구조물-비구조요소 2자유도 결합시스템 해석을 통한 비구조요소 내진설계변수 평가 (Evaluation of Seismic Design Parameters for Nonstructural Components Based on Coupled Structure-Nonstructural 2-DOF System Analysis)

  • 배창준;이철호;전수찬
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.105-116
    • /
    • 2022
  • Seismic demand on nonstructural components (NSCs) is highly dependent on the coupled behavior of a combined supporting structure-NSC system. Because of the inherent complexities of the problem, many of the affecting factors are inevitably neglected or simplified based on engineering judgments in current seismic design codes. However, a systematic analysis of the key affecting factors should establish reasonable seismic design provisions for NSCs. In this study, an idealized 2-DOF model simulating the coupled structure-NSC system was constructed to analyze the parameters that affect the response of NSCs comprehensively. The analyses were conducted to evaluate the effects of structure-NSC mass ratio, structure, and NSC nonlinearities on the peak component acceleration. Also, the appropriateness of component ductility factor (Rp) given by current codes was discussed based on the required ductility capacity of NSCs. It was observed that the responses of NSCs on the coupled system were significantly affected by the mass ratio, resulting in lower accelerations than the floor spectrum-based response, which neglected the interaction effects. Also, the component amplification factor (ap) in current provisions tended to underestimate the dynamic amplification of NSCs with a mass ratio of less than 15%. The nonlinearity of NSCs decreased the component responses. In some cases, the code-specified Rp caused nonlinear deformation far beyond the ductility capacity of NSCs, and a practically unacceptable level of ductility was required for short-period NSCs to achieve the assigned amount of response reduction.

건축 비구조재의 내진설계요소 및 내진설계하중에 관한 고찰 (Investigation on Seismic Design Component and Load for Nonstructural Element)

  • 최인섭;이주희;손정훈;김준희
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.117-124
    • /
    • 2019
  • Nonstructural elements are installed according to the function of a building, and refer to the elements other than a structural system that resists external loads. Although the nonstructural elements had the largest part of seismic loss of buildings, seismic design of buildings mainly focuses on structural system and the seismic design of nonstructural elements are rarely conducted. In this study, the seismic design provisions of nonstructural elements presented in Uniform Building Code (UBC) and International Building Code (IBC) were investigated in order to analyze the seismic design considerations of nonstructural elements presented in Korean Building Code (KBC). The results showed that the equivalent static load applied to seismic design of nonstructural elements was revised to take into consideration a total of five items such as effective ground acceleration, vertical amplification factor, response amplification factor, response modification factor, importance factor.

구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수 (Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes)

  • 임승현;최인길;전법규;곽신영
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Evaluation of seismic design provisions for acceleration-sensitive non-structural components

  • Surana, Mitesh
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.611-623
    • /
    • 2019
  • A set of mid-rise bare and uniformly infilled reinforced-concrete frame buildings are analyzed for two different seismic intensities of ground-motions (i.e., 'Design Basis Earthquake' and 'Maximum Considered Earthquake') to study their floor response. The crucial parameters affecting seismic design force for acceleration-sensitive non-structural components are studied and compared with the guidelines of the European and the United States standards, and also with the recently developed NIST provisions. It is observed that the provisions of both the European and the United States standards do not account for the effects of the period of vibration of the supporting structure and seismic intensity of ground-motions and thereby provides conservative estimates of the in-structure amplification. In case of bare frames, the herein derived component amplification factors for both the design basis earthquake and the maximum considered earthquake exceeds with their recommended values in the European and the United States standards for non-structural components having periods in vicinity of the higher modes of vibration, whereas, in case of infilled frames, component amplification factors exceeds with their recommended value in the European standard for non-structural components having periods in vicinity of the fundamental mode of vibration, and only for the design basis earthquake. As a consequence of these observations, as well as capping on the design force (in case of United states standard and NIST provisions), in case of the design basis earthquake, the combined amplification factor is underestimated for non-structural components having periods in vicinity of the higher modes of vibration of bare frames, and also for non-structural components having periods in vicinity of the fundamental mode of vibration of infilled frames. At the maximum considered earthquake demand, excepting non-structural components having periods in vicinity of the higher modes of vibration of bare frames, all provisions generally provide conservative estimates of the design floor accelerations.

