• Title/Summary/Keyword: Composite Sensor

Search Result 535, Processing Time 0.024 seconds

A Study on a Standard Strategy of EMU Control and Monitoring System for Improved Maintenance Efficiency (유지보수 효율향상을 위한 전동차 제어 및 감시시스템 표준화 방안 연구)

  • Lee, Woo-Dong;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.4
    • /
    • pp.241-245
    • /
    • 2013
  • In the case of the existing train control system, the driver monitors the condition of the vehicle through a composite controller device that displays various information on a screen in the vehicle. However, when problems arise such as car trouble, it is difficult for the drivers to take action immediately. In addition, maintenance personnel have to manually save data one by one after storing the vehicle to analyze control information of the main devices such as the brake controller and auxiliary power. To improve these points, a system that sends and receives all information in real time should be established by installing a sensor communication network and a surveillance system. This study attempts to improve the safety and maintenance of rail vehicles by suggesting a standardized method for train control and surveillance system.

Spatial Analysis by Matching Methods using Elevation data of Aerophoto and LIDAR (항공사진과 LIDAR 표고 데이터의 매칭 기법에 의한 공간정보 분석 연구)

  • Yeon, sang-ho;Lee, Young-wook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.449-452
    • /
    • 2008
  • The building heights of big cities which charged with most space are 3-D information as relative vertical distance from ground control points, but they didn't know the heights using contour with maps as lose of skyline or building heights for downtown, practically continuously developed of many technology methods for implementation of 3-D spatial earth. So, For the view as stereos of variety earth form generated 3-D spatial and made terrain perspective map, 3-D simulated of regional and urban space as aviation images. In this papers, it composited geospatial informations and images by DEM generation, and developed and presented for techniques overlay of CAD data and photos captured at our surroundings uses. Particularly, The airborne LiDAR surveying which are very interesting trend have laser scanning sensor and determine the ground heights through detecting angle and range to the grounds, and then designated 3-D spatial composite and simulation from urban areas. Therefore in this papers are suggested ease selections on the users situation by compare as various simulations that its generation of 3-D spatial image by collective for downtown space and urban sub, and the implementation methods for more accurate, more select for the best images.

  • PDF

Electrode Fabrication of MWCNT-PDMS Strain Sensors by Wet-etching (습식 식각을 이용한 MWCNT-PMDS 변형율 센서 전극 생성에 관한 연구)

  • Jung, La-Hee;Hwang, Hui-Yun
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.387-393
    • /
    • 2021
  • This paper investigated the electrical properties of multiwall carbon nanotube reinforced polydimethylsiloxane (CNT-PDMS) strain sensors with copper electrodes on the wet-etched surface. MWCNT-PDMS strain sensors were fabricated according to the wt% of MWCNT. Surfaces on the electrode area were wet-etched with various etching duration and silver epoxy adhesives were spread on the wet-etched surface. Finally, we attached the copper electrodes to the MWCNT-PMDS strain sensors. We checked the electric conductivities by the two-probe method and sensing characteristics under the cyclic loading. We observed the electric conductivity of MWCNT-PDMS strain sensors increased sharply and the scattering of the measured data decreased when the surface of the electrode area was wet-etched. Initial resistances of MWCNT-PDMS strain sensors were inversely proportion to wt% of MWCNT and the etching duration. However, the resistance changing rates under 30% strain increased as wt% of MWCNT and the etching duration increased. Decreasing rate of the electric resistance change after 100 repetitions was smaller when wt% of MWCNT was larger and the etching duration was short. This was due to the low initial resistance of the MWCNT-PMDS strain sensors by the wet-etching.

Stretchable Strain Sensors Using 3D Printed Polymer Structures Coated with Graphene/Carbon Nanofiber Hybrids (그래핀/탄소나노섬유 코팅된 3D 프린팅 고분자 구조를 이용한 신축성 스트레인 센서)

  • Na, Seung Chan;Lee, Hyeon-Jong;Lim, TaeGyeong;Yun, Jeongmin;Suk, Ji Won
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.283-287
    • /
    • 2022
  • Stretchable strain sensors have been developed for potential future applications including wearable devices and health monitoring. For practical implementation of stretchable strain sensors, their stability and repeatability are one of the important aspects to be considered. In this work, we utilized 3D printed polymer structures having kirigami patterns to improve the stretchability and reduce the hysteresis. The polymer structures were coated with graphene/carbon nanofiber hybrids to make a robust electrical network. The stretchable strain sensors showed a high gauge of 36 at a strain of 32%. Because of the kirigami structures and the robust graphene/carbon nanofiber coating, the sensors also exhibited stable resistance responses at various strains ranging from 1% to 30%.

Relationship Between Lower-limb Strength and Y-balance Test in Elderly Women

  • Eun-hye Kim;Sung-hoon Jung;Hwa-ik Yoo;Yun-jeong Baek;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.30 no.3
    • /
    • pp.194-201
    • /
    • 2023
  • Background: Falls are a common and serious problem in the elderly population. Muscle strength and balance are important factors in the prevention of falls. The Y-balance test (YBT) is used to assess dynamic postural control and shows excellent test-retest reliability. However, no studies have examined the relationship between lower-limb strength and YBT scores in elderly women. Objects: This study aimed to examine the relationship between lower-limb strength and YBT scores in elderly women. Methods: Thirty community-dwelling elderly women participated in the study. Lower-limb strength including hip flexor, hip extensor, hip abductor (HAB), hip adductor (HAD), knee flexor, knee extensor, ankle dorsiflexor, and ankle plantar flexor (PF) muscles was examined using a smart KEMA strength sensor (KOREATECH Inc.), and the YBT was used to assess dynamic balance. Relationship between lower-limb strength and YBT was demonstrated using a Pearson's correlation coefficient. Results: HAB strength (r = 0.388, p < 0.05), HAD strength (r = 0.362, p < 0.05), and ankle PF strength (r = 0.391, p < 0.05) positively correlated with the YBT-anterior direction distance. Ankle PF strength was positively correlated with the YBT-posteromedial direction distance (r = 0.396, p < 0.05) and composite score (r = 0.376, p < 0.05). Conclusion: The results of this study suggest that HAB, HAD, and ankle PF strengths should be considered for dynamic postural control in elderly women.

