• 제목/요약/키워드: Composite Alumina

검색결과 262건 처리시간 0.022초

광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF

Al$_2$O$_3$/Al 복합체 제조시 용융 알루미늄의 치환반응에 미치는 금속 마그네슘의 영향 (Effects of Metal Mg on Replacement Reaction of Molten Al for Fabrication of $Al_2$O$_3$//Al Composites)

  • 정두화;배원태
    • 한국세라믹학회지
    • /
    • 제35권1호
    • /
    • pp.23-32
    • /
    • 1998
  • 전융실리카 분말로 소결하여 만든 sihca preform을 마그네슘이 함유된 용융 알루미늄에 침적시킨후 공기중에서 반응시켜 Al2O3/Al 복합체를 제조하였다. 복합체 제조시 반응온도의 변화에 대해 용융 알루미늄의 침투거동을 조사한 결과 3가지 영역, 즉 저온영역(75$0^{\circ}C$-85$0^{\circ}C$), 중온영역(90$0^{\circ}C$-95$0^{\circ}C$), 고온영역(100$0^{\circ}C$$\leq$)으로 구분되었다. 저온영역에서는 반응온도에 비례해서 침투속도가 증가하였으나, 중간온도 영역은 치환반응에 의해 생성된 알루미나의 상전이에 따른 영향으로 저온영역인 85$0^{\circ}C$에서보다 오히려 침투속도가 감소하였다. 고온영역중 100$0^{\circ}C$이상에서 침투가 일어나지 않는 것은 용융 알루미늄중의 마그네슘이 먼저 실리카와 반응하여 silica preform의 표면에 치밀한 스피넬층을 형성하기 때문으로 판명되었다.

  • PDF

유리섬유강화 복합재료의 표면거칠기에 따른 에폭시 접착제의 접착강도 평가 (Evaluation of Adhesion Property of Epoxy Adhesive with Different Surface Roughness of GFRC)

  • 김종현;신평수;이상일;박종만
    • 접착 및 계면
    • /
    • 제21권1호
    • /
    • pp.27-33
    • /
    • 2020
  • 유리섬유강화 복합재료 (GFRC)의 표면거칠기에 따른 에폭시 접착제의 접착강도를 평가하였고 최적의 표면거칠기를 선정하였다. 서로 다른 입자크기의 알루미나 (Al2O3) 입자를 GFRC의 표면에 분사하였고 이를 통하여 서로 다른 표면거칠기를 부여하였다. 표면거칠기를 정량화 하였고 표면거칠기에 따른 표면관찰을 진행하였다. 각 표면거칠기에 따른 접촉각을 측정하였고 이를 통하여 표면에너지를 계산하였으며, 에폭시 접착제와의 접착일을 계산 및 비교하여 접착력을 예측하였다. 단일랩전단 시험을 통해 접착강도를 평가하였고 거칠기에 따라 접착강도가 증가된다는 것을 확인하였다. 박리 후 표면을 관찰해 보았을 때 기지재인 GFRC의 박리 정도가 다른 것을 확인하였고 최종적으로 표면거칠기의 최적조건을 확인할 수 있었다.

열변형 저감을 위한 고분자 복합소재 배합 조건에 따른 재료특성 분석 (Analysis of Material Properties According to Compounding Conditions of Polymer Composites to Reduce Thermal Deformation)

  • 변상원;김영신;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.148-154
    • /
    • 2022
  • As the 4th industrial age approaches, the demand for semiconductors is increasing enough to be used in all electronic devices. At the same time, semiconductor technology is also developing day by day, leading to ultraprecision and low power consumption. Semiconductors that keep getting smaller generate heat because the energy density increases, and the generated heat changes the shape of the semiconductor package, so it is important to manage. The temperature change is not only self-heating of the semiconductor package, but also heat generated by external damage. If the package is deformed, it is necessary to manage it because functional problems and performance degradation such as damage occur. The package burn in test in the post-process of semiconductor production is a process that tests the durability and function of the package in a high-temperature environment, and heat dissipation performance can be evaluated. In this paper, we intend to review a new material formulation that can improve the performance of the adapter, which is one of the parts of the test socket used in the burn-in test. It was confirmed what characteristics the basic base showed when polyamide, a high-molecular material, and alumina, which had high thermal conductivity, were mixed for each magnification. In this study, functional evaluation was also carried out by injecting an adapter, a part of the test socket, at the same time as the specimen was manufactured. Verification of stiffness such as tensile strength and flexural strength by mixing ratio, performance evaluation such as thermal conductivity, and manufacturing of a dummy device also confirmed warpage. As a result, it was confirmed that the thermal stability was excellent. Through this study, it is thought that it can be used as basic data for the development of materials for burn-in sockets in the future.