비틀림 비정형 건물의 내진설계를 위한 우발편심 비틀림 증폭계수 검증 (Verification of the Torsional Amplification Factor for the Seismic Design of Torsionally Imbalanced Buildings)

  • 이광호;정성훈
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.67-74
    • /
    • 2010
  • 건물의 실제 편심은 일반적으로 계산된 값과 상당히 다르며, 정형 건물도 비틀림의 영향을 받는다. 질량분포의 비대칭성과 수직축에 대한 지반의 회전요소와 같은 요인들의 영향을 고려하고, 비틀림 비정형 건물의 취약성을 줄이기 위하여 내진설계규준에서는 우발편심과 비틀림 증폭계수를 도입하였다. 본 연구에서는 정형건물의 다양한 형상비와 평면중심으로부터의 부재위치에 따른 비틀림 증폭계수의 영향 및 이 계수에 영향을 미치는 요인을 확인하였고 보통암 지반에 위치한 다양한 편심과 형상비를 갖는 비선형 철근콘크리트 단층모델을 이용하여 비틀림 증폭계수를 검증하였다. 비선형 정적해석과 시간이력해석을 이용하여 구한 연약단부의 최대 정적변위와 동적변위는 비교적 일치하였으나 최대 정적비틀림과 동적비틀림의 차이는 편심크기가 작을수록 크게 나타났다. 1차 설계편심에 비틀림 증폭계수 적용유.무에 따라 연약단부 부재의 밑면전단력 증가가 미비하여 최대 정적변위의 증가비가 크지 않다.

Elastic floor response spectra of nonlinear frame structures subjected to forward-directivity pulses of near-fault records

  • Kanee, Ali Reza Taghavee;Kani, Iradj Mahmood Zadeh;Noorzad, Assadollah
    • Earthquakes and Structures
    • /
    • 제5권1호
    • /
    • pp.49-65
    • /
    • 2013
  • This article presents the statistical characteristics of elastic floor acceleration spectra that represent the peak response demand of non-structural components attached to a nonlinear supporting frame. For this purpose, a set of stiff and flexible general moment resisting frames with periods of 0.3-3.6 sec. are analyzed using forty-nine near-field strong ground motion records. Peak accelerations are derived for each single degree of freedom non-structural component, supported by the above mentioned frames, through a direct-integration time-history analysis. These accelerations are obtained by Floor Acceleration Response Spectrum (FARS) method. They are statistically analyzed in the next step to achieve a better understanding of their height-wise distributions. The factors that affect FARS values are found in the relevant state of the art. Here, they are summarized to evaluate the amplification and/or reduction of FARS values especially when the supporting structures undergo inelastic behavior. The properties of FARS values are studied in three regions: long-period, fundamental-period and short-period. Maximum elastic acceleration response of non-structural component, mounted on inelastic frames, depends on the following factors: inelasticity intensity and modal periods of supporting structure; natural period, damping ratio and location of non-structural component. The FARS values, corresponded to the modal periods of supporting structure, are strongly reduced beyond elastic domain. However, they could be amplified in the transferring period domain between the mentioned modal periods. In the next step, the amplification and/or reduction of FARS values, caused by inelastic behavior of supporting structure, are calculated. A parameter called the response acceleration reduction factor ($R_{acc}$), has been previously used for far-field earthquakes. The feasibility of extending this parameter for near-field motions is focused here, suggested repeatedly in the relevant sources. The nonlinearity of supporting structure is included in ($R_{acc}$) for better estimation of maximum non-structural component absolute acceleration demand, which is ordinarily neglected in the seismic design provisions.

Occurrence mechanism of recent large earthquake ground motions at nuclear power plant sites in Japan under soil-structure interaction

  • Kamagata, Shuichi;Takeqaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권5호
    • /
    • pp.557-585
    • /
    • 2013
  • The recent huge earthquake ground motion records in Japan result in the reconsideration of seismic design forces for nuclear power stations from the view point of seismological research. In addition, the seismic design force should be defined also from the view point of structural engineering. In this paper it is shown that one of the occurrence mechanisms of such large acceleration in recent seismic records (recorded in or near massive structures and not free-field ground motions) is due to the interaction between a massive building and its surrounding soil which induces amplification of local mode in the surface soil. Furthermore on-site investigation after earthquakes in the nuclear power stations reveals some damages of soil around the building (cracks, settlement and sand boiling). The influence of plastic behavior of soil is investigated in the context of interaction between the structure and the surrounding soil. Moreover the amplification property of the surface soil is investigated from the seismic records of the Suruga-gulf earthquake in 2009 and the 2011 off the Pacific coast of Tohoku earthquake in 2011. Two methods are introduced for the analysis of the non-stationary process of ground motions. It is shown that the non-stationary Fourier spectra can detect the temporal change of frequency contents of ground motions and the displacement profile integrated from its acceleration profile is useful to evaluate the seismic behavior of the building and the surrounding soil.

