networks. Our main contributions are: (1) we formulate an approach in which measurement matrix in the compressed sensing scheme can be accurately and dynamically estimated through a reformulation of the problem based on traffic demands. (2) We show that the problem formulation using a dynamic measurement matrix based on instantaneous traffic demands may be used instead of a stationary binary routing matrix which is more suitable to modern Software Defined Networks that are constantly evolving in terms of routing by inspection of its Eigen Spectrum using two real world datasets. (3) We also show that linking this compressed measurement matrix dynamically with the measured parameters can lead to acceptable estimation of Origin Destination (OD) Traffic flows with marginally poor results with other state-of-art schemes relying on fixed measurement matrices. (4) Furthermore, using this compressed reformulated problem, a new strategy for selection of vantage points for most efficient traffic matrix estimation is also presented through a secondary compression technique based on subset of link measurements. Experimental evaluation of proposed technique using real world datasets Abilene and GEANT shows that the technique is practical to be used in modern software defined networks. Further, the performance of the scheme is compared with recent state of the art techniques proposed in research literature.

Modeling of the friction in the tool-workpiece system in diamond burnishing process

  • Maximov, J.T.;Anchev, A.P.;Duncheva, G.V.
    • Coupled systems mechanics
    • /
    • v.4 no.4
    • /
    • pp.279-295
    • /
    • 2015
  • The article presents a theoretical-experimental approach developed for modeling the coefficient of sliding friction in the dynamic system tool-workpiece in slide diamond burnishing of low-alloy unhardened steels. The experimental setup, implemented on conventional lathe, includes a specially designed device, with a straight cantilever beam as body. The beam is simultaneously loaded by bending (from transverse slide friction force) and compression (from longitudinal burnishing force), which is a reason for geometrical nonlinearity. A method, based on the idea of separation of the variables (time and metric) before establishing the differential equation of motion, has been applied for dynamic modeling of the beam elastic curve. Between the longitudinal (burnishing force) and transverse (slide friction force) forces exists a correlation defined by Coulomb's law of sliding friction. On this basis, an analytical relationship between the beam deflection and the sought friction coefficient has been obtained. In order to measure the deflection of the beam, strain gauges connected in a "full bridge" type of circuit are used. A flexible adhesive is selected, which provides an opportunity for dynamic measurements through the constructed measuring system. The signal is proportional to the beam deflection and is fed to the analog input of USB DAQ board, from where the signal enters in a purposely created virtual instrument which is developed by means of Labview. The basic characteristic of the virtual instrument is the ability to record and visualize in a real time the measured deflection. The signal sampling frequency is chosen in accordance with Nyquist-Shannon sampling theorem. In order to obtain a regression model of the friction coefficient with the participation of the diamond burnishing process parameters, an experimental design with 55 experimental points is synthesized. A regression analysis and analysis of variance have been carried out. The influence of the factors on the friction coefficient is established using sections of the hyper-surface of the friction coefficient model with the hyper-planes.