• Title/Summary/Keyword: Compared and analyzed

검색결과 21,331건 처리시간 0.05초

여성 노인의 좌관맥상(左關脈象)에 대한 실험적 연구 (Experimentational Study on the Pulsation of the Elder Women)

  • 강희정;김경철
    • 동의생리병리학회지
    • /
    • 제20권1호
    • /
    • pp.83-87
    • /
    • 2006
  • The oriental medicine is necessary to the development of oriental medicine diagnosis, to satisfy the Senior-Friendly. We experiment on the elderly women in 3-D mac, and carry into effect the comparative-study on the youth's pulsation. The elder pulsation's division factor are analyzed press power, w/t, h5/h1 , dispersion of period. In the press power, the elder pulsation is shallow compared with the youth's pulsation. In the w/t (pressurization time / pulsation cycle), the elder pulsation is longer compared with the youth's pulsation, In the h5/h1 (dicrotic / main peak), the elder pulsation is small compared with the youth's pulsation. In the range of dispersion of period, the elder pulsation is narrow-changed compared with the youth's pulsation. Therefore the elder pulsation is characterized by the deficiency of flexibility and injection power.

패리티 검사비트를 이용한 새로운 오류정정 기술 (Error Correcting Technique with the Use of a Parity Check Bit)

  • 현종식;한영열
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 1997년도 추계학술대회 발표논문집:21세기를 향한 정보통신 기술의 전망
    • /
    • pp.137-146
    • /
    • 1997
  • The simplest bit error detection scheme is to append a parity bit to the end of a bit sequence. In this paper an error correction technique with the use of a parity bit is proposed, and the performance of the proposed system is analyzed. The error probability of the proposed system is compared with the output of computer simulation of the proposed system. It is also compared with the error probability of error at BPSK system, and the signal-to-noise ratio gain is showed.

  • PDF

데이터 수집 장치를 이용한 유도탄 구동장치 점검 제안 (Proposal for guided missile actuator device inspection using data acquisition device)

  • 정의재;오택근;이정민;유필중
    • 한국항행학회논문지
    • /
    • 제27권4호
    • /
    • pp.423-428
    • /
    • 2023
  • 유도탄 구동장치는 구동장치 날개 펼침 시간과 위치가 유도탄의 초기 기동에 매우 중요한 요소가 되며, 유도탄 구동장치 점검은 구동 동작 수집 데이터 획득 정확성과 실시간성이 보장되어야 한다. 본 연구에서는 기존 구동장치 점검 설계 및 구현방식과 데이터 수집장치 구동장치의 설계 구현방식 차이를 비교하고, 데이터 수집량, 실시간 데이터 수집 성능 차이를 획득 후 비교하였으며, 시험을 통해 나타난 데이터를 그래프로 변환한다. 획득된 데이터 구동장치 파형을 비교 분석하고, 분석된 데이터를 기반으로 기존 구동장치 점검과 데이터 수집장치 점검 중 실시간 응답 속도와 안정성이 보장된 데이터 수집장치 점검구성을 제안한다.

기능적 조음음운장애아동의 치조 마찰음 왜곡의 음향음성학적 특성 (Acoustic-phonetic characteristics of fricatives distortion in functional articulation disorders)

  • 양민교;최예린;김은연;유현지
    • 말소리와 음성과학
    • /
    • 제10권4호
    • /
    • pp.127-134
    • /
    • 2018
  • This study aims to explain the difficulties children with articulation and phonological disorders have in producing alveolar fricative sounds. The study will perform a comparative analysis revealing how ordinary children produce alveolar fricative sounds through five different acoustic variables, and consequently identifying objective differences, compared to children with articulation and phonological disorders. Therefore, this study compared and analyzed the differences between 10 children with articulation and phonological disorders and 10 ordinary children according to a phonation type of alveolar fricative sounds (/s/ and /$s^*$), a type of vowel (/i/, /ε/, /u/, /o/, /ɯ/, /ʌ/, /ɑ/), and a structure of syllables (CV, VCV) through acoustic variables including a central moment, skewness, kurtosis, a center of gravity and variance. That is, children with articulation and phonological disorders, when compared to ordinary children, have difficulties with concentrating an agile and momentary friction with strength when articulating alveolar fricative sounds, which uses strong energy and accompany tension. Furthermore, the values of alveolar fricative sounds of children with articulation and phonological disorders appeared to spread evenly over the average range, which means that the range of overall the standard deviation values for children with functional phonological disorders is wider than that of ordinary children. For a future study, if the mispronounced sounds relating to omission, substitution, and addition can be compared and analyzed for various target groups, it could be used effectively to help children with functional phonological disorders.

