• 제목/요약/키워드: Composite deck slab

검색결과 105건 처리시간 0.025초

탄소섬유 Rod로 성능향상된 교량 바닥판의 피로거동 (The Fatigue behavior of strengthened bridge deck with Carbon Fiber Rod)

  • 심종성;김민수;김영호;주민관
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.313-318
    • /
    • 2002
  • The use of carbon fiber rods is a promising technology of increasing flexural and shear strength of deficient reinforced concrete members. The purpose of this experimental study is to investigate the fatigue behavior and strengthening effects of the strengthened bridge deck with isotropic and othortropic carbon fiber rod. This study shows a fatigue loading, compliance and S-N Curve between strengthened isotropically and othortropically. Then estimate the effective fatigue behavior of RC slab using composite rods that are inserted in high special purposed polymer mortar.

  • PDF

시공중인 합성바닥슬래브의 처짐보정에 대한 수치적 연구

  • 김영찬;이정헌
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.293-298
    • /
    • 2002
  • In the composite deck system, beams and deck plates deflect during construction. This lens-shaped deflection may cause problems in the serviceability of a building. Therefore, it should be compensated to be level. Several methods for leveling of floor slab are available, such as increasing stiffness of structural members, pouring additional concrete. In this study, additional weight and volume o( concrete for level compensation are examined for various size of floors.

  • PDF

A design approach of integral-abutment steel girder bridges for maintenance

  • Kim, WooSeok;Jeong, Yoseok;Lee, Jaeha
    • Steel and Composite Structures
    • /
    • 제26권2호
    • /
    • pp.227-239
    • /
    • 2018
  • Integral abutment bridges (IABs) have no joint across the length of bridge and are therefore also known as jointless bridges. IABs have many advantages, such as structural integrity, efficiency, and stability. More importantly, IABs have proven to be have both low maintenance and construction costs. However, due to the restraints at both ends of the girder due to the absence of a gap (joint), special design considerations are required. For example, while replacing the deck slabs to extend the service life of the IAB, the buckling strength of the steel girder without a deck slab could be much smaller than the case with deck slab in place. With no deck slab, the addition of thermal expansion in the steel girders generates passive earth pressure from the abutment and if the applied axial force is greater than the buckling strength of the steel girders, buckling failure can occur. In this study, numerical simulations were performed to estimate the buckling strength of typical steel girders in IABs. The effects of girder length, the width of flange and thickness of flange, imperfection due to fabrication and construction errors on the buckling strengths of multiple and single girders in IABs are studied. The effect of girder spacing, span length ratio (for a three span girder) and self-weight effects on the buckling strength are also studied. For estimation of the reaction force of the abutment generated by the passive earth pressure of the soil, BA 42/96 (2003), PennDOT DM4 (2015) and the LTI proposed equations (2009) were used and the results obtained are compared with the buckling strength of the steel girders. Using the selected design equations and the results obtained from the numerical analysis, equations for preventing the buckling failure of steel girders during deck replacement for maintenance are presented.

트러스근을 사용한 슈퍼데크 플레이트의 구조성능평가 (Structural Performance of Super-Deck Plate Slab System with Truss Type Bar)

  • 김성수;김상식;이우진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.193-199
    • /
    • 2003
  • This paper presents the results of an experimental research project on 7 Super Deck Plates with continuous or simple beam types. The test parameters included the distance of truss, depth of deck plate and the type of beam. The test results are as follows ; When thickness of deck plate was increased, maximum strength was improved When the distance of truss bar was reduced from 20cm to 15cm, the mean value of maximum load was increased to 1.21 times. Continuous beam shown superior to simple beam, such as 5.03 times high strength, low deflection at yield point.

매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보- (Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.235-245
    • /
    • 2004
  • 현재 합성 구조가 사용성 측면에서 경제적이고 작업성이 좋으며, 시공상의 편의성 등의 장점이 있다는 것은 일반화된 사실이지만, 자체의 춤이 깊기 때문에 철골조 건물에 적용하기에 여러 가지 비효율적 측면이 있다. 따라서 본 연구에서는 합성보의 전체 춤을 절감할 수 있도록 철골보의 춤내에 콘크리트를 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 이른바 "슬림플로어" 공법에 대한 연구를 수행하였다. 본 연구는 콘크리트에 매입된 비대칭 철골보를 가지는 부분 합성 슬림플로어 시스템의 휨거동에 관한 것이다. 총 8개의 실대형 실험체를 철골보 춤, 전단연결 유무, 슬래브 유효폭, 및 콘크리트 토핑두께 별로 제작하여 실험을 수행하였다. 실험결과, 별도의 전단연결재를 설치하지 않은 실험체는 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 완전합성보에 비해서 $0.53{\sim}0.95$의 전단합성비를 나타내었다.

