• Title/Summary/Keyword: Composite Capacity

Search Result 1,793, Processing Time 0.027 seconds

Experimental studies on composite beams with high-strength steel and concrete

  • Zhao, Huiling;Yuan, Yong
    • Steel and Composite Structures
    • /
    • v.10 no.5
    • /
    • pp.373-383
    • /
    • 2010
  • This paper presents the experimental studies of the flexural behavior of steel-concrete composite beams. Herein, steel-concrete composite beams were constructed with a welded steel I section beam and concrete slab with different material strength. Four simply supported composite beams subjected to two-point concentrated loads were tested and compared to investigate the effect of high strength engineering materials on the overall flexural response, including failure modes, load deflection behavior, strain response and interface slip. The experimental results show that the moment capacity of composite beams has been improved effectively when high-strength steel and concrete are used. Comparisons of the ultimate flexural strength of beams tested are then made with the calculated results according to the methods specified in guideline Eurocode 4. The ultimate flexural strength based on current codes may be slightly unconservative for predicating the moment capacity of composite beams with high-strength steel or concrete.

Theoretical study of UHPCC composite column behaviors under axial compression

  • Wu, Xiang-Guo;Zou, Ruofei;Zhao, Xinyu;Yu, Qun
    • Structural Engineering and Mechanics
    • /
    • v.55 no.5
    • /
    • pp.931-951
    • /
    • 2015
  • To improve the durability and service life of reinforced concrete column such as bridge piers, an advanced composite column made of Ultra High Performance Cementitious Composites (UHPCC) permanent form is proposed. Based on elasticity plasticity theory, axial compression behavior of the composite column was studied theoretically. The first circumferential cracking load and ultimate limit loading capacity are derived for the composite column. Short composite column compression tests and numerical simulations using FEM method were carried out to justify the theoretical formula. The effects of UHPCC tube thickness on the axial compression behavior were studied. Using the established theoretical model and numerical simulation, the large dimension composite columns are calculated and analyzed with different UHPCC tube thickness. These studies may provide a reference for advanced composite column design and application.

Electrochemical Properties of LiMnO2-organic Composite Cathodes with High Capacity for Lithium Ion Polymer Battery (리튬 이온 폴리머 전지용 고용량 LiMnO2-organic Composite 정극의 전기화학적 특성)

  • 김종욱;조영재;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.162-168
    • /
    • 2002
  • The purpose of this study is to research and develop LiMnO$_2$-organic and Li$_{0.3}$MnO$_{2}$-organic composite with high energy density for Lithium ion polymer battery. This paper describes cyclic voltammetry, impedance sepctroscopy, electrochemical properties of LiMnO$_2$-organic and Li$_{0.3}$MnO$_{2}$-organic composite with polymer electrolyte as a function of a mixed ratio. The first discharge capacity of LiMnO$_2$-PAn with 3 wt.% PAn was 83mHA/g, while that of Li$_{0.3}$MnO$_{2}$-PPy composite was 136 mAh/g. The Ah efficiency was above 98% after the 2nd cycle. The LiMnO$_2$-PAn with DMcT 2 wt.% and Li$_{0.3}$MnO$_{2}$-PPy composites cathode with 5wt. PPy in PVDF-PC-EC-LiClO$_4$ electrolyte showed good capaity with cycling. The discharge capacity of LiMnO$_2$-PAn with wt.% DMcT was 80 and 130 mAh/g at 1st and 12th cycle, respectively. The capacity of LiMnO$_2$-PAn composite with 2 wt.% DMcT was higher than that of LiMnO$_2$-PAn composite.mposite.

