• Title/Summary/Keyword: Compound Source

Search Result 449, Processing Time 0.026 seconds

A Preliminary Study on the Application of Compound Sources to Active Noise Barrier (복합음원이 적용된 능동방음벽에 관한 선행 연구)

  • Baek, Kwang-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.42-48
    • /
    • 2011
  • This preliminary study is about the application of the compound source to the active noise barrier system as control sources. A compound source is composed of two monopole sources but having opposite phase. However, both monopole sources in one compound source are not independently controlled. The source strength of monopole source close to the noise source is proportional to the other one. Therefore, the cost for the hardware system is cheaper than usual system but known to possibly having a similar performance in generating anti-noise acoustic field. In this study, using a simple active noise barrier system model having a non-reflective floor, the effectiveness of the system with compound sources is investigated through computer simulations and shows 30~40 % performance improvement of noise reduction.

A study on cooling characteristics of clathrate compound for cold storage applications (저온축열용 포접화합물에 냉각특성에 관한 실험적 연구)

  • 한영옥;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

The Study on the Performance of the Fuel Cell Driven Compound Source Hybrid Heat Pump Heating and Cooling System to Large Community Building (대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 냉.난방 시스템 성능 해석)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.82-87
    • /
    • 2007
  • In the present study, the simulation on the annual performance evaluation of a renewable energy systems with fuel cell driven compound source hybrid heat pump systems is applied to the heating and cooling of large community building. The large community building has the economical advantage to apply heat pump cooling and heating systems the long period operation. If air and ground source hybrid heat pump systems are combined, COP of the system can be increased largely. Fuel cell driven compound source hybrid heat pump system can reduced the fuel cost as well as thermal storage tank sharply.

  • PDF

Active Control of Vibrational Intensity in a Compound Vibratory System (복합진동계의 진동 인텐시티 능동 제어)

  • Kim, Gi-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.109-118
    • /
    • 2002
  • The vibrational intensity and the dynamic response of a compound vibratory system had been controlled actively by means of a feedforward control method. A compound vibratory system consists of a flexible beam and two discrete systems - a vibrating source and a dynamic absorber. By considering the interactive motions between discrete systems and a flexible beam, the equations of motion for a compound vibratory system were derived using a method of variation of parameters. To define the optimal conditions of a controller the cost function, which denotes a time averaged power flow, was evaluated numerically. The possibility of reductions of both of vibrational intensity and dynamic response at a control point located at a distance from a source were fecund to depend on the positions of a source, a control point and a controller. Especially the presence of a dynamic absorber gives the more reduction on the dynamic response but the less on the vibrational intensity than those without a dynamic absorber.

Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building (대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Jeong, Dong-Hwa;Byun, Jae-Ki;Choi, Young-Don;Cho, Sung-Hwan
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

PAHs Source Fingerprints for Municipal Incinerator, Motor Vehicle Fuels and Industrial Boilers Emission (발생원별에 따른 PAHs 배출특성)

  • 박찬구;윤중섭;김민영;손종열;모세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.331-343
    • /
    • 2004
  • The results of individual PAH source profiles that can be applied to receptor model are as follows. The sum of 16 PAH concentrations was 391.41 ng/S㎥ in a tunnel. Phenanthrene was the most abundant compound among 16 PAH, and then pyrene, fluoranthene, anthracene, and naphthalene can be seen in elevated contents. 11,056.61 ng/S㎥ of 16 PAH concentrations in BC oil boiler was two times higher than 6,582.57 ng/S㎥) of those in LNG boiler. Naphthalene was the most abundant compound in both facilities. Phenanthrene, anthracene, and acenaphthylene were the second dominant compound group in order from both facilities. BC oil boiler had relatively high concentration of pyrene compared to LNG boiler that had high concentration of fluorene and did not detect pyrene. The sum of 16 PAH concentrations emitted from MSW incinerators after APCD (air pollution control device) was three times higher than those from MSW incinerators before APCD. However, the concentrations of more than 4-ring PAH compounds (e.g., benzo (a)anthracene) before APCD were higher than those after APCD. This fact implies that PAHs generated by combustion process are eliminated in APCD and they are continuously produced in stack or atmosphere by PAHs precursors.

Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building (대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Lee, Jong-Gil;Hong, Seong-Ho;Choi, Young-Don;Cho, Sung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

Voltage Control of a Synchronous Generator for Ship using a Compound Type Digital AVR (혼합형 디지털 자동 전압 조정 장치를 이용한 선박용 동기발전기의 출력전압제어)

  • Park, Sang-Hoon;Lee, Sang-Seuk;Yu, Jae-Sung;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.397-403
    • /
    • 2009
  • In this paper, an exciter current control of a synchronous generator for ships using a compound type digital automatic voltage regulator (DVAR) in order to provide a constant output voltage of the generator is presented. The compound type DAVR is composed of a controller part to adjust output voltage and an power source unit to supply power to the exciter. The controller part, which generates the PWM switching pattern via the PI controller, drives a power MOSFET for bypass to limit the SG's exciter current. The power source unit part is parallel connected to an output terminal of the generator through a reactor and a power CT. The residual magnetic flux of SG provides exciter current to the exciter through the reactor during the initial running or no load state and load current supplies field current to the exciter through the power CT during loading state. This paper confirmed an experiment to verify the validity of compound type DAVR system for controlling output voltage of synchronous generator.

A Study on the Supercooling Improvement of TMA -Clathrate Compound by Ethanol (에탄올에 의한 TMA- 포접화합물의 과냉각 개선에 대한 연구)

  • Kim, Jin-Heung;Chung, Nak-Kyu;Kim, Chang-Oh
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.392-397
    • /
    • 2005
  • This study is investigated the supercooling improvement and the phase change temperature of the TMA clathrate compound including TMA(Tri-Methyl-Amine, ($(CH_3)_3N$) of 25 wt% with additive as a low temperature storage material at $6^{\circ}C$ and $-7^{\circ}C$ of heat source. The additive is ethanol of 0.1, 0.3 wt% and 0.5 wt%. The results showed that as the concentration of ethanol is increased, the phase change temperature, the degree of supercooling and the retention time of liquid phase are decreased. Especially, TMA 25 wt% clathrate compound with ethanol of 0.5wt% has the average of phase change temperature of $3.8^{\circ}C$, degree of supercooling of $0.9^{\circ}C$, $0.8^{\circ}C$ and retention time of liquid phase for 6, 5 minutes at $-6^{\circ}C$, $-7^{\circ}C$ of heat source. From the results of this study, TMA 25wt% clathrate compound with ethanol 0.5wt% showed supercooling repression effect.

  • PDF

A Study on Supercooling Repression of TMA-Water Clathrate Compound II (TMA-물계 포접화합물의 과냉각 억제에 대한 연구 II)

  • Kim Chang-Oh;Kim Jin-Heung;Chung Nak-Kyu
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2006.05a
    • /
    • pp.317-324
    • /
    • 2006
  • This study aims to find out cooling characteristics of TMA(Tri-Methyl-Amine, ($CH_{3})_{3}N$) 25wt%-clathrate compound with ethanol($CH_{3}CH_{2}OH$) such as supercooling, phase change temperature and specific heat. For this purpose, ethanol is added as per weight concentration and cooling experiment is performed at $-6{\sim}-8^{\circ}C$, cooling heat source temperature, and it leads the following result. (1) Phase change temperature is decreased due to freezing point depression phenomenon. Especially, it is minimized as $3.8^{\circ}C$ according to cooling source temperature in case that 0.5w% of ethanol is added. (2) If 0.5wt% of ethanol is added, average supercooling degree is $0.9^{\circ}C $ and minimum supercooling is $0.8,\;0.7^{\circ}C$ according to cooling heat source temperature. The restraint effect of supercooling is shown. (3) Specific heat shows tendency to decrease if ethanol is added. It is $3.013{\sim}3.048\;kJ/kgK$ according to cooling heat source temperature if 0.5wt% of ethanol is added. Phase change temperature higher than that of water and inhibitory effect against supercooling can be confirmed through experimental study on cooling characteristics of TMA 25wt%-water clathrate compound by adding additive, ethanol. This can lead to shorten refrigerator operation time of low temperature thermal storage system and improve COP of refrigerator and efficiency of overall system. Therefore energy can be saved and efficiency can be improved much more.

  • PDF