Ultrasound-guided needle decompression and steroid injection for calcific tendinitis of the shoulder: risk factors for repeat procedures and outcome analysis

  • Kim, Su Cheol;Lee, Sang Min;Park, Gun Tae;Jang, Min Chang;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.55-65
    • /
    • 2021
  • Background: Although ultrasound-guided needle decompression (US-GND) can treat calcific tendinitis of the shoulder effectively, repeat procedures might be required for unresolved symptoms. We evaluated the overall clinical outcomes of US-GND with subacromial steroid injection and the final results and factors predisposing toward repeat procedures. Methods: Ninety-eight patients who underwent US-GND for calcific tendinitis of the supraspinatus/infraspinatus were analyzed between March 2017 and December 2018. The clinical outcomes (pain visual analog scale, functional visual analog scale [FVAS], and American Shoulder and Elbow Surgeons [ASES] score) and final subjective satisfaction were compared between groups A (single US-GND) and B (repeat US-GND). The factors predisposing toward repeated US-GNDs were analyzed. Results: We found that 59.3% (58/98) of patient ASES scores were ≥80, and 73.5% of patients (72/98) were satisfied with the outcome. Group B (n=14) demonstrated a significantly higher rate of dominant-arm involvement compared to group A (78.6% vs. 48.8%, p=0.046). However, initial calcification size, shape, number, density, subscapularis involvement, lavage, and procedure time did not differ significantly between the groups. Group B showed poorer final FVAS (7 [interquartile range, 6-8] vs. 8 [interquartile range, 7-9], p=0.036) and subjective satisfaction compared to group A (satisfied: 5 [35.7%] vs. 67 [79.8%], p<0.001]. Conclusions: US-GND with subacromial steroid injection is a viable treatment option for calcific tendinitis of the shoulder. Dominant-arm involvement was the only independent factor for repeated US-GND. Final outcome of repeated US-GND for unimproved patients was promising; however, these outcomes were poor compared to those of the patients who improved after the first procedure.

입력지진 세기에 따른 콘크리트 주탑 케이블교량의 부재별 거도 특성 연구 (Behavior of Cable Suppored Bridges with RC Pylon Under Varying Seismicities)

  • 임영근;정혁창;김익현;이종석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.349-352
    • /
    • 2006
  • According to current bridge design code cable supported bridges are designed generally against 1000-year-return-period earthquake. Considering its importance, however, it may be desirable to design against 2400-year-return-period earthquake. But the seismic behavior of cable supported bridges under higher seismicity is not investigated fully. In this study, several cable supported bridges were analyzed under higher seismicity and then the response forces in prime members were compared with those analyzed under current design earthquake.

  • PDF

간접구 시술이 골격근 Adiposity 유발 쥐의 근육조직에 미치는 영향 (Effects of Indirect Moxibustion on Skeletal Muscles in Mouse Model of Skeletal Muscle Adiposity)

  • 이기수;홍권의
    • Journal of Acupuncture Research
    • /
    • 제31권1호
    • /
    • pp.7-21
    • /
    • 2014
  • Objectives : To observe the regenerative effects of indirect moxibustion, a traditional Korean medical treatment on skeletal muscles using mouse model of skeletal muscle adiposity. Methods : Twenty seven ICR male mice were randomly assigned into Intact control(n=3), glycerol treatment together without moxibustion(n=12), and glycerol treatment together with moxibustion (n=12) groups. Mice of glycerol treatment groups were injected with 50 ${\mu}l$ DW(distilled water) containing 50 % of glycerol into the two tibialis anterior. After injection, moxibustion was applied at 'Shenshu'($BL_{23}$) and 'Zusanli'($ST_{36}$) acupoints three times per each session, every days for twelve days(total 12 treatments). Phospho-Erk1/2, Myostatin protein levels were analyzed by western blotting and immunofluo-rescence staining techniques for tissues of the tibialis anterior muscle. Smad, phospho-Smad were analyzed by immunofluorescence staining. Results : 1. Histological analysis of sections from injected TA muscles showed that glycerol induced rapidly muscle necrosis, with a maximum at day 3. 6 days and 9 days after injection, muscle was regenerating. 2. According to western blotting and immunofluorescence staining, phospho-Erk1/2 protein signals in glycerol treatment with moxibustion group were stronger compared to Intact and glycerol treatment without moxibustion group. 3. According to western blotting and immunofluorescence staining, myostatin protein signals in glycerol treatment without moxibustion group were stronger compared to Intact and glycerol treatment with moxibustion group. 4. According to immunofluorescence staining, Smad protein signals in glycerol treatment without moxibustion group were stronger compared to Intact and glycerol treatment with moxibustion group. 5. According to immunofluorescence staining, phospho-Smad protein signals in glycerol treatment without moxibustion group were stronger compared to Intact and glycerol treatment with moxibustion group. Conclusions : These results confirm that indirect moxibustion of 'Shenshu'($BL_{23}$) and 'Zusanli'($ST_{36}$) influences muscle regeneration in mouse models of skeletal muscle adiposity. Further discussion, and the establishment of moxibustion mechanism will prompt clinical application of moxibustion.

