• 제목/요약/키워드: Complex Installation

검색결과 324건 처리시간 0.026초

A Study of General AC Machine Modeling with Matrix Vector Using DQ Transformation

  • Hong, Sun-Ki
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.98-104
    • /
    • 2013
  • AC machines are in wide use in industry and d-q transformation from 3 phase of a, b, c is commonly used to analyze these kinds of machines. The equivalent circuits of d and q axis are, however, generally cross coupled and difficult to analyze. In this study, a modeling technique of AC machine including induction and PM synchronous motors using matrix vector is proposed. With that model, it can not only explain the AC machines physically but also make it simple to analyze them. The separating process of d and q components is not needed in this model and this model can be applied to analyze asymmetric motors like IPMSM machine. With this technique, the model becomes simple, easy to understand physically, and yields results that are the same as those from other models. These simulation results of the proposed model for induction motor are compared with those of other models to verify the method proposed.

인코히어런트 삼각 홀로그래피에서 위상오차가 횡축방향의 해상도에 미치는 영향에 관한 연구 (Effect of Phase Error on the Lateral Resolution of Reconstruction Image in Incoherent Triangular Holography)

  • 김수길
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.1-6
    • /
    • 2013
  • It is introduced the phase error sources of a incoherent hologram in incoherent triangular holography and derived the reconstruction image of point-source including the phase error in the lateral direction. From the reconstruction image of point-source, we analyzed the effect of phase error on the lateral resolution. When the phase retardation errors and azimuth angle error of a wave plate and a polarizer range from 0 to $2{\pi}/15$, the normalized intensities of reconstructed images are down by about 0.1% and 2.3%, respectively.

배전용 CV케이블의 현장 열화진단 결과의 고찰 (A Study on the Results of the diagnosis of Insulation Deterioration in Live-Line Distribution Power Cables at the Field)

  • 유성종;전승익;정석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1831-1834
    • /
    • 1996
  • Diagnosis of cable insulation degradation has important meaning from a viewpoint of reliability enhancement of CV cable systems. So, we diagnosed 3.3kV & 6.6kV CV distribution cable on live-line which is judged to a most poor installation condition because they have been used in water condition after installation at the Yeochon chemical complex. The paper describes the analysis of the measured data, the problems at diagnosis, and the items which are considered at the development of diagnosis technology and equipment hearafter.

  • PDF

광속법을 이용한 등배치 설계에 관한 연구 (A Study On the Design of Balaced Illuminance Using Lumen Flux Method)

  • 최홍규;최병숙;정성윤;김진성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.175-180
    • /
    • 1999
  • This paper presents the effective design of the change of average illuminance and the arrangement of lamps by changing the form of working area and adjusting the distance between the wall and light. This study is intended to simplify the complex calculation of illuminance through the development of application program. It's plan to study application programs that can attain the value of advanced uniformly-distributed illuminance and average illuminance by changing the distance between the horizontal/vertical wall and lamp and between the horizontal/vertical lamp and lamp.

  • PDF

AC 서보 전동기 시스템의 상태공간 모델 식별에 관한 연구 (A Study on State-Space Model Identification of AC Servo Motor System)

  • 이태훈;김상환;송봉철;원충연;이상석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.199-204
    • /
    • 2000
  • Generally, The systems are so complex that it not possible to obtain reasonable model using physical insight. Also a model based on physical insight contains a number of unknown parameters even if the structure is derived from physical laws. To solve these problems, the systems identification is described in this paper. So, AC servo motor system which has both open loop and closed loop is selected as an example for identification. A state-space model of AC servo motor system is identified through open loop experiment and identified through closed loop experiment and using pole placement integral controller to open loop system. As the results, From ARMA model, We have obtained continuous-time state space model.