주기가열법을 이용한 탄소/에폭시 및 다공성 단열재의 진공 열확산도 측정 (Thermal Diffusivity Measurement of Carbon/Epoxy and Porous Thermal Insulation Material under Vacuum Condition Using Cyclic Heating Method)

  • 남기원;이영무;;공철원
    • Composites Research
    • /
    • 제20권5호
    • /
    • pp.20-25
    • /
    • 2007
  • 열주기법은 다공성 소재의 열확산도를 측정하는데 유용한 방법이다. 본 논문의 주 목적은 진공환경에서 다공성 소재의 열확산도 측정 시스템을 개발하고 검증하는데 있다. 이 방법을 검증하기 위하여 알루미나 시편과 폴리스티렌 폼의 열확산도를 측정하였다. 이 시편들의 열확산도는 참고값과 일치하였다. 탄소/에폭시 소재와 다공성 단열소재의 열확산도를 대기상온과 대기진공 환경에서 측정하였다. 탄소/에폭시 소재와 다공성 단열소재의 진공환경에서 열확산도는 대기환경에 비하여 각각 66.4%와 64.9% 감소하였다. 이 차이는 소재내의 기공에 있는 공기의 영향으로 추정된다.

Air abrasive technique을 이용한 복합레진 수복 증례 (TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE)

  • 이창우;장기택;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교 (FEA estimates of margin design in all ceramic crowns)

  • 한상현;조정현;이은정;정숙인;오남식
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.1-11
    • /
    • 2008
  • 현대 치의학에서는 환자의 심미적 만족을 충족시키기 위한 지속적인 관심으로 완전 도재관의 발전을 가져왔다. 최근의 연구 결과들은 완전 도재관의 물리적 성질과 마모 저항성, 색조의 안정성 등을 보고하고 있다. 이와 같이 여러 장점이 많음에도 불구하고 아직 파절에 대한 저항성에는 많은 의문점을 내포하고 있다. 구강 내에서 기능적인 교합력은 수복물의 변연에 응력을 주게된다. 이러한 응력은 주변 조직으로 잘 분산되어져야 하는데, 수복물의 변연 형태에 따라 다른 양상을 보여주게 된다. 변연 형태는 수복물의 부피와 모양, 그리고 변연에서의 적합도에도 영향을 주게 된다. 본 연구에서는 완전 도재관에서의 변연 형태에 따른 응력 분포를 3차원 유한 요소 분석법을 이용하여 조사하였다. 상악 중절치가 기본 모델로 사용되었고, 완전 도재관을 재현하였다. 변연 형태로는 $90^{\circ}$ shoulder, $110^{\circ}$ shoulder, $135^{\circ}$ shoulder형태를 부여하고, 100N의 힘을 치축에 $45^{\circ}$ 방향으로 가하였다. 그 결과 도재 내부의 응력 분포는 $90^{\circ}$, $110^{\circ}$ 모델에 비해 변연 각도가 $135^{\circ}$인 모델의 경우가 응력의 분포가 고르게 나타났다. 그러나 변연에서는 $90^{\circ}$$110^{\circ}$ 모델의 응력보다 조금 더 집중되었다. $90^{\circ}$$110^{\circ}$ 모델의 비교시는 대체로 비슷했다. 알루미나 코아 내부의 응력 분포에서도 또한 $135^{\circ}$인 모델이 $90^{\circ}$$110^{\circ}$ 모델의 응력분포보다 더 잘 분포되었다. $90^{\circ}$$110^{\circ}$ 모델의 비교시는 $110^{\circ}$$90^{\circ}$ 모델에 비해 더 좋은 응력분포를 보였다. 알루미나 코아와 접착제 사이의 계면에서는 응력이 변연으로 갈수록 감소하고, 알루미나 코아와 도재 사이의 계면에서는 변연으로 갈수록 응력이 점차 증가하였다. $135^{\circ}$ shoulder는 고른 응력분포임에도 변연에서의 응력 집중이 나타나므로 완전 도재관의 변연으로는 적절하지 못하며, $90^{\circ}$ shoulder보다 상대적으로 좋은 응력분포와 변연 형성의 용이성이 우세한 $110^{\circ}$ shoulder가 완전 도재관의 변연에 추천될 수 있겠다.

불용성 폴리머가 탄소섬유 보강 Polymer-MDF 시멘트 복합재료의 기계적 특성에 미치는 영향 (The Effects of Insoluble Polymers on Water Stability of Carbon Fiber Reinforced Polymer-MDF Cementitious Composites)

