• Title/Summary/Keyword: Compression absorption

Search Result 205, Processing Time 0.027 seconds

Numerical Simulation of a Two-Stage Hybrid Heat Pump (2단 압축 하이브리드 히트펌프의 특성 시뮬레이션)

  • Jeong, Si-Young;Yun, Han-Gu;Park, Ki-Woong;Park, Seong-Ryong;Kim, Min-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • Hybrid heat pumps, which combine the vapor compression and absorption heat pump cycle, can efficiently produce hot water of $80^{\circ}-90^{\circ}C$ from the low temperature of ${\sim}50^{\circ}C$. In this study, the performance of a two-stage hybrid heat pump (HHP) was compared with a single-stage hybrid heat pump using EES (Engineering Equation Solver). For the same operating conditions, the two-stage HHP showed a slightly higher COP (Coefficient Of Performance) and more stable operating conditions than the single-stage HHP. Moreover, the maximum working fluid temperature of the two-stage HHP was found to be lower than that of the single-stage HHP by about 40 K, which makes the working conditions of the lubricating oil safer. The COPs of both systems decreased with increasing UA-values. However, the heat output of the HHP was increased at the same time.

Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading

  • Mohammadi, Masoud;Kafi, Mohammad A.;Kheyroddin, Ali;Ronagh, Hamid R.
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.163-177
    • /
    • 2020
  • Concentrically Braced Frames (CBFs) are commonly used in the construction of steel structures because of their ease of implementation, rigidity, low lateral displacement, and cost-effectiveness. However, the principal disadvantage of this kind of braced frame is the inability to provide deformation capacity (ductility) and buckling of bracing elements before yielding. This paper aims to present a novel Composite Buckling Restrained Fuse (CBRF) to be utilized as a bracing segment in concentrically braced frames that allows higher ductility and removes premature buckling. The proposed CBRF with relatively small dimensions is an enhancement on the Reduced Length Buckling Restrained Braces (RL-BRBs), consists of steel core and additional tensile elements embedded in a concrete encasement. Employing tensile elements in this composite fuse with a new configuration enhances the energy dissipation efficiency and removes the tensile strength limitations that exist in bracing elements that contain RL-BRBs. Here, the optimal length of the CBRF is computed by considering the anticipated strain demand and the low-cyclic fatigue life of the core under standard loading protocol. An experimental program is conducted to explore the seismic behavior of the suggested CBRF compare with an RL-BRB specimen under gradually increased cyclic loading. Moreover, Hysteretic responses of the specimens are evaluated to calculate the design parameters such as energy dissipation potential, strength adjustment factors, and equivalent viscous damping. The findings show that the suggested fuse possess a ductile behavior with high energy absorption and sufficient resistance and a reasonably stable hysteresis response under compression and tension.

An Experimental Study on the Basic Properties of Penetrating repair material using Silicate-based Inorganic Materials (규산염계 무기 재료를 활용한 침투성 보수재의 기초 특성에 관한 실험적 연구)

  • Ha, Sang-Woo;Oh, Sung-Rok;Choi, Yung-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.39-45
    • /
    • 2017
  • In this study, permeable repair materials mainly composed of silicate - based inorganic materials(SIM), which are easily available domestically, were prepared as a basic study for the development of permeable repair materials using SIM. SIM were compared and examined for their performance as repair materials by selecting a product group which has many cases of use in foreign countries. The SIM used were mainly composed of sodium, potassium and lithium silicate. Performance evaluation of SIM was performed by absorption and penetration, compression and adhesion, rapid chloride ion penetration, rapid freezing and thawing, and chemical resistance test. According to the test results, SIM showed effective performance in all areas, mainly because SIM permeates into the interior of the capillary and has a dense internal microstructure. Therefore, it can be used variously to improve the durability of concrete based on the results of this experiment.

