• Title/Summary/Keyword: Composite Degree

Search Result 755, Processing Time 0.032 seconds

Renovation of steel beams using by imperfect functionally graded materials plate

  • Daouadji, Tahar Hassaine;Abderezak, Rabahi;Rabia, Benferhat;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.41 no.6
    • /
    • pp.851-860
    • /
    • 2021
  • In this paper, a new approach of interface stress analysis in steel beam strengthened by porous FGM (Functionally Graded Materials) is presented to calculate the shear stress in the hybrid steel beam and loaded by a uniformly distributed load. The results show that there exists a high concentration of shear stress at the ends of the imperfect FGM, which might result in premature failure of the strengthening scheme at these locations. A parametric study has been conducted to investigate the sensitivity of interface behavior to parameters such as the rigidity of FGM plate (degree of homogeneity), the porosity index of FGM and the thickness of adhesive all were found to have a marked effect on the magnitude of maximum shear stress in the FGM member. we can conclude that the new approach is general in nature and may be applicable to all kinds of materials.

A New Study of Sensing and Optimum Preparation Conditions of Graphite/Different Paper Sensors for Composite Materials (복합재료용 흑연/종이 센서의 최적제조조건 및 감지능 평가 연구)

  • Park, Ha-Seung;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Joung-Man
    • Composites Research
    • /
    • v.31 no.2
    • /
    • pp.51-56
    • /
    • 2018
  • A new study was carried out to utilize a pencil drawing paper sensor (PDPS), which drew a line using a pencil on the paper, as a sensor. The sensing effect on 3 different papers based on the properties of PDPS was compared. The specimens were prepared by drawing 4B pencils on plain (A4), Hwasun, and Han papers. The silver paste was used to give good electrical contacts of the copper wires and the pencil drawn line. The chemical structures of 3 papers for PDPS by FT-IR spectrum analysis were similar and the comparative compact states of each paper were observed by optical microscope. From statistical evaluation of tensile strength using 3 papers, plain paper was chosen to be best for the PDPD. The optimum drawing number of PDPD was determined by changing the thickness of the paper with the drawing number. Electrical resistance (ER) with graphite on 3 different papers were compared. The changes in compression was observed through cyclic compressive test of composite materials, it was possible to predict the degree of strain sensing under compressive test. It leads to expectation of properties.

FINITE ELEMENT ANALYSIS OF THE INFLUENCE OF ESTHETIC POSTS ON INCISORS (심미 포스트가 전치에 미치는 응력과 변위에 관한 삼차원 유한요소법적 분석)

  • Kwon Tae-Hoon;Hwang Jung-Won;Kim Sung-Hun;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.582-595
    • /
    • 2003
  • Statement of problem : Most posts are metallic, but in response to the need for a post that possesses optical properties compatible with an all-ceramic crown. an esthetic post has been developed. Although there have been many studies about the esthetic post materials, 3-dimensional finite element studies about the stress distribution of them are in rare. Purpose : The purpose of this study is to investigate comparatively the distribution of stresses of the restored, endodontically treated maxillary incisors with the esthetic post materials and the displacement on the cement layer on simulated occlusal loading by using a 3-dimensional finite element analysis model. Material and method : Four 3-dimensional finite element models were constructed in a view of a maxillary central incisor, a post, a core, and the supporting tissues to investigate the stresses in various esthetic posts and cores and the displacement on the cement layer (Model 1 ; Cast gold post and core, Model 2 ; Glass fiber post with composite core, Model 3 ; Zirconia post with composite core. Model 4 ; Zirconia post with ceramic core). Force of 300N was applied to the incisal edge and the cingulum (centric stop point) with the angle of 135-degree to the long axis of the tooth. Results : 1. The stresses and displacement on the incisal edge were higher than on the cingulum 2. The stresses in dentin were the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. 3. The stresses in post and core were the highest in Model 4 (Zirconia post with ceramic core), and the second was Model 1, the third Model 3, and the lowest Model 2. 4. The displacement on the cement layer was the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. Conclusion : When a functional maximum bite force was applied, the distribution of stresses or the esthetic post and core materials and the displacement on the cement layer were a little different. It seems that restoring extensively damaged incisors with esthetic post and core materials would be decided according to the remaining tooth structure.

