• Title/Summary/Keyword: Complex permeability

Search Result 228, Processing Time 0.025 seconds

Electromagetic Wave Absorbing Properties of $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$(X=Cu, Mg, Mn)-Rubber Composite ($Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$(X=Cu, Mg, Mn)-Rubber Composite의 전파흡수특성에 관한 연구)

  • Im, Hui-Dae;Yun, Guk-Tae;Lee, Chan-Gyu
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1234-1239
    • /
    • 1999
  • Electromagnetic wave asorbing properties of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$, where X was replaced by substitution elements Cu, Mg, Mn, have been studied. The structure, shape, size and magnetic properties of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$ were analyzed by XRD, SEM, VSM. The relative complex permittivity, permeability, and electromagnetic wave absorbing properties were measured by Network Analyzer. The structure, shape, size and magnetization value of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$ were found to be similar in spite of substitution elements. The coercive force and hysteresis-loss showed maximum value when Mg was substituted for X. The dielectric loss(${\varepsilon}_r"/{\varepsilon}_r'$) was found to be maximum value when Mn was substituted for X. Also the magnetic loss(${\mu}_r"/{\mu}_r'$} was found to be maximum with Cu substitution. The electromagnetica wave absorbing property of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$-Rubber composite with 4mm thickness was excellent as over - 40dB at 9GHz, and the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$-Rubber composite with 8mm thickness was over-40dB at 2GHz. Those composites also showed superior microwave absorbing properties.

  • PDF

Analysis of the Spatial Effect of Gated Communities and Improvement of Urban Publicness (게이티드 커뮤니티의 공간적 영향 분석 및 도시 공공성 개선방안)

  • KIM, JiSook;KIM, Ho-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.150-163
    • /
    • 2022
  • Recently, the gated community has been increasing due to various reasons such as demand for differentiated areas and security, but various problems have been raised, including regional conflicts, traffic restrictions and disconnection of surrounding areas. Therefore, this study empirically considered what kind of spatial effect the gated community has on the surrounding area by analyzing the vitality using floating population big data and analyzing pedestrian accessibility using network analysis and social network analysis. As a result, it was found that the overall vitality in the study area was greatly affected by the land use and the building use. However, focusing on apartment complexes, even in the same land use, when the form of the complex is open to the outside, there is a lot of floating population, so the vitality is high. In terms of accessibility, assuming that the gated community is open, it was found that as the physical connectivity improved, there were more roads for pedestrians to choose from, and the accessibility improved as traffic and exchanges occurred in the disconnected space. The value of improving property rights and residential environment is also precious, but it is necessary to review how to reflect the improvement of local permeability in enhancing the publicness of cities and the value and direction of communities that can coexist with the region.

Geotechnical Hybrid Simulation System for the Quantitative Prediction of the Residual Deformation in the Liquefiable Sand During and After Earthquake Motion (액상화 가능 지반의 진동 도중 및 후의 잔류 변형에 대한 정량적 예측을 위한 하이브리드 시뮬레이션 시스템)

  • Kwon, Young Cheul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1C
    • /
    • pp.43-52
    • /
    • 2006
  • Despite several constitutive models have been proposed and applied, it is still difficult to choose a suitable model and to estimate adequate analysis parameters. Furthermore, a cyclic shear behavior under the volume change caused by the seepage is more complex. None of the constitutive model is available at present in the expression of the cyclic behavior of soil under an additional volume change condition by seepage. Therefore, a new geotechnical hybrid simulation system which can control the pore water immigration was developed. The system enables a quantitative evaluation of the residual deformation such as lateral spreading and settlement caused by the liquefaction. The seismic responses in a one-dimensional slightly inclined multilayered soil system are taken into consideration, and the soils are governed by both equation of motion and the continuity equation. Furthermore, the estimation and the selection of the soil parameter for the representation of the strong nonlinearity of the material are not required, because soil behaviors under the earthquake motions are directly introduced instead of a numerical soil constitutive model. This paper presents the concept and specifications of the system. By applying the system to an example problem, the permeability effect on the seismic response during cyclic shear is studied. The importance of the volume change characteristics of sandy soil during and after cyclic shear is shown in conclusion.

