Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher (제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

Eddy current compensation using a gradient system modeling in MR Spiral scan imaging (MR Spiral scan 영상에서 Gradient system의 모델링을 이용한 Eddy current compensation)

  • Cho, S.H.;Kim, P.K.;Kang, S.W.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.339-340
    • /
    • 2007
  • Gradient system에 spiral waveform 입력을 가하면 Hardware limitation에 의하여 만들어지는 gradient fields에 Transient time delay가 발생한다. 이를 보상하기 위하여, Gradient system을 R-L-C 회로로 모델링하여 재구성에 필요한 k-space trajectory를 보정하여 개선된 image를 획득하였다.

  • PDF

A Study Compensation Method for Dynamic Characteristics in Electro-Hydraulic Servosystem Equipping Load Pressure Feedback Compensator (부하압력 피이드백 보상기를 장착한 전기-유압서보계의 동특성 개선에 관한 연구)

  • Kim, Jong-Kyum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.126-136
    • /
    • 1992
  • In this paper, a simple structured feedback compensation scheme for a electro-hydraulic servo system to keep the response characteristics unchanged regardless of the load variation is proposed. In electro-hydraulic servo system, servovalve is most important control element. But the relation between input corrent and output flowrate of the servovalve has properties as follows; firstly, in spite of constant input current, output flowrate decreases as load pressure increases, secondly, according to frequency response of typical servovalve, the characteristics of gain and phase shift is something like 2'nd order system. Load pressure feedback compensation method has been applied to eliminate the first influence, the second influence has been improved by phase lead compensation method. As a result of above compensation methods, regardless of variation load condition, spring and inertia load, the compensation scheme has been verified to be effective within the range of frequency less than 25Hz by static response and dynamic response in time domain and frequency domain through experiments.

  • PDF

CONTROL STRATEGIES FOR SHUNT ACTIVE POWER FILTERS IN DISTORTION SOURCE VOLTAGE SITUATION

  • Yang, Jun;Wang, Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.876-881
    • /
    • 1998
  • The compensation strategy of shunt active power filters is one of the most important link that determine its compensation characteristics. In this paper, a new interpretation of the instantaneous reactive power theory in three-phase circuits was proposed. A compensation strategy (ip, iq mode) was introduced on the basis of the new interpretation. This compensation strategy was compared with other two compensation strategies(P, q mode and UPF mode). When source voltage is distorted, a sinusoidal, the three compensation strategies are equivalent to each other. When source voltage is distorted, a sinusoidal source current may result only by using ip, iq mode. This is the advantage of ip, iq mode. The result is verified by simulation.

  • PDF

A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation (전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구)

  • Oh, Jae-Hoon;Han, Yoon-Seok;Kim, Young-Seok;Won, Chung-Yuen;Choi, Se-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

The Susceptance Control of a STATCOM for Load Compensation and Voltage Regulation (부하보상 및 전압안정을 위한 STATCOM의 서셉턴스 제어)

  • Lim, Su-Saeng;Lee, Eun-Woong;Lim, Yong-Bin;Kim, Hong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.21-23
    • /
    • 1999
  • The alternative precise method for voltage balancing and load compensation using the susceptances control of a STATCOM is discussed. With the control of STATCOM's output current, it is confirmed that the compensation susceptances can be variable. And then the STATCOM's control method about compensation susceptances for load compensation and voltage balancing/regulation is derived. Finally, the effectiveness of load compensation and voltage balancing/regulation is confirmed through computer simulation.

  • PDF

Average Current Mode Control for LLC Series Resonant DC-to-DC Converters

  • Park, Chang Hee;Cho, Sung Ho;Jang, Jinhaeng;Pidaparthy, Syam Kumar;Ahn, Taeyoung;Choi, Byungcho
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • An average current mode control scheme that consistently offers good dynamic performance for LLC series resonant DC-to-DC converters irrespective of the changes in the operational conditions is presented in this paper. The proposed control scheme employs current feedback from the resonant tank circuit through an integrator-type compensation amplifier to improve the dynamic performance and enhance the noise immunity and reliability of the feedback controller. Design guidelines are provided for both current feedback and voltage feedback compensation. The performance of the new control scheme is demonstrated through an experimental 150 W converter operating with 340 V to 390 V input voltage to provide a 24 V output voltage.

The Analysis and Compensation of DC to DC Converter with Current Mode Controller (전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구)

  • 김철진;김영태;송요창
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.