Cyclic Seismic Testing of Concrete-filled U-shaped Steel Beam-to-Steel Column Connections (콘크리트채움 U형 강재보-강재기둥 합성 내진접합부에 대한 주기하중 실험)

  • Park, Hong-Gun;Lee, Cheol-Ho;Park, Chang-Hee;Hwang, Hyeon-Jong;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.337-347
    • /
    • 2011
  • In this study, seismic resistance of concrete encased U-shaped steel beam-to-steel H-shaped column connections was evaluated. Three specimens of the beam-to-column connection were tested under cyclic loading. The composite beam was integrated with concrete slab using studs. Re-bars for negative moment were placed in the slab. The primary test parameter was the details of the connections, which are strengthening and weakening strategies for the beam end and the degree of composite action. The depth of the composite beams was 600mm including the slab thickness. The steel beam and the re-bars in the slab were weld-connected to the steel column. For the strengthening strategy, cover plates were weld-connected to the bottom and top flanges of the steel beam. For the weakening strategy, a void using styrofoam box was located inside the core concrete at the potential plastic hinge zone. The test results showed that the fully composite specimens exhibited good strength, deformation, and energy dissipation capacities. The deformation capacity of the beam exceeded 4% rotation angle, which is the requirement for the Special Moment Frame.

Quantitative Damage Evaluation of Fiber-Reinforced Cement Composite Using Acoustic Emission Technique (음향방출 기법을 이용한 섬유보강 시멘트 복합체의 정량적 손상평가)

  • Lee, Young-Oh;Yun, Yeo-Jin;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.457-464
    • /
    • 2009
  • Fiber is an important ingredient in fiber-reinforced cement composite (FRCC) which can control fracture of cement composite by bridging action. In compliance with the action of the fiber and the aggregate size, it also showed a different failure mechanism. For practical application, it is needed to investigate the fracture behavior of the FRCC and to understand the micro-mechanism of cement matrix with reinforcing fiber. In order to evaluate a characteristics of fracture process in the FRCC, acoustic emission (AE) technique was used for the analysis and evaluation of FRCC damage by acoustic emission under flexural and cyclic compressive loadings. The AE signals were monitored by AMSY4 AE instrument during the entire loading period. The specimens are reinforced with 0, 1.0, 1.5 and 2.0% (by volume) Polyvinyl alcohol (PVA) fiber. The test results showed that the damage progress of the FRCC was characteristic for the fiber replacement ratio. As a result of analyzing the felicity ratio (FR) values, it is shown that this values can be used for evaluating the degree of FRCC damage. On the whole the felicity ratio values of FRCC are shown between 0.4 and 1.1. And, the AE kaiser effect was shown in the all FRCC specimen. In addition, the damage behavior and the microscopic fracture process of the FRCC are evaluated using the AE parameters, such as calm ratio, b-value and felicity ratio. The purpose of this reserch was to advance the state of knowledge regarding the applicability of acoustic emission as an evaluation method for FRCC.

Preparation of Self-repairing Polymer-modified Waterproofing Asphalt-montmorillonite Composite: 1. Silylation Characteristics of Montmorillonite (K-10) Using 3-aminopropyltriethoxysilane and its Optimal Condition According to a Criterion by XRD Analysis (자가치유성을 갖는 고분자개질 방수아스팔트-몬모릴로나이트 composite 제조: 1. 3-aminopropyltriethoxysilane에 의한 몬모릴로나이트(K-10)의 실란화 특성 및 XRD 분석의 기준에 따른 최적화)

  • Lee, Eun Ju;Lee, Jong Hoon;Park, You Jin;Yoon, Yong Keun;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.401-408
    • /
    • 2017
  • In preparation of self-repairing polymer-modified waterproofing asphalt-montmorillonite (MMT) composite, silylation-modification characteristics of cation ($Na^+$) exchanged K-10 (Na-MMT-K) using 3-aminopropyltriethoxysilane (APS) were studied and the optimal conditions of its silylation-modification process were proposed by use of the results of XRD analysis on silylation-modified Na-MMT-K (S-Na-MMT-K) under various conditions. According to XRD results, it was confirmed that peaks of Na-MMT-K were simultaneously consistent with those of K-10 and natural or Ca-MMT modified Na-MMT. Similarly, S-Na-MMT-K was observed to have two basal spacings ($d_{001}$), among which the area-ratio of a secondary (001) peak ($2{\theta}=3.9{\sim}4.2^{\circ}$) to a primary (001) peak ($2{\theta}{\sim}8.838^{\circ}$) was suggested to be a criterion to represent a degree of APS silylation-modification. Then, the optimal conditions on APS-stirring period prior to APS-MMT reaction, APS-MMT reaction period, APS concentration and reaction temperature at the highest area-ratio were turned out to be 20 min, 2~3 hr, 7.5 w/v% and $50^{\circ}C$, respectively.

