• Title/Summary/Keyword: Composite Piezoelectric Transducer

Search Result 39, Processing Time 0.027 seconds

Study on the Preparation of the Piezoelectric Composite Materials in PZT Ceramics-Polymers by Extrusion Method and its Properties (압출가공방법에 의한 PZT세라믹스-고분자 압전복합재료의 제조 및 특성 연구)

  • 이덕출;김진수
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.1
    • /
    • pp.74-78
    • /
    • 1990
  • In this study, to develope the ultrasonic transducer element, the extrusion method which is the processing technique of the piezoelectric composite materials is introduced, the connectivity of the piezoelectric composite materials is the 1-3 type, and we study the properties of the materials. The electromechanical coupling factor(kt) of the materials is above 0.6, the resonance property(fr) is the thickness mode in the frequency range of 0.5 to 2 [MHz] and the acoustic impedance(Zac) is about 5 to 7 [Maryl]. From these results, it is known that the piezoelectric composite materials manufactured byt he extrusion method will be able to develope the ultrasonic transducer elements.

  • PDF

Characteristics of Magnetoelectric Composite with Rosen Type Piezoelectric Transducer Structure (Rosen형 압전 변압기 구조를 적용한 자기-전기 복합체의 특성)

  • Park, Sung Hoon;Yoon, Woon-Ha;Patil, Deepak Rajaram;Ryu, Jungho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.480-486
    • /
    • 2021
  • Magnetoelectric (ME) composite is composed of a piezoelectric material and a magnetostrictive material. Among various ME structures, 2-2 type layered ME composites are anticipated to be used as high-sensitivity magnetic field sensors and energy harvesting devices especially operating at its resonance modes. Rosen type piezoelectric transducer using piezoelectric material is known to amplify a small electrical input voltage to a large electrical output voltage. The output voltage of these Rosen type piezoelectric transducers can be further enhanced by modifying them into ME composite structures. Herein, we fabricated Rosen type ME composites by sandwiching Rosen type PMN-PZT single crystal between two Ni layers and studied their ME coupling. However, the voltage step-up ratio at the resonance frequency was found to be smaller than the value calculated with αME value. The ATILA FEA (Finite Elements Analysis) simulation results showed that the position of the nodal point was changed with the presence of a magnetostrictive layer. Thus, while designing a Rosen type ME composite with high performance in a resonant driving situation, it is necessary to optimize the position of the nodal point by optimizing the thickness or length of the magnetostrictive layer.

Pulse response characteristics and preparation of piezoelectic composite materials with 1-3 connectivity (1-3형 압전복합재료의 제조 및 펄스응답특성)

  • 김진수;김용혁;김호기;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1989.06a
    • /
    • pp.77-80
    • /
    • 1989
  • The aim of the study is to develope the processing technique of PZT-Polymer piezoelectric composite materials for ultrasonic transducer application such as biomedical probe and hydrophone. Piezoelectric composite of PZT and polymer with 1-3 connectivity patterns have been fabricated by dicing-filling method and extrusion forming method. In this study processing forming method. In the study processing steps by extrusion forming method in the preperation of PZT/polymer piezoelectric composites are described. The PZT powder used in the study is commercial powder which is prepared by mixing PbO, TiO$_2$ and ZrO$_2$. The binder, water and plasticizer are mixed with the PZT powder to form a slip. It is necessary to adjust the viescosity of slip according on the PZT rod diameters to be extruded. The electromechanical properties of the piezoelectric composites are characterized in terms of the thickness resonance mode. The pulse response characteristics by the ultrasonic transducer analyzer and osciloscope are evaluated.

  • PDF

Characteristics of The 1-3 Piezoelectric Composite Transducer Manufactured by Dicing-Filling Method (Dicing-Filling 방법으로 제작된 1-3 압전복합변환자의 특성)

  • Kim, W.S.;Yun, U.H.;Ok, C.I.;Kim, S.B.;Lee, J.K.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.33-37
    • /
    • 2000
  • The 1-3 piezoelectric composite transducer with 75 volume percents PZT was fabricated by the dicing-filling method. The resonance modes of the 1-3 transducer have been studied with electric impedance measurement as a function of frequency. The fundamental frequencies of the planar and thickness mode were observed at 0.95MHz and 1.63MHz respectively, but the lateral mode was not observed. In the thickness mode, the electromechanical coupling coefficient of the 1-3 piezoelectric composite transducer, 0.54, was very closed to that of the single phase PZT(0.52). The pulse-echo response by exciting the 1-3 transducer with an electric pulse was observed from the water/reflector interface, and analyzed bandwidth by the spectrum of the impulse response. The quality factor Q for the 1-3 transducer was observed as 1.5 smaller than that of the single phase(80) and then the 1-3 transducer may be used to the broad band type transducer applications.

