• Title/Summary/Keyword: Communication module

Search Result 2,080, Processing Time 0.029 seconds

A Study on the design of operations system for managing the mobile communication network (이동통신망 관리용 운용시스템 설계에 관한 연구)

  • 하기종
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.2
    • /
    • pp.71-79
    • /
    • 1997
  • In this paper, operations system was designed for the centralization of data processing of various state information from the facilities of mobile communication network. And the system performance experimental system module was measured and analyzed from the designed experimental system module. The configuration of system design was presented with the centralized type to monite and control the facilities of mobile communication network in the central office. The communication process design of the internal system was implemented with the resource of message queue having a excellent transmission ability for processing of a great quantity of information in the inter-process communication among communication resources of UNIX system. The process with a server function from the internal communication processes was constructed with a single server or a double server according to the quantity of operations and implemented with the policy of the presented server. And then, we have measured performance elements in accordance with the change of input parameters from the designed experimental module : response time, waiting time, buffer length, the maximum quantity existing in message queue. And from these results, we have compared and analyzed the system state each server algorithm according to performance variations.

  • PDF

Non linearity Distortion Cancellation Module Design for Thermal Noise Compensation (열잡음 보상을 위한 비선형 왜곡제거 모듈 설계)

  • HwangBo, Chang;Ko, Young-Eun;Bang, Sung-Il
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.27-30
    • /
    • 2005
  • In this paper, we designed and manufactured the distortion cancellation module which is able to compensate thermal-noise distortion by software The distortion cancellation algorithm not only bring forth system non-linear distortion by input level but also bring compensate component of distortion by thermal to get rid off distortion from now on. After TMS320C6711 DSP to recognize our algorithm, we manufactured the module for every kinds of system To evaluate efficiency of the distortion cancellation module, we designed and manufactured communication system. By measured result, if system output power is -3dBm equally, 12dB of ACLR has improved in 1MHz away from a center frequency, and also gain has increased up to 0.5dB.

  • PDF

A Study on Implementation of Zigbee Module based on CC520 (CC2520 기반의 지그비 모듈 구현에 대한 연구)

  • Moon, Yong-Seon;Bae, Young-Chul;Roh, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.664-671
    • /
    • 2010
  • In this paper, we developed a Zigbee module based on CC2520 which is possible to construct the mesh network and also support to Zigbee Pro standard as a preceding research of autonomous moving of mobile robot using Zigbee. After manufacturing the Zigbee module, we selected antenna to fit Zigbee wireless frequency band using network analyze as means performance improvement. We also carry out an impedance matching of Zigbee module, extend the possible distance of two-way wireless communication and ensure the safety of communication.

Remote Fault Diagnosis and Maintenance System for NC Machine Tools (공작기계용 원격 고장진단 및 보수 시스템)

  • 신동수;현웅근;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • Remote fault diagnosis and maintenance system using general telecommunication network is necessary for an effective fault diagnosis and higher productivity of NC machine tools. In order to monitor machine tool condition and diagnose alarm states due to electrical and mechanical faults, a remote data communication system for monitoring of NC machine fault diagnosis and status is developed. The developed system consists of (1) remote communication module among NC's and host PC using PSTN. (2) 8 channels analog data sensing module, (3) digital I/O module for control or NC machine, (4) communication module between NC machine and remote data communication system via RS-232C, and (5) software man-machine interface. Diagnostic monitoring results generated through a successive type inference engine are displayed in user-friendly graphics. The validity and reliability of the developed system is verified to be a powerful commercial version on a vertical machining center through a series of experiments.

  • PDF

Remote Measurement System with PCS and One Chip Microcontroller (PCS와 원칩 마이크로콘트롤러를 이용한 원격 검침 시스템)

  • 이지홍;하인수;김인식
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.171-174
    • /
    • 2000
  • In stead of RF module which has been used conventionally in many remote measurement applications, a new type of remote measurement system based on PCS(Personal communication system) and one chip Microcontroller is proposed in this work. PCS has many advantages with respect to cost reliability, communication quality, and so on. The proposed system consists of three different modules: PCS module, micro-controller module, and sensor module. System configuration as well as illustrative experiments will be described in detail.

  • PDF

A Study on The Power Line Communication Module for a Rainwater Management System (빗물관리 시스템을 위한 전력선 통신 모듈에 관한 연구)

  • Jung, Yong-Chae;Jung, Ho-Seok;Kim, Jeong-Uk
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.500-502
    • /
    • 2007
  • In case Power Line Communication (PLC) method is applied to a rainwater monitoring system, PLC module should be utilized. In this paper, PLC module using ST7538Q is implemented. The design rules of the IC peripheral circuit are explained in detail. The operation of the implemented PLC module is verified through the experimental results.

  • PDF

Electrical Loss Reduction in Crystalline Silicon Photovoltaic Module Assembly: A Review

  • Chowdhury, Sanchari;Kumar, Mallem;Ju, Minkyu;Kim, Youngkuk;Han, Chang-Soon;Park, Jinshu;Kim, Jaimin;Cho, Young Hyun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.7 no.4
    • /
    • pp.111-120
    • /
    • 2019
  • The output power of a crystalline silicon (c-Si) photovoltaic (PV) module is not directly the sum of the powers of its unit cells. There are several losses and gain mechanisms that reduce the total output power when solar cells are encapsulated into solar modules. Theses factors are getting high attention as the high cell efficiency achievement become more complex and expensive. More research works are involved to minimize the "cell-to-module" (CTM) loss. Our paper is aimed to focus on electrical losses due to interconnection and mismatch loss at PV modules. Research study shows that among all reasons of PV module failure 40.7% fails at interconnection. The mismatch loss in modern PV modules is very low (nearly 0.1%) but still lacks in the approach that determines all the contributing factors in mismatch loss. This review paper is related to study of interconnection loss technologies and key factors contributing to mismatch loss during module fabrication. Also, the improved interconnection technologies, understanding the approaches to mitigate the mismatch loss factors are precisely described here. This research study will give the approach of mitigating the loss and enable improvement in reliability of PV modules.

A Study on Analysis of Disturbance in VLC Transceiver Module Based on LED Communication (LED 조명통신용 드라이빙기술 기반 VLC 송수신기 모듈의 외란광 분석에 관한 연구)

  • Hong, Geun-Bin;Jang, Tae-Su;Kim, Tae-Hyung;Kim, Yong-Kab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1391-1395
    • /
    • 2011
  • In this paper, would implement a transceiver for the visible light communication that based on wireless communication driving technology for LED illumination-based infrared ray communication, and measurement analyzed a design error rate of a transceiver variable rate has made about distance change -2.5m. The error rate measured a voltage variable along illuminate change between switchable circumstances, which has illuminated insight and outright. Each analyzed and measurement on the communication distance errors along the differences of disturbance light between night and days. The LED module has implemented for number of 6 through illumination dimming in case of different values. Also, implementation for the system module of a VLC transceiver based on the infrared sensors which used feedback outcome value has analyzed with error rate.

Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

Industrial Communication Gateway Design of Communications Module Additive layer type (통신 모듈 적층형 산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Nam, Jae Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.133-136
    • /
    • 2019
  • Recently, many industrial devices are facing protocol compatibility problems with external monitoring and control systems. This paper designed an industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using rs485 serial communication to multiple layers. Each communication module consisted of analog data card, a digital data card LAN, and a CAN-enabled card. The main board processor used Atmega micro-processor, and the rs485 serial slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

  • PDF