COMPARATIVE STUDY ON REMINERALIZING EFFECT OF COMPOMERS (컴포머의 재석회화 효과에 관한 비교 연구)

  • Chung, Hoi-Min;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.498-508
    • /
    • 2002
  • The purpose of this study was to compare the amount of fluoride release and remineralizing effect of compomer with those of glass ionomer cement and composite resin. Composite resin($Z-100^{(R)}$) was used for negative control group(Group I), glass ionomer(Fuji II $LC^{(R)}$) for positive control group(Group IV), compomer(Dyract $AP^{(R)}$ and $F-2000^{(R)}$) for experimental group(Group II and Group III). The results obtained can be summarized as follows : 1. Glass ionomer showed the higher amount of fluoride release than compomer groups. Composite resin showed no fluoride release during test period. 2. Significant evidence of remineralization could be noticed in samples of all groups. The highest degree of remineralization was observed in glass ionomer group followed by compomer group. The least evidence of remineralization was observed in composite resin group. 3. Microhardness values of carious site was lower than control site, but Microhardness values of caries site at form away from filling materials in group II, III, IV was significantly higher than the other area. Based on the above results, compomer could be considered as one of the very attractive restorative materials in the field of pediatric dentistry.

  • PDF

An Investigation on the Nonlinear Shear Behavior of FRP Composites Considering Temperature Variation and Fabricating Parameters (FRP 복합재료의 온도변화 및 제작인자별 비선형 전단거동 조사)

  • Jung, Woo-Young;Hwang, Jin-Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.833-841
    • /
    • 2013
  • In the case of composite material, a variety of characteristics were expressed depending on the materials that were composed of. In this study, the materials showing non-linear shear behavior were investigated among FRP composite. Each specimen was designed and analyzed according to ASTM D4255 method: regulations on the 2-rail. The dependent variables included in this experiment were a variety of fiber, fiber volume ratio, fiber array direction, temperature, material homogeneity. For determination of characteristics based on the fiber array, fiber array direction of 0, 30, 45, and 60 degrees were selected for test specimen. Temperature of 25, 40, 60, and $80^{\circ}C$ were considered for investigation of FRP materials'shear behavior based on the external temperature. Nonlinear shear behavior was observed throughout the FRP composite material in this study. Also, using vinyl ester resins, high fiber volume ratio, and fiber array direction of 45 degree appeared to show the most prominent nonlinear shear behavior. As for the findings related to the temperature change, non-linear behavior was decreased as the external temperature increased. For factory manufactured product, non-linear behavior was relatively at parity in comparison to the behavior found in the hand lay-up FRP composite specimen.

THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS (가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구)

  • Kim, Sang-Bae;Lee, Kwang-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.180-188
    • /
    • 2002
  • Newly developed curing units(plasma arc curing units) operate at relatively high intensity and are claimed to result in optimum properties of composite resin in a short curing time. The purpose of this study was to evaluate the microhardness and microleakage at the resin-tooth interface of two types of composite resins polymerized with visible light and plasma arc curing units. The results from the present study can be summarized as follows 1. Microhardness in each depth was shown to be higher in group AHL than AP3 & AP6. Group ZHL was lower than AP6 at surface(p<0.05) and had no statistically significant difference at 1mm and 2mm(p>0.05). In other depths, group ZHL was higher than ZP3 and ZP6(p<0.05). 2. The incremental reduction in microhardness with depth was shown to be in all group except in surface-1mm of group AHL and $1{\sim}2mm$ of group ZHL(p<0.05). 3. Degree of microleakage in all oops were shown to be higher in gingival margin than occlusal margin but no statistically significant difference(p>0.05). 4. Differences between curing methods in microleakage were shown to be no statistically significant difference(p>0.05). 5. Differences between composite resins in microleakage were shown to be no statistically significant differ once(p>0.05).

  • PDF

MICROLEAKAGE IN RESIN COMPOSITE POLYMERIZED WITH VARIOUS LIGHT CURING UNITS (수종의 광중합기에 의한 복합레진 중합시 미세누출에 관한 연구)

  • Park, Sung-Jin;Kim, Dae-Eup;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.604-610
    • /
    • 2005
  • This study was to evaluate the effects of several light curing units on the microleakage of composite resin restorations in primary teeth. The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Filpo) low heat plasma arc light(Aurys) and high intensity LED(Freelight 2). After preparing cavities on sound primary teeth, cavities were filled with composite resin(Z100) using the same resin bond agent(Scotchbond Multi-Purpose) and were cured with each curing light system. After storing each specimen in sterile water for 24 hours, thermal circulation was done 1,000 times followed by pigmentation using 2% methylene blue solution. Each specimen was sliced and the degree of pigmentation was graded. When microleakage is graded, the average of Aurys was 0.95 which was the lowest and Freelight 2(1.05), Filpo(1.25), Optilux 360(1.30) followed. But values were not shown statistically significant difference (P>0.05). The results suggest that the newly developed curing units which has advantage in children by decreasing discomfort and procedure time can increase the microleakage of the composite resin.

  • PDF