Wavelet Compression Method with Minimum Delay for Mobile Tele-cardiology Applications (이동형 Tele-cardiology 시스템 적용을 위한 최저 지연을 가진 웨이브릿 압축 기법)

  • Kim Byoung-Soo;Yoo Sun-Kook;Lee Moon-Hyoung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.786-792
    • /
    • 2004
  • A wavelet based ECG data compression has become an attractive and efficient method in many mobile tele-cardiology applications. But large data size required for high compression performance leads a serious delay. In this paper, new wavelet compression method with minimum delay is proposed. It is based on deciding the type and compression ratio(CR) of block organically according to the standard deviation of input ECG data with minimum block size. Compression performances of the proposed algorithm for different MIT ECG Records were analyzed comparing other ECG compression algorithm. In addition to the processing delay measurement, compression efficiency and reconstruction sensitivity to error were also evaluated via random noise simulation models. The results show that the proposed algorithm has both lower PRD than other algorithm on same CR and minimum time in the data acquisition, processing and transmission.

A Study on the Equi-biaxial Tension Test of Rubber Material (고무재료의 등 이축 인장시험에 관한 연구)

  • 김완두;김동진;김완수;이영신
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.95-104
    • /
    • 2003
  • The material properties of rubber was determined by the experiments of uniaxial tension, uniaxial compression, planer tension, equi-biaxial tension and volumetric compression. In compression test, it is difficult to obtain the pure state of compression stress and strain due to friction force between the specimen and compression platen. In this study, the stress and strain data from the equi-biaxial tension test were converted to compression stress and strain and compared to a pure state of simple compression data when friction was zero. The compression test device with the tapered platen was proposed to overcome the effect of friction. It was fumed out that the relationship of the stress and strain using the tapered platen was in close agreement with the pure compressive state.

Power Quality Data Compression using Wavelet Transform (웨이브렛 변환을 이용한 전력품질 데이터 압축에 관한 연구)

  • Chung Young-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.561-566
    • /
    • 2005
  • This paper introduces a compression technique for power qualify disturbance signal via discrete wavelet transform(DWT). The proposed approach is based on a previous estimation of the stationary component of power quality disturbance signal, so that it could be subtracted from the original signal in order to reduce a dynamic range of signal and generate transient events signal, which is subsequently applied to the compression technique. The compression techniques is performed through the difference signal decomposition, thresholding of wavelet coefficients, and signal reconstruction. It presents the relation between compression efficiency and threshold. It shouts that the wavelet transform leads to a power quality data compression approach with high compression efficiency, small compression error and good de-nosing effect.

Performance Characteristics of a Household Refrigerator with Dual Evaporators Using Two-Stage Compression Cycle

  • Joo, Young-Ju;Kim, Young-Heon;Lee, Moo-Yeon;Yoon, Won-Jae;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2009
  • The objective of this study is to investigate performance characteristics of a household refrigerator using a two-stage compression cycle. The performance of the two-stage compression cycle was measured by varying the compressor speed, condensing temperature, and evaporating temperature. The COP of the two-stage compression cycle was analyzed and then compared with that of the single-stage compression cycle. The optimum combination of compressor speeds for a low- and a high-stage was determined. The COP of the two-stage compression cycle using a PTC (parallel two-stage compression) method was 5.85% higher than that of a STC (serial two-stage compression) method at optimum operating conditions.

Optimization of compression ratio in closed-loop CO2 liquefaction process

  • Park, Taekyoon;Kwak, Hyungyeol;Kim, Yeonsoo;Lee, Jong Min
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2150-2156
    • /
    • 2018
  • We suggest a systematic method for obtaining the optimal compression ratio in the multi-stage closed-loop compression process of carbon dioxide. Instead of adopting the compression ratio of 3 to 4 by convention, we propose a novel approach based on mathematical analysis and simulation. The mathematical analysis prescribes that the geometric mean is a better initial value than the existing empirical value in identifying the optimal compression ratio. In addition, the optimization problem considers the initial installation cost as well as the energy required for the operation. We find that it is best to use the fifth stage in the general closed-loop type carbon dioxide multi-stage compression process.

Implement of Integration Compression Environment System Compressing Medical Images (의료영상 압축을 위한 통합압축환경시스템 구현)

  • 추은형;박무훈
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.1
    • /
    • pp.142-148
    • /
    • 2003
  • We compress medical images in order to solve problems both of request of storage mediums and of a low network speed. In this paper, integration compression environment has been developed for unity of various compression methods. Various compression methods that are implemented by integration compression environment, RLC, Lossless JPEG, and JPEG, comply with the DICOM 3.0. A compression method using DWT is implemented at it. And a unit method of Lossless compression method and lossy compression method is designed to improve images quality and to progress compression ratio. Diverse medical images can be compressed by each compression method. And integration compression environment is operated together database so that information of medical images is administered.

A Study for Efficiency Improvement of Compression Algorithm with Selective Data Distinction (선별적 데이터 판별에 의한 압축 알고리즘 효율 개선에 관한 연구)

  • Jang, Seung Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.902-908
    • /
    • 2013
  • This paper suggests to compress data selectively for improvement of data compression efficiency, not to perform unconditional compression on data. Whether to compress or not is determined by selective data distinction. By doing so, we can avoid unnecessary compression in the case of low compression efficiency. Cutting down the unnecessary compression, we can improve the performance of the pre-compression algorithm. Especially, the data algorithm which was already compressed could not be compressed efficiently in many cases, even if apply compression algorithm again. Even in these cases, we don't have to compress data unnecessarily. We implemented the proposed function actually and performed experiments with implementation. The experimental results showed normal operation.

