• 제목/요약/키워드: Comparison of efficiency

검색결과 3,222건 처리시간 0.028초

높은 도착효율을 가지는 회전형 정전 도장기기의 개발 (Development of the Rotary Electrostatic Painting Equipment with High Transfer Efficiency)

  • 이찬;차상원;호광일
    • 한국유체기계학회 논문집
    • /
    • 제7권6호
    • /
    • pp.7-14
    • /
    • 2004
  • A new electrostatic rotary atomizing painting equipment using air turbine was developed for high transfer efficiency. Based on the overall design requirements of painting equipment, basic design specifications of the equipment parts such as air turbine and atomizing disk ate defined from the present conceptual design model. Air turbine is designed with the section profile of NACA airfoil, and its internal flow field is analyzed by commercial CFD code. Atomizing disk is designed to achieve the ligament type spray of paint with the use of visualization technique. Various experiments and tests are conducted to investigate the spray and the transfer characteristics of newly-designed painting equipment, and the measurement results are compared with the those of conventional painting equipments. The comparison results show the present painting equipment is superior to the conventional ones in the aspects of transfer efficiency and coating surface characteristics.

승용차 대시부의 구조 방사 효율 저감 방법 제안 (A Suggestion of Method to reduce the Radiation Efficiency of Dash Panel of a Passenger Car)

  • Kim, Young-Ki;Kang, Yeon-June;Ahn, Ok-Kyun;Ki, Ji-Hyeon;Park, Yoon-Bong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.332.1-332
    • /
    • 2002
  • The study was performed as reduction method using finite and boundary element analysis on structure-borne noise radiated by dash panel of a real car. The radiation efficiency is used to estimate sound noise of dash panel. Curvature and edges of dash panel have effect on radiation efficiency. The simulation results of dash panel was ensured by comparison between experimental results and simulation results of a simple rectangular plate. (omitted)

  • PDF

반응 표면법을 이용한 Multi-layer 매입형 영구자석 동기정동기의 효율 향상 (Improvement of efficiency in Multi-layer IPMSM using Response Surface Methodology)

  • 방량;권순오;이상호;장붕;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.777-778
    • /
    • 2006
  • This paper deals with the optimum rotor design approach about the multi-layer design of the buried magnets in an Interior Permanent Magnet Synchronous Motor (IPMSM), on the efficiency improvement by using Response Surface Methodology (RSM). In the multi-layer design of the prototype 15kw IPMSM, the constant amount of buried PM is split from the single-layer into double-layer design for improving the efficiency characteristics. The optimum double-layer rotor structure is built with the help of RSM analysis. The improvement of IPMSM efficiency is verified by the Finite Element Method (FEM) results comparison with the prototype single-layer IPMSM.

  • PDF

접선유입식과 축상유입식 사이클론의 집진효율 비교 (Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

동기 정류기를 이용한 위상 변위 제어 클램프 모드 포워드 다중 공진형 컨버터 (Phase Shift Controlled GM ZVS-MRC with Synchronous Rectifier)

  • 송종화;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2016-2019
    • /
    • 1997
  • To solve the low efficiency problem of low-voltage power supplies, it has been studied to replace the schottky barrier diode with the MOSFET synchronous rectifier. In this paper, Phase Shift-Controlled Clamp Mode Zero Voltage Switching-Multi Resonant Converter with Synchronous Rectifier (PSC CM ZVS-MRC with SR) is presented to achieve high efficiency in low-voltage power supplies. The characteristics analysis of synchronous rectifier is established by using the MOSFET equivalent circuit and efficiency comparison is established between the Synchronous Rectifier and the schottky barrier diode. To verify the validity of the analysis, 33W(3.3V, 10A) PSC CM ZVS-MRC with self-driven synchronous rectifier at switching frequency of 1MHz is designed and tested. And it is confirmed that the experimental results are well consistent with the theoretical results. The maximum efficiency of the converter is 83.4% at full load, which is 3.3% higher than conventional schottky diode rectification.