  • PDF

A characteristic study on the transmisson-reception and fabrication of the ultrasonic transducer using composite with 1-3 connectivity (1-3형 복합재료를 이용한 초음파 Transducer의 제작과 송수신 특성연구)

  • Kim, Chan-Young;Lee, Duck-Chool;Kim, Ho-Gi;Kim, Yong-Huck
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.72-74
    • /
    • 1989
  • A composite with 1-3 connectivity was fabricated by filling spurrs epoxy in arried PZT bars. The composite bad lower density(2220 Kg/$m^3$), lower dielectric constant, lower piezoelectric coefficient d33(260*$10^{12}$ C/N), and higher voltage coefficient(110.1*$10^{-3}$ Vm/N) than that of solid PZT. The probe was fabricated by using composite transducer that was made above. The underwater testing of the composite transducer was performed with water backing.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

A High-sensitivity Passive Magnetic Transducer Based on PZT Plates and a Fe-Ni Fork Substrate

  • Li, Ping;Wen, Yumei;Jia, Chaobo;Li, Xinshen
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.271-275
    • /
    • 2011
  • This paper proposes a magnetoelectric (ME) composite transducer structure consisting of a magnetostrictive H-type Fe-Ni fork substrate and piezoelectric PZT plates. The fork composite structure has a higher ME voltage coefficient compared to other ME composite structures due to the higher quality (Q) factor. The ME sensitivity of the fork structure reaches 12 V/Oe (i.e., 150 V/cm Oe). The fork composite with two PZT plates electrically connected in series exhibits over 5 times higher ME voltage coefficient than the output of the rectangle structure in the same size. The experiment shows the composite of a Fe-Ni fork substrate and PZT plates has a significantly enhanced ME voltage coefficient and a higher ME sensitivity relative to the prior sandwiched composite laminates. By the use of a lock-in amplifier with 10 nV resolution, this transducer can detect a weak magnetic field of less than $10^{-12}$ T. This transducer can also be designed for a magnetoelectric energy harvester due to its passive high-efficiency ME energy conversion.

Experimental Investigation of Characteristics Change by Kerf-Fill Material between Arrayed Elements of a Piezoelectric Transducer (압전 배열 트랜스듀서의 진동 요소간 kerf 충진 매질에 따른 특성변화의 실험적 고찰)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.215-220
    • /
    • 2008
  • The kerfs between arrayed piezoelectric elements in a medical ultrasonic transducer or a piezoelectric composite transducer are generally filled by polymeric materials. The boundary condition of the elements for lateral mode vibration is changed according to the kerf-filling materials, so that the resonance frequency for longitudinal mode of the transducer is also varied. In this study, to investigate the resonance frequency variation for an arrayed transducer experimentally, the piezoelectric vibration elements of $14mm{\times}0.22mm{\times}0.44mm$ were fabricated and those were linearly arrayed. And, the resonance frequencies were measured for three cases of kerf-filling condition, non-filling and two different kinds of epoxy filling. Conclusively, it is confirmed that the resonant frequency variation shows the similar tendency with the theoretical one for the longitudinal mode.

PVDF interdigitated transducer for generating and detecting Lamb waves in plates

  • Gu, Hua;Lloyd, George M.;Wang, Ming L.
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.291-304
    • /
    • 2008
  • Piezoelectric materials have been widely used in ultrasonic nondestructive testing (NDT). PZT ceramics can be used to receive and generate surface acoustic waves. It is a common application to attach PZT transducers to the surface of structures for detecting cracks in nondestructive testing. However, not until recently have piezoelectric polymers attracted more and more attention to be the material for interdigitated (IDT) surface and guided-wave transducers. In this paper, an interdigitated gold-on-polyvinylidene fluoride (PVDF) transducer for actuating and sensing Lamb waves has been introduced. A specific etching technology is employed for making the surface electrodes into a certain finger pattern, the spacings of which yield different single mode responses of Lamb waves. Experiments have been performed on steel and carbon fiber composite plates. Results from PVDF IDT sensors have been compared with those from PZT transducers for verification.

Nondestructive Evaluation of Damage Modes in a Bending Piezoelectric Composite Actuator Based on Waveform and Frequency Analyses (파형 및 주파수해석에 근거한 굽힘 압전 복합재료 작동기 손상모드의 비파괴적 평가)

  • Woo, Sung-Choong;Goo, Nam-Seo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.8
    • /
    • pp.870-879
    • /
    • 2007
  • In this study, various damage modes in bending unimorph piezoelectric composite actuators with a thin sandwiched PZT plate during bending fracture tests have been evaluated by monitoring acoustic emission (AE) signals in terms of waveform and peak frequency as well as AE parameters. Three kinds of actuator specimens consisting of woven fabric fiber skin layers and a PZT ceramic core layer are loaded with a roller and an AE activity from the specimen is monitored during the entire loading using an AE transducer mounted on the specimen. AE characteristics from a monolithic PZT ceramic with a thickness of $250{\mu}m$ are examined first in order to distinguish different AE signals from various possible damage modes in piezoelectric composite actuators. Post-failure observations and stress analyses in the respective layers of the specimens are conducted to identify particular features in the acoustic emission signal that correspond to specific types of damage modes. As a result, the signal classification based on waveform and peak frequency analyses successfully describes the failure process of the bending piezoelectric composite actuator exhibiting diverse failure mechanisms. Furthermore, it is elucidated that when the PZT ceramic embedded actuators are loaded mechanical bending loads, the failure process of actuator specimens with different lay-up configurations is almost same irrespective of their lay-up configurations.