Cyclic tests and numerical study of composite steel plate deep beam

  • Hu, Yi;Jiang, Liqiang;Zheng, Hong
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.23-34
    • /
    • 2017
  • Composite steel plate deep beam (CDB) is proposed as a lateral resisting member, which is constructed by steel plate and reinforced concrete (RC) panel, and it is connected with building frame through high-strength bolts. To investigate the seismic performance of the CDB, tests of two 1/3 scaled specimens with different length-to-height ratio were carried out under cyclic loads. The failure modes, load-carrying capacity, hysteretic behavior, ductility and energy dissipation were obtained and analyzed. In addition, the nonlinear finite element (FE) models of the specimens were established and verified by the test results. Besides, parametric analyses were performed to study the effect of length-to-height ratio, height-to-thickness ratio, material type and arrangement of RC panel. The experimental and numerical results showed that: the CDBs lost their load-carrying capacity because of the large out-of plane deformation and yield of the tension field formed on the steel plate. By increasing the length-to-height ratio of steel plate, the load-carrying capacity, elastic stiffness, ductility and energy dissipation capacity of the specimens were significantly enhanced. The ultimate loading capacity increased with increasing the length-to-height ratio of steel plate and yield strength of steel plate; and such capacity increased with decreasing of height-to-thickness ratio of steel plate and gap. Finally, a unified formula is proposed to calculate their ultimate loading capacity, and fitting formula on such indexes are provided for designation of the CDB.

Nonlinear analysis of concrete-filled steel composite columns subjected to axial loading

  • Bahrami, Alireza;Badaruzzamana, Wan Hamidon Wan;Osmanb, Siti Aminah
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.383-398
    • /
    • 2011
  • This paper investigates the nonlinear analysis of concrete-filled steel composite columns subjected to axial loading to predict the ultimate load capacity and behaviour of the columns. Finite element software LUSAS is used to conduct the nonlinear analyses. The accuracy of the finite element modelling is verified by comparing the result with the corresponding experimental result reported by other researchers. Nonlinear analyses are done to study and develop different shapes and number of cold-formed steel sheeting stiffeners with various thicknesses of cold-formed steel sheets. Effects of the parameters on the ultimate axial load capacity and ductility of the concrete-filled steel composite columns are examined. Effects of variables such as concrete compressive strength $f_c$ and cold-formed steel sheet yield stress $f_{yp}$ on the ultimate axial load capacity of the columns are also investigated. The results are shown in the form of axial load-normalized axial shortening plots. It is concluded from the study that the ultimate axial load capacity and behaviour of the concrete-filled steel composite columns can be accurately predicted by the proposed finite element modelling. Results in this study demonstrate that the ultimate axial load capacity and ductility of the columns are affected with various thicknesses of steel sheets and different shapes and number of stiffeners. Also, compressive strength $f_c$ of the concrete and yield stress $f_{yp}$ of the cold-formed steel sheet influence the performance of the columns significantly.

Strengthening of steel-concrete composite beams with prestressed CFRP plates using an innovative anchorage system

  • Wan, Shi-cheng;Huang, Qiao;Guan, Jian
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.21-35
    • /
    • 2019
  • This study investigates the flexural behavior of steel-concrete composite beams strengthened with prestressed carbon fiber-reinforced polymer (CFRP) plates. An innovative mechanical anchorage system was developed. The components of the system can be easily assembled on site before applying a prestressing force, and removed from the structures after strengthening is completed. A total of seven steel-concrete composite specimens including four simply supported beams strengthened at the positive moment region and three continuous beams strengthened at the negative moment region were tested statically until failure. Experimental results showed that the use of prestressed CFRP plates enhanced the flexural capacity and reduced the mid-span deflection of the beams. Furthermore, by prestressing the CFRP laminates, the material was used more efficiently, and the crack resistance of the continuous composite specimens at the central support was significantly improved after strengthening. Overall, the anchorage system proved to be practical and feasible for the strengthening of steel-concrete composite beams. The theoretical analysis of ultimate bearing capacity is reported, and good agreement between analytical values and experimental results is achieved.

