• 제목/요약/키워드: Compression measurement points

검색결과 17건 처리시간 0.029초

수입 의료용 압박스타킹의 압력 측정치 비교 (The Comparison on the Compression Measurement Value of Medical Compression Stockings)

  • 도월희;김남순
    • 한국의류학회지
    • /
    • 제37권8호
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측 (Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites)

  • 김학수;권동준;왕작가;구가영;김대식;이춘수;박종만
    • Composites Research
    • /
    • 제26권3호
    • /
    • pp.201-206
    • /
    • 2013
  • 전기저항 측정법을 이용하여 전도성을 띄는 소재는 손상예측이 가능하다. 본 연구에서는 차량용 소재로 이용하는 폴리프로필렌(PP)를 이용할 때 재료 내부에 발생될 손상 평가법을 고안하였다. PP 내부에 전도성을 부여하기 위해 탄소나노튜브(CNT)를 0.5 wt% 삽입하여 CNT/PP 복합재료를 제조하였다. 손상 평가를 하기 위해 시편 내부에 구리선을 삽입하여 가로와 세로, 대각선 구간을 설정하여 측정하였다. 시편의 모형은 $20^{\circ}$ 휘어진 시편을 사용하였다. 동적 압축 실험에 따른 전기저항 측정을 통해 구간별로 전기저항 변화도를 분석하였다. 동적 압축 실험에 따른 구간별 전기저항 변화도의 신호는 재료 내부에 전가된 응력을 나타내는 신호이다. 전기저항 측정 구간에서 전기저항 변화도가 높은 경우는 미세 손상이 발생되었음을 의미한다. 전기저항 측정법을 이용한 동적 압축 실험에 따른 예상 손상부위와 실제 파괴 실험을 통해 본 평가 방법을 이용하여 재료 내부 미세 손상을 예측할 수 있는 방법임을 확인하였다.

DCT 변환상에서 방향성 Zonal 필터를 이용한 화상 데이터 압축 (In DCT,Image Data Compression via Directional Zonal Filters)

  • 정동범;김해수;조승환;이근영
    • 한국통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.172-179
    • /
    • 1991
  • In this paper we have proposed an efficient coding algorithm using directional filtering. First an image is transformed by using DCT which has better energy compaction and then the transformed image is divided into a low frequency component and several high frequency components. The transformed coefficients of each parts are transmitted respectively by using huffman code and these are transformed inversely at receiver. For the directional components total edge images are reconstructed at zero crossing points. We are able to reduce the amount of data by getting of complex component and making directional angles 90. As a results, this proposed method is better than that of Kunt in respect of processing time and memories. We have 38dB of image quality with objective measurement of PSNR and 0.26bpp of compression ratio which is acceptable.

  • PDF

2010년 심폐소생술 가이드라인에서 2인 구조자의 팀워크 중심의 격려방법에 따른 가슴압박 질 비교 (A Comparison of Chest Compression Quality According to 2 Rescuers' Teamwork-Oriented Encouragement Method in Cardiopulmonary Resuscitation(CPR) Guidelines for 2010)

  • 박상섭
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5169-5178
    • /
    • 2012
  • 본 연구는 2010년 심폐소생술 가이드라인에서 2인 구조자의 팀워크 중심에서 격려방법에 따른 가슴압박 질 차이를 알아보고자 한다. 대상자는 심폐소생술 교육과정을 이수한 응급구조과 재학생을 무작위 추출하였다. 집단은 1회 격려집단(33명)과 연속적 격려집단(33명)으로 구분하였다. 측정 기간은 2012년 4월 30일부터 5월 7일까지 진행되었다. 수집된 자료는 SPSS WIN program(version 12.0)으로 분석하였다. 연구결과 가슴압박 정확도(회, %)는 1회 격려집단(118.72회, 78.54%)이 연속적 격려집단(95.12회, 62.96%) 보다 정확도 질이 높았다(p<.05), 주관적 집중력 인식은 1회 격려집단(3.90점)이 연속적 격려집단(3.12점) 보다 집중력에 도움이 된다는 인식이 높았고(p<.05), 주관적 피로도 완화 인식도 1회 격려집단(3.96점)이 연속적 격려집단(3.30)보다 피로도 완화에 도움이 된다는 인식이 높았다(p<.05).

유기단분자막의 전극거리에 따른 전류 측정 (The Current Measurement by Electrode Distance of Organic Monolayers)

  • 이경섭;전동규;오재한;강용철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1998
  • We have investigates a surface pressure, a displacement current and a charge measurement by distance of between electrode 1 and water surface of organic monolayers. And the displacement current was generated during compression of Arachidic acid mono1ayers at a air-water interface. The result from our work show that the displacement current of a Langmuir(L) film for Arachidic acid monolayers has the different maximum points according to the electrode distance. We are known that the displacement current and a charge was generated in inverse proportion to electrode distance d.

