• 제목/요약/키워드: Compaction control

검색결과 166건 처리시간 0.022초

CFRD 차부벽콘크리트의 수성수축균열 제어특성에 관한 실험적 연구 (An Experimental Study on the Control Property of PlasticShrinkage Crack for CFRD Face Slab Concrere)

  • 김완영;최세진;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.118-121
    • /
    • 2000
  • CFRD (Concrete Faced Rockfill Dam) face slab concrete has a much capability to occur crack due to drying shrinkage, hydration heat and bas compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. This is an experimental study to analyze the Control Property of Plastic Shrinkage Crack for CFRD face slab concrete. For this purpose, it was investigated and analyzed the engineering properties of plain concrete and using admixtures (polypropylene fiber, fly-ash) according to test result As the result, it was found that crack width and area of concrete using admixtures less than of plain concrete.

  • PDF

Field Enhanced Rapid Thermal Process for Low Temperature Poly-Si TFTs Fabrications

  • Kim, Hyoung-June;Shin, Dong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.665-667
    • /
    • 2005
  • VIATRON TECHNOLOGIES has developed FE-RTP system that enables LTPS LCD and AMOLED manufacturers to produce poly-Si films at low cost, high throughput, and high yield. The system employs sequential heat treatment methods using temperature control and rapid thermal processor modules. The temperature control modules provide exceptionally uniform heating and cooling of the glass substrates to within ${\pm}2^a\;C$. The rapid thermal process that combines heating with field induction accelerates the treatment rates. The new FE-RTP system can process $730{\times}920mm$ glass substrates as thin as 0.4 mm. The uniform nature of poly-Si films produced by FE-RTP resulted in AMOLED panels with no laser-Muras. Furthermore, FE-RTP system also showed superior performances in other heat treatment processes involved in poly-Si TFT fabrications, such as dopant activation, gate oxide densification, hydrogenation, and pre-compaction.

  • PDF

Effects of interface angles on properties of rock-cemented coal gangue-fly ash backfill bi-materials

  • Yin, Da W.;Chen, Shao J.;Sun, Xi Z.;Jiang, Ning
    • Geomechanics and Engineering
    • /
    • 제24권1호
    • /
    • pp.81-89
    • /
    • 2021
  • Uniaxial compression tests were conducted on sandstone-CGFB composite samples with different interface angles, and their strength, acoustic emission (AE), and failure characteristics were investigated. Three macro-failure patterns were identified: the splitting failure accompanied by local spalling failure in CGFB (Type-I), the mixed failure with small sliding failure along with the interface and Type-I failure (Type-II), and the sliding failure along with the interface (Type-III). With an increase of interface angle β measured horizontally, the macro-failure pattern changed from Type-I to Type-II, and then to Type-III, and the uniaxial compressive strength and elastic modulus generally decreased. Due to the small sliding failure along with the interface in the composite sample with β of 45°, AE events underwent fluctuations in peak values at the later post-peak failure stage. The composite samples with β of 60° occurred Type-III failure before the completion of initial compaction stage, and the post-peak stress-time curve initially exhibited a slow decrease, followed by a steep linear drop with peaks in AE events.

사용재료의 품질변동이 고유동콘크리트의 특성에 미치는 영향-인천 LNG 인수기지 #213,214-TK를 중심으로- (An Effect on the Properties of High Flowing Concrete by Materials Variations-Focused on Inchon LNG Receiving Terminal #213,214 Tanks-)

  • 권영호;김무한
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.99-107
    • /
    • 2000
  • This research investigates experimentally an effect on the properties of the high flowing concrete to be poured in the under-ground slurry wall of Inchon LNG receiving terminal(#213,214-TK) according to variations of concrete materials. Variables for sensitivity test were selected items as followings. 1) Concrete temperature (3cases), 2) Unit water (5cases), 3) Fineness modulus of fine aggregate (5cases), 4) Particle size of lime stone powder (3cases), 5) Replacement ratio of blast-furnace slag (4cases) and 6) Addition ratio of high range water reducing agent (5cases). And fresh conditions of the super flowing concrete should be satisfied with required range including slump flow(65$\pm$5cm), 50cm reaching time of flow(4~10sec), V-lot flowing time(10~ 20sec), U-box height(min. 300mm) and air content(4$\pm$1%). As results for sensitivity test, considered flow-ability, self-compaction and segregation resistance of the high flowing concrete, material variations and conditions of fresh concrete should be satisfied with the range as follwings. 1) Concrete temperature are 10~2$0^{\circ}C$(below 3$0^{\circ}C$), 2) Surface moisture of fine aggregate is within $\pm$ 0.6%, 3) Fineness modulus of fine aggregate is 2.6$\pm$0.2, 4)Replacement ratio of blast-furnace slag is 45~50% and 5) Addition ratio of high range water reducing agent is within 1%. Based on the specification for quality control, we successfully finished concrete pouring on the under-ground slurry wall having 75,000㎥(#213,214-TK) and accumulated real date in site.