A Study of Engineering Properties of Rock Mass Weathered by Sea water (해수에 의한 암반 풍화의 공학적 특성 연구)

  • Choi Kang-Il;Kang Coo-Won;Go Chin-Surk
    • Explosives and Blasting
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • This study is to clarify the comparative relationship and mechanical anisotropy of granite distributed in the Nam-weon on the subject of weathered rock mass sea water surroundings. Artificial weathering test is defined as a test, which controls the weathering rate and agents by controlling the weathering rate and agents by artificial environmental of salt water. Increased weathering degree is large indicated by weathering salt water, such as apparent specific gravity, absorption, porosity, uniaxial compression strength, P-wave velocity, slake durability, shore hardness, indirect tensile strength(brazilian test) and cohesion were measured. As the Weathering salt water proceeds, cracks develope increasingly. A number the cracks affect the rock deformation. Therefore, stress-strain curve of weathered salt water rock in one confined state are quite differ from weathered fresh water rock those. A reason of their deformation type is the formation of micro-cracks and potential porosity caused by artificial weathering test.

Resistance of Web-Separated Diagrid Nodes Subjected to Cyclic Loading (반복하중에 대한 웨브전이형 다이아그리드 노드의 구조적 특성)

  • Kim, Young Ju;Jung, In Yong;Ju, Young K.;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.257-266
    • /
    • 2009
  • The results of the analysis of the structural behavior of diagrid nodes that were subjected to cyclic loads such as wind and earthquakes was not fully understood due to difficulties in considering the welding type. In this study, diagrid nodes were tested to determine their behavior when they are subjected to seismic or wind loads. Five specimens were designed and fabricated. The corresponding test parameters were the welding type for each point and the length of the overlap of the side stiffener and the brace web. Tensile force was applied to one diagrid brace member, and compression force was applied to the other diagrid brace member. Cyclic loading was applied until the failure. The test showed that failures are due to axial stress from axial force and the additional bending moment of the two combined axial forces that have different directions. Tensile failure was observed from the tensile force, and local buckling was observed from the compressive force at the flange of the brace member. In addition, the welding type and the length overlap affected the initial stiffness, the yielding stress, and the energy absorption of the diagrid node.

Evaluation of Load-Carrying Capacity Loss due to Corrosion in Thin-Walled Section Steel Members (판폭두께비가 큰 휨부재의 부식발생에 따른 구조성능평가에 관한 연구)

  • Chung, Kyung Soo;Park, Man Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.619-626
    • /
    • 2009
  • The use of thin-walled flexural members has proven to be a practical way to achieve the lowest cost in the construction of prefabricated long-span, low-rise building frames in steel. On the other hand, most of these structures are subjected to corrosion due to environmental exposure, which can reduce their carrying capacity. Corrosion damage is a serious problem for these structures as it causes thickness loss. That is, the class of a section (plastic, compact, non-compact, or slender) may change from one to another due to the loss of thickness of the compression flange and web due to corrosion. In this study, the effects of corrosion on thin-walled members in long-span steel frames were evaluated with regard to the moment-rotation curve, initial stiffness, maximum load capacity, stiffness in the post-maximum capacity, and energy absorption.

Studies on the Physical and Mechanical Properties of Imported and Domestic Corks (수입(輸入)코르크와 국산(國産)코르크의 물리(物理)·기계적(機械的) 성질(性質)에 관(關)한 연구(硏究))

  • Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.45-54
    • /
    • 1993
  • This study examines the differences in structures, physical and mechanical properties between domestic(Quercus variabilis Blume) and foreign(Quercus suber L.) corks. The results obtained are as follows: 1. The cork tissue consists of cork cells, lenticels, sclereids and dark-brown zone. There was a significant difference in ratio of cork cells between foreign cork(93 %) and domestic cork(87 %). The ring width and width of late cork of the foreign cork were wider than those of domestic cork. But the percentage of late cork of domestic cork was richer than that of foreign cork. The size of cork cell of foreign cork was larger by about two times than that of domestic cork. 2. The density was slightly higher in domestic cork(0.22 g/$cm^3$) than in foreign cork(0.19 g/$cm^3$). During first 24 hours, the amount of water absorption of the foreign cork was greater than that of domestic cork. However, after 24 hours, the tendency was reversed. The level of EMC was higher in domestic cork than in foreign cork. Total shrinkage in the radial and tangential directions was larger in domestic cork than tn foreign cork. In the longitudinal direction, the tendency was reversed. There was no difference in total swelling in three woody directions between the two corks. 3. The modulus of elasticity in compression in the logitudinal and tangential direction was higher in domestic cork than in foreign cork, but the tendency was reversed in the radial direction. Both corks showed 95% of recovery rate after 24 hours when they were compressed by 0.5. There were no differences in tension strength and Brinell,s hardness bet ween domestic and foreign corks.