Measurements of the Temperature Coefficient of Resistance of CVD-Grown Graphene Coated with PEI (PEI가 코팅된 CVD 그래핀의 저항 온도 계수 측정)

  • Soomook Lim;Ji Won Suk
    • Composites Research
    • /
    • v.36 no.5
    • /
    • pp.342-348
    • /
    • 2023
  • There has been increasing demand for real-time monitoring of body and ambient temperatures using wearable devices. Graphene-based thermistors have been developed for high-performance flexible temperature sensors. In this study, the temperature coefficient of resistance (TCR) of monolayer graphene was controlled by coating polyethylenimine (PEI) on graphene surfaces to enhance its temperature-sensing performances. Monolayer graphene grown by chemical vapor deposition (CVD) was wet-transferred onto a target substrate. To facilitate the interfacial doping by PEI, the hydrophobic graphene surface was altered to be hydrophilic by oxygen plasma treatments while minimizing defect generation. The effect of PEI doping on graphene was confirmed using a back-gated field-effect transistor (FET). The CVD-grown monolayer graphene coated with PEI exhibited an improved TCR of -0.49(±0.03) %/K in a temperature range of 30~50℃.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Effect of Surfactants on ZnO Synthesis by Hydrothermal Method and Photocatalytic Properties (계면활성제 첨가에 의한 산화아연의 수열합성과 광촉매 특성)

  • Hyeon, Hye-Hyeon;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Zinc oxide is, one of metal oxide semiconductor, harmless to human and environment-friendly. It has excellent chemical and thermal stability properties. Wurtzite-zinc oxide is a large band gap energy of 3.37 eV and high exciton binding energy of 60 meV. It can be applied to various fields, such as solar cells, degradation of the dye waste, the gas sensor. The photocatalytic activity of zinc oxide is varied according to the particle shape and change of crystallinity. Therefore, It is very important to specify the additives and the experimental variables. In this study, the zinc oxide were synthesized by using a microwave assisted hydrothermal synthesis. The precursor was used as the zinc nitrate, the pH value was controlled as 11 by NaOH. Surfactants are the ethanolamine, cetyltrimethylammonium bromide, sodium dodecyl sulfate, sorbitan monooleate was added by changing the concentration. The composite particles had the shape of a star-like, curcular cone, seed shape, flake-sphere. Physical and chemical properties of the obtained zinc oxide was characterized using x-ray diffractometer, field emission scanning electron microscopy, thermogravimetric analysis and optical properties was characterized using UV-visible spectroscopy, photoluminescence and raman spectroscopy.

Improvement of Non-linear Estimation Equation of Rainfall Intensity over the Korean Peninsula by using the Brightness Temperature of Satellite and Radar Reflectivity Data (기상위성 휘도온도와 기상레이더 반사도 자료를 이용한 한반도 영역의 강우강도 추정 비선형 관계식 개선)

  • Choi, Haklim;Seo, Jong-Jin;Bae, Juyeon;Kim, Sujin;Lee, Kwang-Mog
    • Journal of the Korean earth science society
    • /
    • v.39 no.2
    • /
    • pp.131-138
    • /
    • 2018
  • The purpose of this study is to improve the quantitative precipitation estimation method based on satellite brightness temperature. The non-linear equation for rainfall estimation is improved by analysing precipitation cases around the Korean peninsula in summer. Radar reflectivity is adopted the CAPPI 1.5 and CMAX composite fields that provided by the Korea Meteorological Agency (KMA). In addition, the satellite data are used infrared, water vapor and visible channel measured from meteorological imager sensor mounted on the Chollian satellite. The improved algorithm is compared with the results of the A-E method and CRR analytic function. POD, FAR and CSI are 0.67, 0.76 and 0.21, respectively. The MAE and RMSE are 2.49 and 6.18 mm/h. As the quantitative error was reduced in comparison to A-E and qualitative accuracy increased in compare with CRR, the disadvantage of both algorithms are complemented. The method of estimating precipitation through a relational expression can be used for short-term forecasting because of allowing precipitation estimation in a short time without going through complicated algorithms.

Development of ionic liquid based solid state electrolyte and nanocarbon composite for all solid-state energy storage device (전고체형 에너지 저장 매체 제조를 위한 이온성 액체 기반의 고체 전해질과 탄소나노복합체 기반의 전극소재 개발)

  • Kim, Yong Ryeol;Kang, Hye Ju;Jeong, Hyeon Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1253-1258
    • /
    • 2019
  • The solid-state electrolyte based on polymer is applicable to various electrochemical devices including supercapacitor, battery, sensor, actuator and has great attention to develop its ionic conductivity from conventional polymer electrolyte by uisng wide range of ionic liquids. The research about ion gel as a solid state electrolyte with the ionic liquid has focused on the wearable and flexible electronic device to use as the high electrical and electrochemical performances, mechanical strength of polymer. In this work, we have investigated and developed solid-state electrolyte based on the ionic liquid and polymer with enhanced ionic conductivity and stability.