당산철교의 설계 (Design of Dang-San Steel Railway Bridge)

  • 유동호;김선일
    • 전산구조공학
    • /
    • 제12권4호
    • /
    • pp.69-69
    • /
    • 1999
  • Design of Dangsan Steel Railway Bridge(a part of Seoul Subway Line NO. 2), which is supposed to be replaced after its 15years survice, was done, and the reconstruction has begun in Dec. 1997. The design include new superstruc-ture and bridge piers, retrofitting of the foun-dation, rail system, electric and signal, etc. In this paper, design of the structure is mainly summarized. The main span superstructure, across Han river, is composite section which is com-posed of steel box and reinforced concrete deck slab with 9 span continuous. The superstructure for the approaches is bottom througth type 2-cell steel box girder with steel floor system and concrete deck slab with 3 or 4 span continuous. The bridge piers was planned to be reconstructed based upon the result from the various investi-gations, while the foundation(cassion and pile foundation) was planned to be retrofitted. For superstructure erection, the method of combination of barge bent and heavy lifting and the launching truss method was investigated for the main span and approach spans, respectively.

  • PDF

Design thermal loading for composite bridges in tropical region

  • Au, F.T.K.;Cheung, S.K.;Tham, L.G.
    • Steel and Composite Structures
    • /
    • 제2권6호
    • /
    • pp.441-460
    • /
    • 2002
  • In the design of bridges, it is important to consider the thermal stresses induced by the non-linear temperature distribution as well as the variation of effective temperature in the bridge deck. To cope with this, design temperature profiles are provided by design codes, which are normally based on extensive research work. This paper presents the results of a comprehensive investigation on the thermal behaviour of bridges in Hong Kong with special emphasis on composite bridges. The temperature distribution in bridges depends primarily on the solar radiation, ambient air temperature and wind speed in the vicinity. Apart from data of the meteorological factors, good estimates of the thermal properties of material and the film coefficients are necessary for the prediction of temperature distribution. The design temperature profiles for various types of composite bridge deck with bituminous surfacing and concrete slab of different thicknesses are proposed. The factors affecting the design effective temperature are also reviewed and suitable values for Hong Kong are proposed. Results are compared with recommendations of the current local code. The method facilitates the development of site-specific temperature profiles for code documents, and it can also be applied to create zoning maps for temperature loading for large countries where there are great climatic differences.

강합성 2거더교 PSC 바닥판의 정적 거동 (Static Behavior of the Prestressed Concrete Deck Slab for Steel-Concrete Composite Two-Girder Bridges)

  • 김영진;주봉철;이정우;김병석;박성용
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.503-512
    • /
    • 2002
  • 본 연구는 PSC 바닥판의 설계 및 시공기술의 기초자료를 제공하고, 안전성을 평가하기 위해, 시험체를 제작하고, 정적 재하실험을 통해 거동특성과 파괴양상을 분석하였다. 대상교량은 40m 단경간 강합성 2거더교이며, 총폭원은 12m이고 거더간격은 6m이다. 본 연구에서는 교량의 주형부분을 제외한 바닥판 부분만을 대상으로 하였으며, 교축직각방향 중앙5m, 교축방향 중앙3 m를 절단한 것과 같은 실물부분모델을 제작하였다. 바닥판 두께를 변수로 하고, 교축방향의 연속성을 모사하는 강성보강재의 유ㆍ무를 구분하였다. 실험결과, 본 연구에서 검토한 바닥판들은 소정의 극한 휨강도를 만족시키고 있으며, 교축방향의 연속성모사를 위한 강성보강재의 유무에 따라 파괴양상이 다르게 나타났다.

천공된 각형강관을 이용한 슬림플로어 합성보의 내력실험 (Strength Measurements of Slim Floor Composite Beams used Perforated Square Shape Steel Pipe)

  • 김동연;임홍철;박성운;김도균;류승일;박대원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.189-190
    • /
    • 2015
  • Slim Floor construction method has to increase the available surface area thereby reducing the depth beams and slab. In addition, In this study compostie beam assembly of plates, square-shape steel pipe and deck plate. So workabiltiy is superior to the upper concrete possible without formwork. In the present study is strength test in progress in development slim floor composite beam used plate and perforated square shape steel pipe and obtained anlysis and conclustion of the experimental results.

  • PDF

Mechanical behavior of steel-concrete composite decks with perfobond shear connectors

  • Allahyari, Hamed;Dehestani, Mehdi;Beygi, Morteza H.A.;Neya, Bahram Navayi;Rahmani, Ebrahim
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.339-358
    • /
    • 2014
  • Exodermic deck systems are new composite steel grid deck systems which have been used in various projects during the past decade. One of the eminent features of this system is considerable reduction in the structure weight compared to the ordinary reinforced concrete decks and also reduction in construction time by using precast Exodermic decks. In this study, dynamic properties of the Exodermic deck bridges with alternative perfobond shear connectors are investigated experimentally. In order to evaluate the dynamic properties of the decks, peak picking and Nyquist circle fit methods are employed. Frequencies obtained experimentally are in good agreement with the results of the finite-element solution, and the experimental results show that the first mode is the most effective mode among the obtained modes. The first four modes are the rigid translational motion modes, and the next two modes seem to be rigid rotational motion modes around a horizontal axis. From the 7th mode onwards, modes are flexible. The range of damping ratios is about 0.5%. Furthermore, the static behavior of the Exodermic decks under a static load applied at the center of the decks was investigated. Failure of the decks under positive bending was punching-shear. The bending strength of the decks under negative bending was about 50 percent of their strength under positive bending. In addition, the weight of an Exodermic deck is about 40% of that of an equivalent reinforced concrete slab.