An Study on the flexural capacity of 'Hybrid Beam' (하이브리드 보의 휨성능에 관한 연구)

  • Hong, Sung-Gul;Yang, Dong-Hyun;Jung, Jong-Hyun;Lim, Byung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.301-304
    • /
    • 2006
  • This study was performed to suggest a theoretical method of flexural capacity of 'Hybrid Beam'. Since the center of 'Hybrid Beam' is composed of embedded composite beam section, a theoretical method of embedded composite beam could be applied to estimation of flexural capacity of 'Hybrid Beam'. In this study, a theoretical evaluation method for flexural capacity of embedded composite beam, which is suggested by KBC 2005, is chosen and its applicability is evaluates as comparing theoretical results with experimental results. In results, for estimation of theoretical ultimate strength, it is proper method that both effects due to concrete and rebar are considered and whole section is assumed to be plastic. and for estimation of theoretical strength at yielding stste, it is proper to apply allowable stress design.

  • PDF

A Novel Method to Fabricate Tough Cylindrical Ti2AlC/Graphite Layered Composite with Improved Deformation Capacity

  • Li, Aijun;Chen, Lin;Zhou, Yanchun
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.4
    • /
    • pp.369-374
    • /
    • 2012
  • Based on the structure feature of a tree, a cylindrical $Ti_2AlC$/graphite layered composite has been fabricated through heat treating a graphite column and six close-matched thin wall $Ti_2AlC$ cylinders bonded with the $Ti_2AlC$ powders at $1300^{\circ}C$ and low oxygen partial pressure. SEM examination reveals that the bond interlayers between cylinders or that between cylinder and column are not fully dense without any crack formation. During the compressive test, the strain of the $Ti_2AlC$/graphite layered composite is about twice higher than that of the monolithic $Ti_2AlC$ ceramic, and the compressive strength of the layered composite is 348 MPa. The layered composite show the noncatastrophic fracture behaviors due to the debonding and shelling off of the layers, which are different from the monolithic $Ti_2AlC$ ceramic. The mechanism of the improved deformation capacity and noncatastrophic failure modes are attributed to the presence of the central soft graphite column and cracks deflection by the bond interlayers.

Effect of fibers and welded-wire reinforcements on the diaphragm behavior of composite deck slabs

  • Altoubat, Salah;Ousmane, Hisseine;Barakat, Samer
    • Steel and Composite Structures
    • /
    • v.19 no.1
    • /
    • pp.153-171
    • /
    • 2015
  • Twelve large-scale composite deck slabs were instrumented and tested in a cantilever diaphragm configuration to assess the effect of fibers and welded wire mesh (WWM) on the in-plane shear capacity of composite deck slabs. The slabs were constructed with reentrant decking profile and reinforced with different types and dosages of secondary reinforcements: Conventional welded wire mesh (A142 and A98); synthetic macro-fibers (dosages of $3kg/m^3$ and $5.3kg/m^3$); and hooked-end steel fibers with a dosage of $15kg/m^3$. The deck orientation relative to the main beam (strong and weak) was also considered in this study. Fibers and WWM were found efficient in distributing the applied load to the whole matrix, inducing multiple cracking, thereby enhancing the strength and ductility of composite deck slabs. The test results indicate that fibers increased the slab's ultimate in-plane shear capacity by up to 29% and 50% in the strong and weak directions, respectively. WWM increased the ultimate in-plane shear capacity by up to 19% in the strong direction and 9% in the weak direction. The results suggest that discrete fibers can provide comparable diaphragm behavior as that with the conventional WWM.

Seismic Performance of Prefabricated Composite Column for Accelerated Bridge Construction (급속시공을 위한 조립식 합성교각의 내진성능 평가)

  • Lee, Jung-Woo;Chin, Won-Jong;Joh, Chang-Bin;Kwark, Jong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.425-430
    • /
    • 2010
  • This paper investigates the seismic behavior of a prefabricated composite column which is made by onsite connection of precast composite column segments to accelerate bridge construction. Quasi-static cyclic loading tests were performed on three prefabricated composite columns with different connection details to find their seismic capacity. Test results show that the onsite connections remains in elastic range and no slip is observed as designed in spite of plastic hinge formation at the column. The test results also indicate that the prefabricated composite column has better overall seismic capacity compared to a conventional reinforced concrete column with seismic details.