  • PDF

계측자료를 활용한 남해안 연약 점성토의 압축지수 산정 (A Calculation of Compression Index of the South Coast Soft Clay Utilizing Field Measurement)

  • 이창욱;박춘식;권현진;김종환
    • 한국지반환경공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.23-30
    • /
    • 2015
  • 본 연구는 국내의 대표적인 연약지반인 남해안 광양지역과 양산지역의 피스톤 샘플러와 대형블록시료로 수행된 실내시험 시료를 이용하여 교란도 분석을 시행하고 교란에 따른 실내시험 압축지수 특성을 평가하기 위하여 계측침하량 분석에 의한 역해석 압축지수와 비교 분석하였다. 본 연구대상지역의 피스톤 시료에 의한 실내시험 결과로 시료교란도 분석을 수행한 결과 대부분 시료가 품질이 불량한 것으로 평가되어 실내시험결과로 산정된 압축지수를 이용한 설계 예측침하량이 과소평가되었음을 알 수 있었다. 인근지역에서 수행된 시험자료에 대한 교란도 분석결과 대형블록시료가 피스톤 시료보다 교란도가 작은 것으로 분석되었다. 계측침하량을 이용한 장래침하량 예측기법인 쌍곡선법, Hoshino법, Asaoka법, ${\sqrt{S}}$법으로 예측한 결과 일부 측점의 예측자료를 제외하고는 예측기법별 신뢰도는 동일한 것으로 분석되었다. 피스톤 시료의 압축지수에 대한 교란영향을 보정하기 위하여 Schmertmann의 수정 압축지수와 계측침하량 분석에 의한 역해석 압축지수를 이용하여 피스톤 시료의 압축지수를 추정하는 새로운 보정식을 제시하였다.

KUHN형 LB장치의 수면상에 전개된 단분자막의 변위전류 측정 (Measurement of the Displacement Currents Induced by the Monolayers on the Water surface of KUHN Type LB Apparatus)

  • 박태곤;송경호;박근호;권명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.83-86
    • /
    • 1994
  • On this paper, the structural changes of molecules on the water surface were monitored by the measuring system of displacement currents. The measuring system was constructed at home-made Kuhn type LB(Langmuir -Blodgett) deposition apparatus. Solutions of 4-octyl -4\\`- (5-car boxy$.$ -pentamethyleneoxy) azobenzene molecules (8A5H) and stearic acid(C$\_$18/) were spreaded at the air-water interface respectively, and the currents inducted by the dynamic behavior of molecules were measured when the molecules were the molecules were pressed by barrier. From C$\_$18/ mo1ecules two distinct peaks of displacement currents were obtained, which show that the orientations of mo1ecules were charged largely at these Points. The reversibility of displacement currents by compression and expansion was obtained from 8A5H molecules, which shows the compressed molecules which shows the compressed molecules have a tendency to disperse after the compression. But it was not obtained from C$\_$18/ molecules which means that this molecules disperse not easily by decreasing the pressure of the barrier.

  • PDF

척추 압박 골절 환자의 회복에 대한 침 치료의 유효성 및 안전성 평가: 체계적 문헌 고찰과 메타분석 (The Effectiveness and Safety of Acupuncture for Recovery of Patients with Vertebral Compression Fractures: A Systematic Review and Meta-analysis)

  • 배지민;이명수;최지원;양기영;김건형
    • Korean Journal of Acupuncture
    • /
    • 제36권1호
    • /
    • pp.1-18
    • /
    • 2019
  • Objectives : The purpose of this study was to evaluate the effectiveness and safety of acupuncture treatment for recovery of patients with vertebral compression fracture(VCF). Methods : We searched ten English and Chinese and seven Korean database up to April 2018. Randomised controlled trials(RCTs), quasi-RCTs, non-radomised Controlled Trials(CCTs) were eligible. Quasi-RCTs and CCTs were assessed only for safety assessment. Pain and adverse events were primary outcome of this review. Quality of life, dysfunction, patient satisfaction, incidence of new vertebral compression fracture were regarded as secondary outcomes. The risk of bias was assessed by two independent authors using the Cochrane risk of bias tool. Level of evidence was tabulated using the GRADE methods. Results : Of 1656 screened, 15 RCTs, 1 quasi-RCT and 3 CCTs were included. Number of participants per study ranged from 45 to 135. Most of the studies had unclear or high risk of bias and considerable heterogeneity in terms of type of intervention, comparison and time-points for outcome measurement. Compared to usual care alone, acupuncture combined with usual care showed short-term favorable results for pain relief in patients with VCF(5 studies, n=252, MD -1.05 point on a 0 to 10 point scale, 95% CI -1.45 to -0.65, $I^2=74%$). Four studies reported mild and temporary adverse events, and no serious adverse events were reported. One study descriptively reported that acupuncture was effective for improving quality of life without providing numerical outcomes. There were no reports of patient satisfaction and incidence of new VCF. Conclusions : Level of evidence is very low for the effectiveness and safety of acupuncture for pain, harms and other clinical outcomes in patients with VCF. Included studies suffered from incomplete reporting, high or unclear risk of bias and substantial heterogeneity between studies. Future high-quality RCTs are needed to assess whether acupuncture is beneficial for recovery of patients with VCF.