고성토 암버력 동다짐 지반에 시공된 PHC 말뚝의 거동특성 사례연구 (A Case Study of PHC Pile Behavior Characteristics on Dynamic Compacted High Rock Embankment)

  • 유남재;윤동균;배경태;김형석;이달호;박용만
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.519-526
    • /
    • 2010
  • The construction site for $\bigcirc\bigcirc$ transformer substation was located at a mountain valley. In order to prepare the site, the valley was first filled with crushed rock debris up to 63m. Since the main concern of this project is to minimize differential settlement of the foundation of transformer facilities, dynamic compaction was performed every 7m followed by reinforcement with EMP(Ez-Mud Piling). The EMP is one of bored piling methods, in which a hole is bored by means of air percussion and maintain by injecting Ez-Mud. Then a PHC pile (Pretensioned spun High strength Concrete pile) is embedded and finalized with a hammer. In this study, bearing capacities and long term behavior of a pile installed by EMP were investigated. To achieve these objectives, a series of tests such as static and dynamic load tests were conducted. In addition, a construction quality control standard was proposed based on the test results.

  • PDF

궤도노반 강성차이를 고려한 동평판재하시험(LWDT) 동탄성계수 산정공식 수정계수 (Correction Factors for Modulus Calculation Equation used in Light Weight Deflectometer Considering Track Foundation)

  • 최찬용;이진욱;임유진;조호진
    • 한국철도학회논문집
    • /
    • 제18권1호
    • /
    • pp.53-62
    • /
    • 2015
  • 동평판재하시험기(LWDT)는 궤도노반 등의 다짐강성 측정을 위하여 개발된 시험기이며 낙하추를 자유낙하시킬 때 가속도계를 이용하여 다짐표면의 처짐량을 측정, 반무한 탄성체로 가정된 노반의 동탄성계수를 결정한다. 본 연구에서는 LWDT시험기의 구성과 구동 메커니즘 및 동탄성계수 추출공식의 유효성을 상세히 분석하였다. 특히, 2층구조 노반 위에서 LWDT 시험시 상부층의 강성평가 유효깊이를 유한요소해석으로부터 결정하였다. 또한, LWDT 시험시 노반의 강성 차이를 고려하여 사용할 수 있는 동탄성계수 추출공식 수정계수를 제시하였다.

Flat TDR 시스템을 이용한 흙의 함수비와 건조단위중량 측정 (Water Content and Dry Density Measurement of Soil Using Flat TDR System)

  • 김완민;김대현;서혁
    • 한국지반공학회논문집
    • /
    • 제33권11호
    • /
    • pp.5-19
    • /
    • 2017
  • 본 연구는 전통적인 다짐관리방법의 문제점을 보완하고자 TDR(Time Domain Reflectometry)을 이용하여 지반의 함수비와 건조단위중량을 측정하는 연구를 수행하였다. 개발된 Flat TDR 시스템의 측정값을 검증하기 위해 여섯 가지 시료를 대상으로 실내실험을 수행하였다. 또한 실내실험을 바탕으로 현장시험을 수행하여 현장 적용성을 검토하였고, 신뢰성을 확보하기 위해 Purdue TDR 시스템과 비교실험을 수행하여 정밀도를 확인하였다. 또한 유한요소해석을 수행하여 Flat 프로브의 영향범위를 확인하였다. 그 결과 약 10cm의 영향범위를 확인하였고, 실내실험결과 함수비는 평균적으로 약 0.4%의 오차를 보이며, 건조단위중량의 경우 약 1.6%의 오차를 보였다. 현장시험의 경우 함수비는 0.8%, 건조단위중량의 경우 2.5%의 오차를 보였다. 실험 결과를 통하여 Flat TDR 시스템의 측정값은 기존의 TDR 시스템보다 정확한 값을 도출하는 것을 확인할 수 있었다.

