• Title/Summary/Keyword: Compression Fracture

Search Result 579, Processing Time 0.036 seconds

Analyses of the Decrease Phenomenon of Fracture Resistance Curve Under Tension-Compression Loading (인장-압축하중 하의 파괴저항곡선의 감소현상 해석)

  • Yun, Byeong-Gon;Seok, Chang-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.378-385
    • /
    • 2000
  • Fracture resistance (J-R) curves, which are used for elastic-plastic fracture mechanics analyses, decreased under tension-compression loading condition. This phenomenon was proved by several former researches, but the causes have not been clear yet. The objective of this paper is to investigate the cause of this phenomenon. On the basis of fracture resistance curve test results, strain hardening hypothesis, stress redistribution hypothesis and crack opening hypothesis were built. In this study, hardness tests, Automated Ball Indentation(ABI) tests, theoretical stress field analyses, and crack opening analyses were performed to prove the hypotheses. From this study, strain-hardening of material, generation of tensile residual stress at crack tip, and crack opening effects are proved as the causes of the decrease hypothesis.

A Case Report on Burning Acupuncture Treatments for Stable Compression Fracture (화침을 이용한 흉요추부 압박골절 치험 1례)

  • Lee, Jong-Soo;Han, Soon-Hyun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.3 no.1
    • /
    • pp.167-174
    • /
    • 2002
  • Stable compression fractures are most often caused by trauma as traffic accidents. Stable compression fractures can refer pain to the mid-back, which is characterized by the pain in the thoracolumbar spinous prosess. recently we experienced a 19 years old man who had lumbago originating from Stable compression fractures and condition was improved through burning acupunture.

  • PDF

Fracture Characteristics of Carbonized Silicon Grinding Wheels (탄화규소 연삭숫돌의 파괴특성)

  • Oh, Dong-Seuk;Lee, Byong-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.45-51
    • /
    • 2002
  • In this study, the fracture characteristics of carbonized silicon grinding wheels were examined with tensile, compression, impact and bending test. The experiment was performed for the various grinding wheels with grain size #46, #80, and grade H, L, P, and one vitrified bond and one structure No.7. Also the centrifugal fracture rpm of carbonized silicon grinding wheels were measured and compared with the calculated values for the various wheel diameters and thicknesses. The results showed that the fracture tensile strength was $1.5~2.0Kg_f/mm^2$, and it was increased by decreasing grain size and increasing grade. The fracture compression loads were $1,600~3,000Kg_f$, and the inner stress was higher than outer's. And the absorption energy of impact test was 3.3~4.7 J, and it was increased by decreasing grain size but it was not effected by grade. The fracture bending stress was $0.1~0.2Kg_f/mm^2$, and it was increased by decreasing grain size and increasing grade. The centrifugal fracture rpm of carbonized silicon grinding wheel was about 8,500~12,000 and agreed well with the calculated value, and it was increased by decreasing diameter. However, it was almost constant for the reduction of wheel thickness.

Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation

  • Park, Jin-Woo;Kim, Kyoung-Tae;Sung, Joo-Kyung;Park, Seong-Hyun;Seong, Ki-Woong;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.498-503
    • /
    • 2017
  • Objective : The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. Methods : We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. Results : The mean compression pressures of the 40- and 45-mm long cannulated lag screws were $50.48{\pm}1.20N$ and $53.88{\pm}1.02N$, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was $52.82{\pm}2.17N$, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure ($60.68{\pm}2.03N$) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Conclusion : Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

Localized Necking in a Round Tensile Bar for a HCP Material Considering Tension-compression Asymmetry in Plastic Flow (소성 비대칭성을 갖는 HCP 소재의 국부변형 및 네킹해석)

  • Yoon, J.H.;Lee, J.H.
    • Transactions of Materials Processing
    • /
    • v.21 no.5
    • /
    • pp.285-290
    • /
    • 2012
  • In spite of progress in predicting ductile failure, the development of a macroscopic yield criterion to describe damage evolution in HCP (hexagonal close-packed) materials remains a challenge. HCP materials display strength differential effects (i.e., different behavior in tension versus compression) in their plastic response due to twinning. Cazacu and Stewart(2009) developed an analytical yield criterion for porous material containing randomly distributed spherical voids in an isotropic, incompressible matrix that shows tension-compression asymmetry. The goal of the calculations in this paper is to investigate the effect of the tension-compression asymmetry on necking induced by void nucleation, evolution and consolidation. In order to investigate the effect of the tension-compression asymmetry of the matrix on necking and fracture initiation, three isotropic materials A, B, and C were examined with different ratios of tension-compression asymmetry. The various types of material had BCC, FCC, and HCP crystal structures, respectively. The ratio between tension and compression in plastic flow significantly influences the fracture shape produced by damage propagation as well as affecting the localized neck.

