• 제목/요약/키워드: Comparative calibration

검색결과 97건 처리시간 0.028초

A Comparative Analysis between Rigorous and Approximate Approaches for LiDAR System Calibration

  • Kersting, Ana Paula;Habib, Ayman
    • 한국측량학회지
    • /
    • 제30권6_2호
    • /
    • pp.593-605
    • /
    • 2012
  • LiDAR systems provide dense and accurate topographic information. A pre-requisite to achieving the potential accuracy of LiDAR is having a proper system calibration, which aims at estimating all the systematic errors in the system measurements and the mounting parameters relating the different components. This paper presents a rigorous and two approximate methods for LiDAR system calibration. The rigorous approach makes use of the LiDAR equation and the system raw measurements. The approximate approaches utilize simplified LiDAR equations using some assumptions, which allow for less strict requirements regarding the raw measurements. The first presented approximate method, denoted as quasi-rigorous, assumes that we are dealing with a vertical platform (i.e., small pitch and roll angles). This method requires time-tagged point cloud and trajectory position data. The second approximate method, denoted as simplified, assumes that we are dealing with parallel strips, vertical platform, and minor terrain elevation variations compared to the flying height above ground. Such method can be performed using the LiDAR point cloud only. Experimental results using a real dataset, whose characteristics deviate to some extent from the utilized assumptions in the approximate methods, are presented to provide a comparative analysis of the outcome from the introduced methods.

질량분석기형 누출검출기를 이용한 헬륨투과형 표준 누출 비교 교정 장치 개발 (Development of Comparative Calibration System for Helium Leak Standard by Using Mass Spectrometer Type Leak Detector)

  • 홍승수;임인태;김진태;신용현
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.151-156
    • /
    • 2008
  • 반도체나 디스플레이 제조 등 진공공정의 리크검출에는 질량분석기형(mass spectrometer type) 헬륨 리크검출기(leak detector)가 사용되고 있다. 이 기기를 이용해서 안정된 측정값을 얻기 위해서는 장치 내부에 내장된 투과형(permeation type) 표준리크(standard leak)를 이용해서 자주 spectrometer를 교정해야 한다. 본 연구에서 질량분석기형 리크검출기의 비교교정 장치의 개발과 교정방법에 대한 연구결과를 언급하였다. 따라서 이 기술을 이용하면 질량분석기형 리크검출기를 구비하고 있는 현장에서도 표준리크의 비교교정이 가능하게 된다.

GC의 주입방식 차에 따른 고농도 악취황 성분의 검량오차 연구 : 주입부피의 고정방식 대비 주입농도의 고정방식 간 비교연구 (The Selection of Sample Injection Modes and Its Effect on the Calibration Bias in S Gas Detection by Gas Chromatography)

  • 김기현;최여진
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.269-274
    • /
    • 2005
  • In this work, analytical bias arising from the gas chromatographic determination of sulfur compounds was evaluated by the application of direct loop injection method to the GC/PFPD detection of four sulfur compounds including H$_{2}$S, CH$_{3}$SH, DMS, and DMDS. For the proper evaluation of analytical uncertainties involved in GC calibration, we employed two comparative techniques of calibration at fxed concentration injection (CFCI) vs calibration at fixed volume injection (CFVI) method. The results of our study indicate that CFCI method exhibits very poor sensitivity due to the matrix effect with varying injection volumes. On the other hand, as CFVI method overcomes such limitation, it can be used to obtain very accurate quantification of S compounds at their high concentration levels above a few to a few tens ppb.

Examination of Cross-calibration Between OSMI and SeaWiFS: Comparison of Ocean Color Products

  • Lee, Sun-Gu;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.209-215
    • /
    • 2002
  • Much effort has been made in the radiometric calibration of the ocean scanning multispectral imager (OSMI) since after the successful launch of KOMPSAT-1 in 1999. A series of calibration coefficients for OSMI detectors were obtained in collaboration with the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary (SIMBIOS) project office. In this study, we compare the OSMI level-2 products (e.g., chlorophyll-a concentration) calculated from the NASA cross-calibration coefficients with the SeaWiFS counterparts. Sample study areas are some of diagonostic data sites recommended by the SIMBIOS working group. We will present the preliminary results of this comparative study.