  • PDF

공기 및 복합유전체 갭에서의 방사전자파의 거리 및 편파특성 (The distance and polarization characteristics of electromagnetic wave radiated at needle-to-plane electrodes in Air and complex dielectric)

  • 김충년;이현동;박광서;박원주;이광식;이동인;이동헌
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.241-245
    • /
    • 2000
  • In this paper, VHF(30~230[MHz]) electromagnetic waves radiated from partial discharge(PD) at two-type electrodes in air are measured and the peculiar patterns of their spectra are reported. Also, the polarization and distance characteristics of electromagnetic wave rediated by PD, were investigated. In case of epoxy insulator in inserted, the noise level of radiated electromagnetic waves is 0.6~6.2[dB] higher than the case in air at below 90[MHz]. The frequency spectrum distribution of radiated electromagnetic waves appears different in the whole frequency range according to the arrangement of antenna.

  • PDF

공동주택에서의 전기자동차 충전기 수용률 설정과 그 제어방법 (Set up a Demand Factor of EV Chargers and Its Control Method in Apartments)

  • 김명수;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.98-105
    • /
    • 2014
  • In this paper, we have analyzed the power consumption property of EVs(Electric Vehicles) chargers established in a public place, proposed reasonable demand factors by the number of established EV chargers and its control method in apartments. The optimization of power system and the suppression of the peak load can be controlled through the proposed demand factors and charging scheduling control algorithm. In this paper, electrical design and an case analysis were carried out on a sample apartment complex to prove the effectiveness of the power system. As a result, emergency power transformer capacity has been reduced by approximately 25%, and we have confirmed that the electric rates saving and the control of peak load value is possible.

프로운라움 공간특성에서 나타나는 디지털 조명의 확장적 의미 (An Analysis on the Meaning of Digital light as the Spatial Characteristics of Proun Raum)

  • 정근영;김유신;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 2008
  • Light is the essential element for people to live and do creative activities in architecture. The meaning of light has been changed as time has changed, and today it has more sophisticated roles. The meaning of light was to create static ambience in the past but it can create dynamic ambience currently. The digital light can be a source which creates this dynamic effects such as a human behavior, thought and weather data, and also creates new realm of spatial experience such as the metaphysical. complex, and illusionary space. These characteristics can be revealed from Proun raum spatial characteristics. This study analyzes the characteristics of proun raum, and also compare such characteristics to the variable meanings of digital light.

  • PDF

매설형 하이드로폰 시스템의 구조-음향 연성 해석 (Structural-acoustic Coupled Analysis of Buried Hydrophone System)

  • 서희선;조요한;조치영
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.797-804
    • /
    • 2007
  • A study was carried out to investigate the fluid-structure interaction phenomena of buried hydrophone system that exposed complex loads due to handling, transportation and installation. The buried hydrophone system has necessarily neighborhood structures for installation. Because of the neighborhood structure, acoustic field is deformed. We analyze the piezoelectric-structural-acoustic coupled problem and the results to use a finite element analysis software, ANSYS, which has an coupled field analysis capability. The effect of the component of hydrophone system is revealed altogether in pressure distribution. So, we classify and analyze the problem by four different compositions for decomposition.

방음터널 내부의 상부배출구 간격에 따른 CO 농도분포 특성 (The CO Gas Concentration Characteristics in a Sound Proof Road Tunnel According to the Upper Opening Installation Distance Interval)

  • 박명식
    • 한국분무공학회지
    • /
    • 제21권3호
    • /
    • pp.162-169
    • /
    • 2016
  • When we construct a road near an apartment complex, we consider a soundproof wall. To make residential places quieter, we may consider a soundproof road tunnel. Such a tunnel, however, would become highly concentrated with soot from vehicles whenever a traffic jam might occur. To create an optimum design, this study utilizes the PHOENICS-VR software. The work considers three cases: (1) no openings (2) openings at 30m intervals, and (3) openings at 60m intervals on the upper side of the tunnel. The study finds that in the second case shows CO concentration distributions were 15% less than those without openings. And the CO concentration distributions of the second and third cases are almost the same. The findings suggest that we should make the soundproof tunnel to reduce construction fees.