Quantification of Localized Fracture Mechanism of Recycled Aggregate Concrete in Compression using Acoustic Emission Technique (음향방출기법을 이용한 순환골재 콘크리트의 압축파괴 기구의 정량화)

  • Kim, Sun-Woo;Yun, Hyun-Do;Kim, Yun-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.87-94
    • /
    • 2007
  • Reuse of recycled aggregate from demolished concrete structure is beneficial and necessary from the viewpoint of environmental preservation and effective utilization of resources. The most important mechanical properties of recycled aggregate concrete (RAC) are the compressive strength, the tensile and the flexural strengths, the bond strength and the elastic modulus of such concrete. In particular, the stress-strain relation and fracture process of RAC in compression is especially important in theoretical and numerical analysis as well as engineering design of RAC structures. In this paper, to clarify the characteristics of fracture process in RAC, acoustic emission(AE) method is applied to detect micro-cracking in concrete under compression. From AE parameters, it is found that cracking and fracture behaviors in recycled aggregate concrete fairly differ from that of normal and recycled sand concrete.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Pain Relief and Associated Factors after a Kyphoplasty for Treating an Osteoporotic Vertebral Compression Fracture (골다공증성 척추 압박 골절에서 풍선 척추 성형술 후 통증의 호전 및 관련 요인에 대한 분석)

  • Koh, Young Do;Kim, Dong Jin
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.186-191
    • /
    • 2014
  • Purpose: The objectives of this study were to assess pain relief according to the time after kyphoplasty and to evaluate the factors affecting pain relief after kyphoplasty in the treatment of a single-level osteoporotic vertebral compression fracture. Methods: A retrospective review of 34 kyphoplasties for single-level osteoporotic vertebral compression fractures was performed. Pain relief was assessed by using the visual analogue scale (VAS) at preoperatively and postoperatively at 6 weeks, 3 months, and 6 months. Associated factors, including age, sex, pain duration, bone mineral density, and cement leakage, were evaluated using the patients' medical records. Statistical analyses were conducted using the paired t-test to assess pain relief and using the independent t-test and Pearson's correlation coefficient to evaluate the relationship between those factors and pain relief. Results: Preoperatively, the mean VAS score was 7.06. Postoperatively, it declined to 3.66 (p=0.001), 2.81 (p=0.001) and 2.24 (p=0.001) at 6 weeks, 3 months and 6 months, respectively. Also, statistically significant pain relief was observed during the periods from 6 weeks to 3 months (p=0.001) and from 3 months to 6 months (p=0.001). However, reduction of the VAS score showed no significant correlation with age, sex, pain duration, bone mineral density, or cement leakage (p>0.05). Conclusion: Our study suggests that a kyphoplasty may be effective in osteoporotic vertebral compression fracture patients with acute pain and that after the kyphoplasty, pain is reduced remarkably for 6 weeks and then continuously for 6 months.

A Case Report of Integrative Korean Medicine Treatment of a Patient with a Compression Fracture Arising from Metastasis of Prostate Cancer to the Spine (전립선암의 척추전이로 인해 압박골절이 발생한 환자에 대한 한방처치 1례)

  • Kim, Seok-woo;Kim, Soo-yeon;Kim, Dong-woo;Kang, Kyung-rae;Ha, Do-hyung;Kim, Soo-yeon;Oh, Seung-ju;Jin, Dong-eun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.5
    • /
    • pp.841-850
    • /
    • 2019
  • Objective: The aim of this study was to report the effects of traditional Korean medicine as a treatment for the pain of a compression fracture in a patient with metastatic prostate cancer. Methods: A 60-year-old male patient with a compression fracture was treated with herbal medicines, acupuncture, and pharmacopuncture for 25 days. His chief complaints were severe low back pain, pain and numbness in both legs, and right groin pain. The effect of treatment was evaluated by the numerical rating scale (NRS) score for pain, the Oswestry Disability Index (ODI) score, and blood test results (CBC-diff count, CRP, ESR, etc.). Results: After 25 days of inpatient treatment, the patient's pain was controlled. The NRS and ODI scores were lower and most pathological symptoms had decreased. Conclusions: Traditional Korean medicine can be a solution for patients with compression fractures arising from metastasis of prostate cancer to the spine.

Cauda Equina Syndrome after Percutaneous Balloon Kyphoplasty for Pathologic Compression Fracture (병적 척추체 압박 골절 환자에서 경피적 풍선 척추 성형술 시행 후 발생한 마미 증후군)

  • Park, Sung Jun;Park, Myung Hoon;Park, Jae Woo;Cho, Kyu Jung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.90-94
    • /
    • 2020
  • Percutaneous balloon kyphoplasty is an option for pain relief in pathological vertebral compression fractures. Complications related to cement leakage through cortical defects have been reported. On the other hand, dural compression due to retropulsion of the tumor mass is rarely reported. The authors report a case of a 65-year female patient who had cauda equina syndrome after a percutaneous balloon kyphoplasty in a pathological vertebral fracture, even though epidural compression were not found prior to surgery. Magnetic resonance imaging revealed retropulsion of the tumor mass into the spinal canal through the disrupted posterior vertebral cortex.