  • PDF

단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구 (Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D)

  • 서정범;김동현;이정범
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

5공과 7공 프로브를 이용한 터빈 캐스케이드의 이차유동 측정 결과 비교연구 (Comparative Study on the Secondary Flow Measurement in a Turbine Cascade Using 5-hole and 7-hole Probes)

  • 노영철;이용진;박정신;김학봉;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.5-12
    • /
    • 2010
  • Comparative study on the flow measurement by 5-hole and 7-hole probes was conducted in a linear cascade with tip clearances of 2.3%, 3.1%, and 4.4% of the blade span. Calibration range of the 5-hole and the 7-hole probes were ${\pm}25$ and ${\pm}50$ degrees, respectively. Results show that the secondary flow and total pressure loss measured by the 5e-hole and 7-hole probes were similar at small tip clearance cases. However, at the tip clearance of 3.1% and 4.4% of the blade span cases, flow angles exceeding the calibration range of the 5-hole probe were observed. Because of the wider calibration range, larger flow angle by strong leakage vortex could be measured by the 7-hole probe.

적외선 열화상 카메라용 캘리브레이션 타겟 개발 (Development of Calibration Target for Infrared Thermal Imaging Camera)

  • 김수언;최만용;박정학;신광용;이의철
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.248-253
    • /
    • 2014
  • 카메라 영상 캘리브레이션은 머신비전과 같은 비전검사기술분야에서 영상으로부터 기하학적 정보를 정확하게 추출하고자 할 때 정확성을 높이는데 필요한 매우 중요한 과정이다. 그러나 기존에 가시광 카메라에 사용되던 캘리브레이션 타겟은 중적외선, 원적외선 열화상 카메라에 적용하기 어렵다. 최근에 적외선 열화상카메라를 이용한 결함측정기술이 많이 사용되면서 적용할 수 있는 캘리브레이션 타겟 개발이 요구되고 있다. 따라서 본고에서는 유한요소 열전달 해석을 이용하여 가시광 카메라와 적외선 열화상카메라 모두에 적용 가능한 캘리브레이션 타겟을 제안하였다. 개발된 캘리브레이션 타겟을 열화상카메라와 가시광 카메라로 촬영하여 비교실험 하였으며, 실험결과 제안된 캘리브레이션 타겟의 효율성을 보여준다.

750 kW급 직결형 국산화 풍력발전시스템의 기계적 보정 (Mechanical Calibration of 750 kW Gearless Type Wind Turbine(KBP-750D))

  • 길계환;최효진;김영찬;정진화;조주석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2008
  • 포항공과대학교의 포항풍력에너지연구소(PoWER Center)가 개발에 참여했던 750 kW급 직결형 국산화 풍력발전 시스템의 상용화를 추진하기 위한 출력성능 및 하중 측정을 통한 실증연구가 대관령의 풍력실증단지에서 수행되었다. IEC 61400-13의 규격을 기준으로 수행된 하중 측정의 일환으로 스트레인 게이지의 기계적 하중에 대한 외부 하중부가에 의한 기계적 보정이 추진되었다. 기계적 보정의 수행 중 일부스트레인 게이지가 단락되는 사고가 발생하였으나 비교보정을 통하여 기계적 보정작업을 완수할 수 있었다. 본 논문에서는 외부 하중부가에 의한 기계적 하중의 보정절차를 소개하고, 수행된 기계적 보정시험 과정에 대해 상세히 설명하며 기계적 보정의 결과를 보고한다.

  • PDF

A comparative analysis of structural damage detection techniques by wavelet, kurtosis and pseudofractal methods

  • Pakrashi, Vikram;O'Connor, Alan;Basu, Biswajit
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.489-500
    • /
    • 2009
  • The aim of this paper is to compare wavelet, kurtosis and pseudofractal based techniques for structural health monitoring in the presence of measurement noise. A detailed comparison and assessment of these techniques have been carried out in this paper through numerical experiments for the calibration of damage extent of a simply supported beam with an open crack serving as an illustrative example. The numerical experiments are deemed critical due to limited amount of experimental data available in the field of singularity based detection of damage. A continuous detectibility map has been proposed for comparing various techniques qualitatively. Efficiency surfaces have been constructed for wavelet, kurtosis and pseudofractal based calibration of damage extent as a function of damage location and measurement noise level. Levels of noise have been identified for each technique where a sudden drop of calibration efficiency is observed marking the onset of damage masking regime by measurement noise.