Macronutrient Analysis of Human Milk according to Storage and Processing in Korean Mother

  • Kim, Min Hyung;Shim, Kyu Seok;Yi, Dae Yong;Lim, In Seok;Chae, Soo Ahn;Yun, Sin Weon;Lee, Na Mi;Kim, Su Yeong;Kim, Seung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권3호
    • /
    • pp.262-269
    • /
    • 2019
  • Purpose: As the importance of breastfeeding has been reinforced, human milk is often stored for practical reasons. Therefore, we evaluated optimal storage and processing methods for human milk from a nutritional standpoint. Methods: Human milk samples were collected between June 2017 and February 2018. Also, data about maternal information were collected. Human milk was analyzed for macronutrients and caloric content. The samples were subdivided into groups for nutrient analysis. The control group (fresh milk) was not stored or processed. The other groups (9 groups) consisted of samples analyzed based on different storage temperatures (room temperature, refrigerated, frozen), defrosting methods (bottle warmer, room temperature thawing, microwave oven), and storage period (1 week, 1 month, 2 months) and compared with the control group. Results: There was no statistically significant difference in the nutrient content of human milk among the collected samples. A significant change in the content of macronutrients in milk samples was observed under storage condition at different temperatures for 1 week with subsequent thawing with bottle warmer compared to fresh milk. Under storage at $-20^{\circ}C$ for 1 week with subsequent thawing with different defrosting methods, a significant change in the content of macronutrients in milk samples was observed compared to fresh milk. After storage at $-20^{\circ}C$ for different periods and thawing with a bottle warmer, a significant change in macronutrient content in milk samples was observed compared to fresh milk regardless of the storage period. Conclusion: Unlike previous guidelines, changes in macronutrient content in milk samples were observed regardless of the method of storing and thawing. Apparently, it is proposed that mothers should feed fresh human milk to their babies without storing.

전동화된 스피드 스프레이어의 블레이드 형상에 따른 송풍구 유동 특성 분석 (Analysis of the Flow Characteristics for the Blower According to the Blade Shape of the Electrified Speed Sprayer)

  • 오승훈;심재록;서현규
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.16-23
    • /
    • 2023
  • The objective of this numerical study is to investigate the effect of the shape and material of the blower blade for the electrified speed sprayer on the blowing performance. The shape of the blade was changed to the bonding angle, the number of blades, the width of the blade, and the blade length based on the existing model. In order to obtain the reliability of the numerical model, the analysis of the grid dependence was performed in the numerical analysis. The numerical analysis results were compared and analyzed in terms of the agricultural chemical penetration length characteristics, flow uniformity characteristics, and velocity distribution characteristics. Furthermore, the effect of material change on weight reduction and structural characteristics was also compared and analyzed. As a result of the analysis, it was found that the optimal condition was that the blade angle was 45°, the number of blades was 12, and the width was 115 mm, which was confirmed through a comparison of the inlet mass flow rate. As a result of the equivalent stress lower than the yield strength due to the material change from aluminum to steel compared to the existing steel, structural defects do not appear, and it is judged that the operation time compared to the battery capacity will be improved through the weight reduction of the blade.

선반 기어박스의 진동.소음 분석과 저감에 관한 연구 (A Study on Vibration and Noise Reduction of a Lathe Gear Box)

  • 박선균;최영휴;배병태;정택수;김청수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.552-558
    • /
    • 2001
  • When operating lathe gear box which is equipped with geared transmission, it sometimes generates loud noise and excessive vibrations. In order to identify their causes, in this study, torsional and lateral vibration characteristics including critical speeds of the gear transmission system are firstly analyzed using lumped parameter models. Natural frequencies and mode shapes of the gear box structure are also analyzed by using the modal test. Furthermore, measured vibration and noise signals during operations are analyzed and compared with theoretical analysis results. After all, it is concluded that the primary cause of the excessive noise and vibrations is the resonance between gear meshing frequency including its side bands, the frequencies of shaft bending and torsional vibrations, and the natural frequencies of the gear box structure. Consequently the noise and vibration levels are greatly reduced by avoiding resonance between the natural frequencies and gear meshing frequencies through the rearrangement of the gears on the transmission shaft without any gear ratio change.

  • PDF