  • PDF

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-I - Preparation and pharmaceutical evaluation of controlled release acetaminophen tablets-

  • Shim, Chang-Koo;Kim, Ki-Man;Kim, Young-Il;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.151-160
    • /
    • 1990
  • In order to develop a controlled-release oral drug delivery system (DDS) which sustains the plasma acetaminophen (AAP) concentration for a certain period of time, microporous membrane-coated tablets were prepared and evaluated in vitro. Firstly, highly water-soluble core tablet of AAP were prepared with various formulations by wet granulation and compression technique. Then the core tablets were coated with polyvinychloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of core tablets and coating suspensions on the pharmaceutical characteristics such as drug release kinetics and membrane stability of the coated tablets was investigated in vitro. AAP was released from the coated tablets as a zero-order rate in a pH-independent manner. This independency of AAP release to pH change from 1.2 to 7.2 is favorable for the controlled oral drug delivery, since it will produce a constant drug release in the stomach and intestine regardless of the pH change in the GI tract. Drug release could be extended upto 10 h according to the coating condition. The release rate could be controlled by changing the formula compositions of the core tablets and coating suspensions, coat weight per each tablet, and especially PVC/sucrose ratio and particle size of the sucrose in the coating suspension. The coated tablets prepared in this study had a fairly good pharmaceutical characteristics in vitro, however, overall evaluation of the coated tablet should await in vivo absorption study in man.

  • PDF

Effect of Kenaf Fiber Loading on the Properties of Natural Fiber/Natural Rubber Composites (천연섬유/천연고무 복합재료의 특성에 미치는 Kenaf 섬유함량의 영향)

  • Cho, Yi-Seok;Cho, Dong-Hwan
    • Elastomers and Composites
    • /
    • v.46 no.3
    • /
    • pp.186-194
    • /
    • 2011
  • Natural fiber/natural rubber composites were fabricated by uniformly compounding natural rubber and cellulose- based natural fiber kenaf and then by compression molding. The effect of kenaf fiber content on their vulcanization behavior, hardness, tensile properties, tear strength and static and dynamic properties was investigated. The contents of kenaf fiber in the composites were 0, 5, 10, 15, and 20 phr, compared to natural rubber and additives. The result indicated that various properties of natural rubber depended on the kenaf fiber content. With increasing kenaf fiber content, the torque for vulcanization of natural rubber was increased whereas the vulcanization time was reduced as well. The hardness, tensile modulus and tear strength of kenaf/natural rubber composites were gradually decreased with the fiber content whereas the tensile strength and elongation at break were decreased. Also, with increasing the kenaf fiber content the dynamic property of natural rubber was changed more greatly than the static property. The loss factor, which is closely related with the damping or absorption of the energy given to natural rubber, was proportionally increased with the fiber content.

Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements (조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성)

  • Shin, Seung-Hoon;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.72-84
    • /
    • 2016
  • The conventional brace system is generally accepted as the lateral load resisting system for steel structures due to efficient story drift control and economic feasibility. But lateral stiffness of the structure decreases when buckling happens to the brace in compression, so that it results in unstable structure with unstable hysteresis behavior through strength deterioration. Buckling restrained brace(BRB) system, in which steel core is confined by mortar/concrete-filled tube, represents stable behavior in the post-yield range because the core's buckling is restrained. So, seismic performance of BRB is much better than that of conventional brace system in point of energy absorption capacity, and it is applied the most in high seismicity regions as damper element. BRBs with various shaped-sections have been developed across the globe, but the shapes experimented in Korea are now quite limited. In this study, we considered built-up type of restraining member made up of precast reinforcement concrete and the steel core. we experimented the BRB according to AISC(2005) and evaluated seismic performances and hysteresis characteristics.