Effect of Calcination Temperature on Electromagnetic Wave Absorption Properties of M-type Ferrite Composite (하소온도가 M형 페라이트 복합재의 전자파 흡수 특성에 미치는 영향)

  • Seong Jun Cheon;Jae Ryung Choi;Sang Bok Lee;Je In Lee;Horim Lee
    • Composites Research
    • /
    • v.36 no.5
    • /
    • pp.289-296
    • /
    • 2023
  • In this study, we investigated the electromagnetic properties and microwave absorption characteristics of M-type hexagonal ferrites, which are known as millimeter-wave absorbing materials, according to their calcination temperature. The M-type ferrites synthesized using a molten salt-based sol-gel method exhibited a single-phase M-type crystal structure at calcination temperatures above 850℃. The synthesized particle size increased as well with the calcination temperature. Saturation magnetization increased gradually with increasing calcination temperature, but coercivity reached a maximum at 1050℃ and then rapidly decreased. After preparing a thermoplastic polyurethane (TPU) composite containing 70 wt% of M-type ferrites, we measured the complex permittivity and permeability in the Q-band (33-50 GHz) and V-band (50-75 GHz) frequency ranges, where ferromagnetic resonance occurred. Strong magnetic loss from ferromagnetic resonance occurred in the 50 GHz band for all composite samples. Based on the measured results, we calculated the reflection loss of the TPU/M-type ferrite composite. By calculating the reflection loss of the M-type ferrite composite, the M-type ferrite calcined at 1250℃ showed excellent electromagnetic wave absorption performance of more than -20 dB at 52 GHz with a thickness of about 0.5 mm.

A Study on the Structure Characteristics of Planting Ground in Incheon International Airport, Korea (인천국제공항 식재기반 구조 및 토양특성 연구)

  • Lee, Seung-Won;Han, Bong-Ho;Lee, Kyong-Jae;Kwak, Jeong-In;Yeum, Jung-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.77-91
    • /
    • 2015
  • This study aims to suggest adequate soil management through the analysis of physicochemical properties of soil in the planting grounds of Incheon International Airport, which was constructed on a massive land reclamation site. Study areas were 5 sites at the international business complex, the passenger terminal, the airport support complex, the free trade zone, and the access road. Soil profile analysis showed that 9 plots out of the 27 plots were hardpan and heterospere within 80cm from the soil surface. The earth laid on the ground was categorized as gravel based soil(4 plots), dredged soil from the sea bottom and mixed reclamation materials(2 plots), clay with poor permeability(3 plots) and waste construction material(1 plot). Average soil hardness was $11.5kg/cm^2$ and soil textures were sandy soil, sandy loam and loamy sand. Average soil pH was 6.7 and average organic matter content was 0.7%. Electrical conductivity was 0.0dS/m and exchangeable cation concentrations were $Ca^{2+}$ 3.4cmol/kg, $Mg^{2+}$ 1.5cmol/kg, $K^+$ 0.3cmol/kg and $Na^+$ 1.0cmol/kg. Average cation exchange capacity was 11.0cmol/kg. Although average figures in Solum mostly meet the landscape design criteria, properties of each soil layer showed various values sometimes over the limit. Base saturations were $Ca^{2+}$ 29.9%, $Mg^{2+}$ 13.3% and $K^+$ 3.7% for lower soil, $Ca^{2+}$ 33.3%, $Mg^{2+}$ 17.0% and $K^+$ 2.7% for mid-soil and $Ca^{2+}$ 32.6%, $Mg^{2+}$ 12.2% and $K^+$ 1.9% for upper soil. Exchangeable sodium percentages were 16.4% for lower soil, 7.5% for mid-soil and 4.7% upper soil. Sodium adsorption rates were 0.8 for lower soil, 0.3 for mid-soil and 0.2 for upper soil. Factors affecting to the vegetation growth were heterogeneity and poorness of solum, disturbance of dredged soils, high soil hardness including hardpan in the subsurface soil layer and shallow effective soil depth, high soil acidity, imbalance of base contents, low organic matter content and low available phosphate levels in the soil.

Autoradiographic Studies on the Inhibitory Effect of Dibutyryl Cyclic AMP on Mouse Oocyte Maturation in Vitro (Dibutyryl Cyclic AMP가 생쥐여포난자의 성숙에 미치는 억제효과에 관한 자기방사법적 연구)