Comparison of Medical Compression Garments by Manufacturing Country (의료용 화상환자 압박복의 제조 국가별 비교)

  • Cho, Shin-Hyun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.4
    • /
    • pp.31-39
    • /
    • 2015
  • A special medical compression garment has been developed to be worn after surgery or treatment using an elastic fiber in which the amount of compression can be adjusted to a specified targeted area to reduce the formation of hypertrophic scarring. In order to develop this medical compression garments, specialized technical skill in fiber, compression class and body measurements are needed. This study provides product survey data for the development of medical compression garments. An investigation analyzed medical compression garments of 16 brands from 6 countries sold in the Korean market & online, such as Make Me Heal, Jobst, Bio Concepts, Design Veronique$^{(R)}$ Nouvelle and Leonisa$^{(R)}$ (USA), Respire(Germany), Malcom$^{(R)}$, Holistic garments and Jobskin(UK), Technomed, kanav Healthcare and Sindhoori surgicals(India), Soo medical and C&C medical(Korea), Secondskin(Australia). The main fibers of compression garments were nylon and spandex: in addition, the fiber content was different by country and brand. The number of compression classes of products was USA(4), UK(4), and India(4). For body measurements, USA and many brands used (bust, under bust, waist, hip, thigh, knee, calf, ankle, upper arm, elbow, wrist, armhole bicep) circumference and length.

  • PDF

A Study on the Molding Characteristics of Injection Compression Molding Through Computer Simulation (컴퓨터 해석을 통한 사출압축성형의 성형특성에 관한 연구)

  • Chun, Y.H.;An, H.G.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.47 no.4
    • /
    • pp.341-346
    • /
    • 2012
  • Injection molding is one of the widely used polymer processing operations. It is being used for not only conventional injection molding but gas injection molding, water injection molding, and injection compression molding. Injection compression molding involves injection and compression operation, and it gives uniform physical property and high dimensional quality of product. In this study, injection compression characteristics for various product shapes have been investigated by computer simulation. Product containing side wall showed not much effective in injection compression molding since wall thickness direction was perpendicular to the compression direction. Uniform and low shrinkage was observed in injection compression molding comparing conventional injection molding. Subsequently injection compression molding can be used for molding precise product. Optimal injection compression molding condition was obtained using design of experiment for plastic lens and the results were compared with conventional injection molding.

Comparison of quality of 30:2 vs. 2:30 CPR in manikins (심폐소생술 방법 변화에 따른 quality 비교 - 30:2와 2:30 비교분석실험 -)

  • Uhm, Tai-Hwan;Yoou, Soon-Kyu;Choi, Hea-Kyung;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.71-81
    • /
    • 2010
  • Purpose: To minimize an interruption in chest compression, reduce the hands-off time, the American Heart Association has recommended the ratio of chest compression to ventilation ratio to 30:2 from 2005 CPR guideline to 2010 CPR guideline. However, current studies have shown that the hands-off time was > 10 seconds with that method. For this reason, we devised new CPR method that a ventilation to chest compression ratio of 2:30 to reduce pt assessment time and skipped the assessment step of carotid artery pulse would be a more effective way to reduce the hands-off time & the time to set the CPR. According to the more detailed purpose are listed below. 1) We would like to confirm efficiency of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 to reduce the hands-off time & the time to set the CPR. 2) We would like to evaluate possibility of increasing for chest compression accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 3) We would like to evaluate possibility of increasing for ventilation accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 Methods: According to 2005 American Heart Association Guidelines, 60 paramedic students(20 students X freshmen, sophomore, junior) performed 5 cycles of 3~ chest compressions : 2 ventilations after A, B, C evaluation with Laerdal Resusci R Anne SkillReporters. After 5 minutes rest, the 60 students performed 5 cycles of 2 ventilations : 30 chest compressions after A, B evaluation with the manikins between 13 and 17 September 2010. The short reports including speed & accuracy of chest compression, respiratory, CPR cycle were gained from the manikins. Hands-off times were measured by assistants. Results: Recently, the importance of high quality CPR was emphasized in order to perform the CPR faster and more accurate. To find out improving the conventional CPR method, we switch the procedure of the compression and the ventilation. By switching the procedure back and forth, we are able to compare the effectiveness of CPR between two type of CPR method which are 2:30 and 30:2 methods. 2:30 is that the breaths is delivered twice, first and perform 30 compressions while 30:2 perform 30 compressions first and give 2 breaths followed by the ABC method. Also, we verify the effectiveness of the hands off time, compression accuracy of the compression through the comparison of the two procedure as mentioned earlier. Consequently research verified that 2:30 is the efficient by providing faster set up delivering more accurate chest compression. Conclusion: 2:30 can minimize a time delay from cardiac standstill until starting the chest compression. In addition, hands-off time which is an interruption in chest compression can be shortened by 2:30 method, which result to effective oxygenation of coronary artery & maintenance of the bloodstream. Once again, performing the 2:30 method provide lessen hands off time and increase the accuracy of the chest compression.

  • PDF