  • PDF

F-O-O-F 인젝터의 혼합 특성 (The mixing characteristics of Unlike Split Triplet(F-O-O-F) Impinging-Jet Injector Elements)

  • 임병직;정기훈;윤영빈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.283-286
    • /
    • 2002
  • The mixing of fuel and oxidizer and each mass distribution of unlike split triplet(F-O-O-F) injector for liquid rocket which are known to affect the combustion efficiency significantly, has been investigated using PLLIF technique. Experiment is conducted to investigate the effect of mixture ratio(MiR), momentum ratio(MoR) and impinging angle on mixing efficiency. The mixing efficiency, which is introduced by Rupe, gives the global chracteristic of spray mixing. Experiment far comparison with triplet injector(F-O-F), which has same momentum ratio and impinging angle with split triplet injector is conducted.

  • PDF

변압기용 고효율 차음판의 진동 및 소음 비교 (Comparison of vibration and noise characteristic of high efficiency Insulation Panel for Transformer)

  • 정재환;장용석;임동수;김진;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.1005-1009
    • /
    • 2008
  • The high efficiency insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in side of city is appeared a lost of problem by increasing to conserve the living environment. Therefor in this paper, first the vibration and noise characteristic of existing insulation panel is analyzed according to attached material, cork and sponge-type. Second the insulation of sound performance is compared between the existing insulation panel. And high efficiency insulation panel that is proposal in this paper.

  • PDF

A comparison of the traditional scoring system with the efficiency measuring system for evaluating the TQM activities

  • Yoo, Han-Joo;Lee, Jeong-Dong
    • 품질경영학회지
    • /
    • 제27권2호
    • /
    • pp.47-56
    • /
    • 1999
  • In this paper, we analyzed two methodologies to evaluate the total quality management activities comparatively. One of them is the traditional scoring system (TSS) by analytic hierarchy process (AHP) and the other is the efficiency measuring system (EMS) by data envelop analysis (DEA). It is demonstrated that the index by TSS and the efficiency index by EMS are not correlated. Also, the efficiency index by EMS in terms of company characteristics such as the size of company and ISO certifications is different from the index by TSS. The result implies that to evaluate the quality activities by EMS is needed as a supplementary methodology.

  • PDF

자전거 거치대 잠금장치의 부하시 효율개선을 위한 구동모터성능비교에 관한 연구 (A Study on Driving Motor Performance Comparison for Load Efficiency Improvement of a Bicycle Locker System)

  • 한기수;원성홍
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.175-180
    • /
    • 2013
  • This paper presents the design and implementation of a Bicycle Locker System. Generally DC motor has been used to control a Bicycle Locker System, but DC motor system requires frequent maintenances and its power efficiency is comparatively poor especially under heavy load conditions. In order to improve this difficulties, this paper adopts BLDC motor for a Bicycle Locker System and its motor controller is developed. The performances of locker units are compared between DC motor unit and BLDC motor unit. The motor power consumptions between two motors are discussed. Test results verify that power efficiency of the suggested BLDC drive unit is considerably improved compared to the DC drive unit with load condition.

단상 유도전동기의 고정자 동손 최소화를 위한 설계 방법 (Design Methodology for Minimal Stator Copper Loss in A Single-phase Induction Motor)

  • 백수황;김병택;권병일
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1536-1545
    • /
    • 2008
  • In this paper, we research a new method for efficiency improvement of a single-phase Induction motor by minimization of the stator loss. To make this, we perform winding design which is based on balanced and quasi-balanced operation condition. It gives efficiency improvement greatly but poor starting torque simultaneously. To obtain the best efficiency improvement maintaining the maximum and starting torque, the optimal winding specification and rotor dimension is determined with variation of secondary resistance, running capacitor and turn ratio. Finally, this paper gives the comparison between the simulation results and experimental results.