A Novel Compressed Sensing Technique for Traffic Matrix Estimation of Software Defined Cloud Networks

  • Qazi, Sameer;Atif, Syed Muhammad;Kadri, Muhammad Bilal
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권10호
    • /
    • pp.4678-4702
    • /
    • 2018
  • Traffic Matrix estimation has always caught attention from researchers for better network management and future planning. With the advent of high traffic loads due to Cloud Computing platforms and Software Defined Networking based tunable routing and traffic management algorithms on the Internet, it is more necessary as ever to be able to predict current and future traffic volumes on the network. For large networks such origin-destination traffic prediction problem takes the form of a large under- constrained and under-determined system of equations with a dynamic measurement matrix. Previously, the researchers had relied on the assumption that the measurement (routing) matrix is stationary due to which the schemes are not suitable for modern software defined networks. In this work, we present our Compressed Sensing with Dynamic Model Estimation (CS-DME) architecture suitable for modern software defined networks. Our main contributions are: (1) we formulate an approach in which measurement matrix in the compressed sensing scheme can be accurately and dynamically estimated through a reformulation of the problem based on traffic demands. (2) We show that the problem formulation using a dynamic measurement matrix based on instantaneous traffic demands may be used instead of a stationary binary routing matrix which is more suitable to modern Software Defined Networks that are constantly evolving in terms of routing by inspection of its Eigen Spectrum using two real world datasets. (3) We also show that linking this compressed measurement matrix dynamically with the measured parameters can lead to acceptable estimation of Origin Destination (OD) Traffic flows with marginally poor results with other state-of-art schemes relying on fixed measurement matrices. (4) Furthermore, using this compressed reformulated problem, a new strategy for selection of vantage points for most efficient traffic matrix estimation is also presented through a secondary compression technique based on subset of link measurements. Experimental evaluation of proposed technique using real world datasets Abilene and GEANT shows that the technique is practical to be used in modern software defined networks. Further, the performance of the scheme is compared with recent state of the art techniques proposed in research literature.

Modeling of the friction in the tool-workpiece system in diamond burnishing process

  • Maximov, J.T.;Anchev, A.P.;Duncheva, G.V.
    • Coupled systems mechanics
    • /
    • 제4권4호
    • /
    • pp.279-295
    • /
    • 2015
  • The article presents a theoretical-experimental approach developed for modeling the coefficient of sliding friction in the dynamic system tool-workpiece in slide diamond burnishing of low-alloy unhardened steels. The experimental setup, implemented on conventional lathe, includes a specially designed device, with a straight cantilever beam as body. The beam is simultaneously loaded by bending (from transverse slide friction force) and compression (from longitudinal burnishing force), which is a reason for geometrical nonlinearity. A method, based on the idea of separation of the variables (time and metric) before establishing the differential equation of motion, has been applied for dynamic modeling of the beam elastic curve. Between the longitudinal (burnishing force) and transverse (slide friction force) forces exists a correlation defined by Coulomb's law of sliding friction. On this basis, an analytical relationship between the beam deflection and the sought friction coefficient has been obtained. In order to measure the deflection of the beam, strain gauges connected in a "full bridge" type of circuit are used. A flexible adhesive is selected, which provides an opportunity for dynamic measurements through the constructed measuring system. The signal is proportional to the beam deflection and is fed to the analog input of USB DAQ board, from where the signal enters in a purposely created virtual instrument which is developed by means of Labview. The basic characteristic of the virtual instrument is the ability to record and visualize in a real time the measured deflection. The signal sampling frequency is chosen in accordance with Nyquist-Shannon sampling theorem. In order to obtain a regression model of the friction coefficient with the participation of the diamond burnishing process parameters, an experimental design with 55 experimental points is synthesized. A regression analysis and analysis of variance have been carried out. The influence of the factors on the friction coefficient is established using sections of the hyper-surface of the friction coefficient model with the hyper-planes.