Shaking table tests on the seismic response of slopes to near-fault ground motion

  • Zhu, Chongqiang;Cheng, Hualin;Bao, Yangjuan;Chen, Zhiyi;Huang, Yu
    • Geomechanics and Engineering
    • /
    • 제29권2호
    • /
    • pp.133-143
    • /
    • 2022
  • The catastrophic earthquake-induced failure of slopes concentrically distributed at near-fault area, which indicated the special features of near-fault ground motions, i.e. horizontal pulse-like motion and large vertical component, should have great effect on these geo-disasters. We performed shaking table tests to investigate the effect of both horizontal pulse-like motion and vertical component on dynamic response of slope. Both unidirectional (i.e., horizontal or vertical motions) and bidirectional (i.e., horizontal and vertical components) motions are applied to soft rock slope model, and acceleration at different locations is reordered. The results show that the horizontal acceleration amplification factor (AAF) increases with height. Moreover, the horizontal AAF under unidirectional horizontal pulse-like excitations is larger than that subject to ordinary motion. The vertical AAF does not show an elevation amplification effect. The seismic response of slope under different bidirectional excitations is also different: (1) The horizontal AAF is roughly constant under horizontal pulse-like excitations with and without vertical waves, but (2) the horizontal AAF under ordinary bidirectional ground motions is larger than that under unidirectional ordinary motion. Above phenomena indicate that vertical component has limited effect on seismic response when the horizontal component is pulse-like ground motion, but it can greatly enhance seismic response of slope under ordinary horizontal motion. Moreover, the vertical AAF is enhanced by horizontal motion in both horizontal pulse-like and ordinary motion. Thence, we should pay enough attention to vertical ground motion, especially its horizontal component is ordinary ground motion.

국내 광대역 지진 관측소의 부지효과 (The Site Effect of the Broadband Seismic Stations in Korea)

  • 위성훈;김성균
    • 자원환경지질
    • /
    • 제41권2호
    • /
    • pp.225-242
    • /
    • 2008
  • 이 연구에서는 coda파 스펙트럼 비를 이용하여 한반도 남부의 광대역 지진관측소 23개소에 대한 부지효과를 추정하였다. 원리적으로 부지효과는 지진원과 전달과정중의 감쇠효과를 제외한 관측소 하부에서의 순수한 증폭효과만을 의미한다. 그러나 이 연구에서 구한 부지효과는 모든 관측소의 평균값에 대한 상대적인 부지증폭률과 같다. 2001년 1월부터 2007년 1월 사이에 발생한 규모 2.5부터 5.1까지의 지진 35개로부터 기록된 500개의 3성분 파형이 부지증폭효과를 얻기 위해 사용되었다. 부지증폭률은 중심주파수를 0.2, 0.5, 1,2, 5, 10, 15, 및 20 Hz로 하는 주파수대역에 대해서 계산하였다. 횡단성분과 방사성분의 수평 2성분에 대한 부지증폭률은 모든 주파수 대역에서 서로 일치하나, 수직성분의 증폭률은 수평성분에 비하여 일관되게 낮게 나타났다. 또한 증폭률은 저주파 보다는 고주파에서 일반적으로 증폭의 정도가 큰 경향을 보였다. 부지증폭률은 2 Hz 이하의 저주파에서 1.5 이상의 높은 값을 갖는 기상청과 한국지질자원연구원의 백령도 관측소(BRD1과 BRD2)를 제외한 나머지 관측소에서 0.5와 1.5사이의 값을 갖는다. SEO, SNU, HKU, NPR 및 GKP1 관측소들은 5${\sim}$20Hz범위의 고주파 대역에서 1.5 이상의 높은 값을 보였으며, 특히 GKP1 관측소는 1.8${\sim}$7.8 범위의 높은 증폭값이 나타났다. 또한 KWJ, SND 및 ULJ 관측소는 0.5이하의 낮은 값을 나타내었다. 부지증폭률의 공간적 분포는 한반도 남부에서 대체로 북동부가 남서부에 비해 증폭의 정도가 낮은 경향을 보여 준다.

Spectrum Sensing and Data Transmission in a Cognitive Relay Network Considering Spatial False Alarms

  • Tishita, Tasnina A.;Akhter, Sumiya;Islam, Md. Imdadul;Amin, M. Ruhul
    • Journal of Information Processing Systems
    • /
    • 제10권3호
    • /
    • pp.459-470
    • /
    • 2014
  • In this paper, the average probability of the symbol error rate (SER) and throughput are studied in the presence of joint spectrum sensing and data transmission in a cognitive relay network, which is in the environment of an optimal power allocation strategy. In this investigation, the main component in calculating the secondary throughput is the inclusion of the spatial false alarms, in addition to the conventional false alarms. It has been shown that there exists an optimal secondary power amplification factor at which the probability of SER has a minimum value, whereas the throughput has a maximum value. We performed a Monte-Carlo simulation to validate the analytical results.