다당류 친환경 지반개량재를 이용한 지반강도 증대 효과 (Effects of Ground Strength Increase using Polysaccharide Environmentally Friendly Soil Stabilizer)

  • 김선태;도종남;조현수;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제12권11호
    • /
    • pp.13-21
    • /
    • 2011
  • 하천의 기본기능인 치수, 이수, 환경 및 문화 등을 되살리기 위한 국가적 사업인 4대강 국가하천 정비사업은 홍수에 안전한 문화 및 생태가 살아있는 친환경 하천 공간을 정비하기 위한 것으로 건설재료의 친환경성이 강조되고 있다. 본 연구에서는 다당류 친환경 개량재인 콘알파를 활용한 토양 및 시멘트 혼화제를 개발하여 다짐시험, 투수시험 및 일축압축강도시험을 통하여 친환경 하천 공간을 위한 건설재료로의 적합성을 평가하고자 하였다. 일축압축시험의 결과로는 다당류 지반개량재가 강도 증진에 큰 영향을 끼치지 않음을 알 수 있다. 이에 대한 원인을 분석한 결과, 일반적으로 자연 상태에서 토사에 서식하고 있는 각종 균들이 본 연구에서 정확한 배합비를 얻기 위해 건조로에서 고온으로 건조를 시키는 과정에서 활동성이 극 저하되어 강도증진 효과에 반영되지 않은 것으로 나타났다. 향후, 다당류 친환경 지반개량재와 관련된 시험에서는 각 시료를 자연상태에서 함수비를 측정하여 적정함 수비로 다진 뒤, 다당류 지반개량재를 혼합하여 공학적 시험을 실시하는 것이 바람직할 것으로 사료된다.

플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향 (Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique)

  • 소호영;이영미;김광근;김기옥;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.439-445
    • /
    • 2004
  • Continuous Wave 가압법으로 근관충전시 플러거 삽입 깊이에 따른 근관실러의 치근단 정출을 평가하고자 직선형의 단근관 및 15번 크기의 치근단공을 가지는 발거된 40개의 치아에서 0.06 경사도 40번 크기가 되게 니켈-티타늄 전동화일인 $ProFile^{\circledR}$로 근관을 형성하고 플러거 삽입깊이를 근단 3, 5 또는 7 mm로 하여 System $B^{TM}$를 이용한 Continuous Wave 가압법 및 측방가압법으로 근관을 충전하였다. 치근단으로 정출된 근관실러의 무게를 측정하여 일원변량분석법과 Duncan's Multiple Range Test로 통계분석하였다. 플러거 삽입깊이 3 mm 또는 5 mm의 Continuous Wave 가압 충전군은 삽입깊이 7 mm 가압충전 군 및 측방가압 충전군에 비해 유의하게 많은 근관실러의 치근단 정출을 나타내었다 (p < 0.05). 그러나 플러거 삽입깊이 3 mm군과 5 mm군 사이 및 플러거 삽입깊이 7 mm Continuous Wave 가압군과 측방가압 군 사이에는 유의한 차이가 나타나지 않았다 (p > 0.05). 본 연구의 결과로 보아 Continuous Wave 가압법으로 근관충전시에는 플러거 삽입깊이가 깊을수록 근관실러의 치근단 정출이 많음을 알 수 있다.

P/M법과 유도가열법을 이용한 A1 Foam 재료의 기공제어 (Control of Cell Morphology of Al Foams fabricated by P/M Method and Induction Heating)

  • 윤성원;이승후;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2001
  • Aluminium foams, having a closed cell structure, fabricated by applying the powder compact method and an induction heating were studied. The powdered A6061 mixed with the powdered titanium hydride as a foaming agent was hot pressed into a foamable precursor. The resulting precursor was foamed by induction heating up to desired temperature. The effects of the titanium hydride content ($0.3{\~}1.5 wt.\%$), pressing pressure of the foamable precursor material (50-150kN), the forming temperature ($610{\~}690^{\circ}C$) and heating rate during foaming on the expansion behavior of the foam were investigated.

  • PDF