  • 김태진;박춘근
    • Composites Research
    • /
    • 제12권3호
    • /
    • pp.84-90
    • /
    • 1999
  • HAC/PVA계 MDF시멘트 복합재료의 수분안정성 및 기계적 강도향상을 위하여 불용성 폴리머류(폴리우레탄, 페놀, 에폭시수지)와 탄소섬유(길이3mm)를 1-4wt% 보강하였다. 그리고 가압성형법으로 제조한 복합체의 수분침적 기간별 강도특성(수분안정성)과 계면 및 기계적 특성에 영향을 미치는 폴리머와 시멘트의 가교반응에 대하여 SEM 및 TEM 분석을 통하여 관찰하였다. HAC/PVA계 MDF 시멘트 복합체의 섬유함량에 따른 건조 굽힘강도는 섬유함량이 증가할수록 치밀화 구조가 저하되어 비례적으로 감소되었다. 또한 불용성 폴리머류를 사용한 경우에 건조 굽힘강도는 섬유함량이 증가될수록 저하되는 반면, 수분안정성은 크게 향상되었다. 에폭시 수지를 첨가한 경우에 수분안정성이 가장 우수하였으며, 섬유함량 4% 첨가의 경우에 3일 침적강도가 95%, 7일침적시 87%강도를 유지하였다. 이 점은 폴리머와 시멘트의 금속이온이 가교반응을 일으켜 섬유-메트릭스간 계면 부착강도를 크게 개선되었기 때문으로 추정된다. 반면 인장강도 특성은 모든 불용성 폴리머류 첨가 수준에서 섬유 함량이 증가할수록 비례적으로 증가되었으며, 역시 에폭시 수지 첨가의 경우에 강도특성이 가장 우수하였다. 그리고 섬유함량 4% 첨가된 경우에 있어서 인장강도는 섬유함량 0% 대비 약 30~80% 높게 나타났다.

  • PDF

붕소를 함유하지 않는 E-glass fiber의 제조 및 특성에 대한 연구 (Fabrication and characterization of boron free E-glass fiber compositions)

  • 이지선;임태영;이요셉;이미재;황종희;김진호;현승균
    • 한국결정성장학회지
    • /
    • 제23권1호
    • /
    • pp.44-50
    • /
    • 2013
  • E-glass 섬유는 항공기, 자동차, 레져기구의 복합재료 보강용으로 가장 널리 사용되는 유리섬유이다. 그러나 최근 E-glass 섬유의 원재료비 상승, 환경문제 및 화학적 저항성과 기계적 특성을 향상시키기 위해 산화붕소 함량을 8 %에서 0(제로)까지 감소시키는(소위 'Boron free E-glass'라고 불리는) 연구가 진행되고 있다. 본 연구에서는 'BF(Boron free E-glass)' 조성의 벌크유리와 섬유유리를 제조하고, 열적특성 및 광학적특성을 평가하였다. 5~10 %의 서로 다른 알루미나 함량을 갖는 배치를 $1550^{\circ}C$에서 2시간 용융하여 'BF(Boron free E-glass)'가 얻어졌고, 81~86 %의 높은 가시광투과율, $4.2{\sim}4.9{\times}10^{-6}/^{\circ}C$의 낮은 열팽창계수, $907{\sim}928^{\circ}C$의 연화점을 갖는 투명하고 맑은 유리가 얻어졌다. 'BF' 섬유 시편에 대한 화학적내구성 시험에 있어서는 알루미나 함량이 높아질수록 더 좋은 침식저항성을 나타냄을 확인할 수 있었다.

샌드블라스팅과 프라이머가 지르코니아와 레진시멘트의 전단결합강도에 미치는 영향 (Influence of sandblasting and primer on shear bond strength of resin cement to zirconia)

  • 이정행;김형섭;배아란;우이형
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.49-56
    • /
    • 2011
  • 연구 목적: 최근 지르코니아가 전부도재관의 코어로 많이 사용되고 있다. 지르코니아와 레진 시멘트의 결합 강도를 높이기 위한 기계적, 화학적인 표면 처리 방법들이 연구되고 있다. 이 연구에서 여러 표면 처리 방법에 따른 지르코니아와 레진 시멘트의 전단결합강도를 알아보고자 한다. 연구 재료 및 방법: 80개의 지르코니아 (Lava, 3M ESPE, St. Paul, MN, USA) 시편과 80개의 지르코니아/알루미나 복합체 (Zirace, Acucera Co Inc, Korea) 시편을 디스크형태로 제작하여 에폭시레진에 매립하였다. 이들을 각각 4개의 군으로 나누어 $50\;{\mu}m$ $Al_2O_3$ sandblasting, $110\;{\mu}m$ $Al_2O_3$ sandblasting, $50\;{\mu}m$ $Al_2O_3$ sandblasting과 프라이머 (Z-PRIME Plus, Bisco Inc, Schaumburg, IL, USA) 사용, $110\;{\mu}m$ $Al_2O_3$ sandblasting과 프라이머 (Z-PRIME Plus) 사용 군으로 나누었다. 표면 처리한 지르코니아 표면에 2가지 레진 시멘 (Calibra, Panavia F)으로 접착하였다. 그 후 증류수 ($37^{\circ}C$)에 24시간 보관 후 전단 결합 강도 실험을 시행하였고, SEM을 사용하여 표면 처리한 표면과 전단강도 실험 후 파절양상을 관찰하였다. 결과: ANOVA분석에 따르면, 두 가지 종류의 시편 모두에서, 프라이머 (Z-PRIME Plus)를 사용하여 표면 처리한 군들이 전단 결합 강도가 높았다 (P < .05). 결론: 기계적 결합 강도와 함께 새로운 프라이머를 사용하는 것이 지르코니아와 레진 시멘트의 접착 강도를 증가시킨다.