  • Choi, Choon-Keun
    • Applied Microscopy
    • /
    • v.7 no.1
    • /
    • pp.21-43
    • /
    • 1977
  • This experiment was undertaken in order to localize the labeled dbcAMP (dibutyryl cyclic AMP) in oocytes whose development has been suppressed by cold dbcAMP for 6 or 19 hours in vitro. Mouse oocytes were obtained from the ovaries of 3-4 week old A strain female mice, by puncturing the Graafian follicles in the modified Krebs-Ringer bicarbonate salt solution under the dissecting microscope. Those oocytes which have intact germinal vesicle were cultured in the basic culture medium supplemented with 0.4% bovine serum albumin (BSA). Cultivation of the oocytes was carried out in a microtube developed by Cho (1974). The cultures were then incubated in a humidified 5% $CO_2$ incubator maintained at $37^{\circ}C$ for 6 or 19 hours (Donahue, 1968). DbcAMP was added to culture medium for a final concentration of 100ug/ml, and $^3H-dbc$ AMP (specific activity 13 Ci/mM) for a final concentration of $40{\mu}Ci/ml$ was also added to the medium. For electron microscopic autoradiography, those oocytes recovered from the culture were washed with phosphate buffer (pH 7.4), and immediately prefixed in a 2.5% glutaraldehyde overnight and postfixed for 2 hours at $4 ^{\circ}C$ in 1% osmium tetroxide in phosphate buffer with pH 7.4 (Palade, 1952). After fixation, the materials were dehydrated in graded alcohol series and embedded in Epon 812 mixture based on the standard procedures (Luft, 1961). The thin sections $600-700{\AA}$ thick were mounted on the grids of 200 meshes. The grids containing sections were coated with a nuclear emulsion Kodak NTB-3 and stored in a cold dark box (at $4^{\circ}C$) for 3 weeks. After exposure, the samples were developed with Kodak D-19 and stained with uranyl acetate and lead citrate. Routine observation was made with Hitachi HU-11E electron microsocope. The results of the observation were as followings: 1. It was found that the labeled dbcAMP penetrated the egg plasma membrane and dispersed at random in the cytoplasm. 2. It was also observed that most of the labeled dbcAMP was attached to microfibrillar lattices portion of the oocyte cytoplasm. There fore, it is presumed that the receptor of the dbcAMP is localized in the microfibrillar lattices of the oocyte. 3. It also seems that some other cell organells such as mitochondria, Golgi complex, cortical granules are not directly related to the action of the dbcAMP. 4. The labeled dbcAMP was neither observed in the membrane nor in the nucleus. Therefore, it seems that there is no relationship between the concentration of dbcAMP and the nuclear membranous permeability. 5. There was no difference in number of dbcAMP particles when oocytes were cultured for 6 hours and 19 hours. 6. However, it was observed that, in same of the oocytes suppressed in germinal vesicle by dbcAMP for 19 hours, cell organells were moved and concentrated to a small portion of the cytoplasm, and that the morphology of the organells greatly changed to an abnormal. form. Therefore, it is supposed that those oocytes were in the process of degeneration. From the above results, it is expected that dbcAMP penetrated the egg membrane and was bound to the receptor which seems to be located in the microfibrillar lattiees portion, and that this dbcAMP-receptor complex inhibited some enzyme system of the oocytes which are essential for the germinal vesicle breakdown.

  • PDF

Tectonic Structures and Hydrocarbon Potential in the Central Bransfield Basin, Antarctica (남극 브랜스필드 해협 중앙분지의 지체구조 및 석유부존 가능성)

  • Huh Sik;Kim Yeadong;Cheong Dae-Kyo;Jin Young Keun;Nam Sang Heon
    • The Korean Journal of Petroleum Geology
    • /
    • v.5 no.1_2 s.6
    • /
    • pp.9-15
    • /
    • 1997
  • The study area is located in the Central Bransfield Basin, Antarctica. To analyze the morphology of seafloor, structure of basement, and seismic stratigraphy of the sedimentary layers, we have acquired, processed, and interpreted the multi-channel seismic data. The northwest-southeastern back-arc extension dramatically changes seafloor morphology, volcanic and fault distribution, and basin structure along the spreading ridges. The northern continental shelf shows a narrow, steep topography. In contrast, the continental shelf or slope in the south, which is connected to the Antarctic Peninsula, has a gentle gradient. Volcanic activities resulted in the formation of large volcanos and basement highs near the spreading center, and small-scale volcanic diapirs on the shelf. A very long, continuous normal fault characterizes the northern shelf, whereas several basinward synthetic faults probably detach into the master fault in the south. Four transfer faults, the northwest-southeastern deep-parallel structures, controlled the complex distributions of the volcanos, normal faults, depocenters, and possibly hydrocarbon provinces in the study area. They have also deformed the basement structure and depositional pattern. Even though the Bransfield Basin was believed to be formed in the Late Cenozoic (about 4 Ma), the hydrocarbon potential may be very high due to thick sediment accumulation, high organic contents, high heat flow resulted from the active tectonics, and adequate traps.

  • PDF

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.