• Title/Summary/Keyword: Communication Control Unit

Search Result 499, Processing Time 0.033 seconds

A Switchgear Controller for Distribution Automatic System (배전자동화용 일체형 개폐기 콘트롤러)

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.;Kim, M.J.;Choi, S.H.;Lee, B.O.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2190-2192
    • /
    • 1997
  • Recently, the research of the distribution automatic system is increased. Distribution automatic system in local switchgear side usually consists of a switchgear controller and a feeder remote unit. A feeder remote unit (FRU) analyzes remote control order from the sudstation communication control unit(SCCU) located remote position using MODEM and delivers order to a switchgear controller. The each state of a switchgear is also delivered to a SCCU through a FRU. Switchgear controller operates switchgear directly and collects the each state of switchgear. In this system between a FRU and a switchgear controller, there are many functions which is included both of them. In this paper the combined switchgear controller which unified the conventional control functions of a FRU and a swichgear controller is proposed. The combined switchgear controller has many advantages excluding redundancy in system cost, space, control reliability and etc.

  • PDF

Adaptive Basic Unit Level Rate Control for H.264 (적응적 베이직 유닛 레벨 H.264 비트율 제어)

  • Park, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.355-361
    • /
    • 2009
  • This paper proposes a new basic unit level rate control algorithm which generates the output bits corresponding to the target bits. The H.264 standard uses various coding modes and optimization methods to improve the compression performance, which makes it difficult to control the generated traffic accurately. In the proposed scheme, the allocated bits to a frame are distributed to all basic units properly to encode each basic unit according to the bit budget. After encoding the frame, the encoding parameters are adjusted according to the difference between the target and the resulting values. It is shown by experimental results that the new algorithm can generate output bit rates accurately corresponding to the target bit rates with the PSNR performance better than that of the existing rate control algorithm.

Implementation Methods of Multipoint Control Unit (집중식 영상회의를 위한 다지점 제어 장치의 구현 방안)

  • Seong, Dong-Su;Ham, Jin-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.3
    • /
    • pp.277-287
    • /
    • 1995
  • For multipoint video conference of using multimedia communication terminals, terminals are logically connected each other, and there are centralized method and distributed method in connection between terminals. Multipoint control unit is needed for the centralized method, there are two methods for implementaion such as digital method and analog method. For a meaning and implementation method of multipoint control init, main funtions of multipoint control unit are summarized and the various implementation methods are proposed in this paper.

  • PDF

Development of Platform for Connection of Electronic Power Backbone based on D-TRS (D-TRS 기반 전력기간망 접속을 위한 게이트웨이 플랫폼 개발)

  • Song, Byeong-Kwon;Lee, Sang-Hun;Jeong, Tae-Eui;Kim, Gun-Woong;Kim, Jin-Chul;Kim, Young-Eok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.382-384
    • /
    • 2008
  • D-TRS is a method of wireless communication. This method will be able to use several frequency for multiple user used chanel together. TETRA of D-TRS technology is not rented network. Using TETRA network has the strong point which cost better than CDMA network of rental network. Master server of SCADA(Supervisory Control And Data Acquisition) system is realtime supervise control and a data acquire the control system or the RTU(Remote Terminal Unit). The present paper is developed and proposal the gateway platform for electronic power backbone network based on D-TRS. This gateway platform is converted DNP3.0 messages with TETRA PDU and converted TETRA PDU with DNP3.0 messages. Master server and FRTU will be able to send and receive DNP3.0 message via TETRA network using this gateway platform.

  • PDF

Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator (상업용 냉장고의 상황 감지를 위한 인버터형 실외기 신호 분석)

  • Lim, Hyo Joon;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Kyung Chang;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.517-523
    • /
    • 2016
  • Unlike household refrigerators, commercial refrigerators are composed of separate indoor and outdoor units. The outdoor unit of most commercial refrigerators is designed to run at a fixed speed, which results in low energy efficiency and loud fan noise. Moreover, it cannot respond flexibly to changing thermal load in the indoor unit. Inverter type outdoor units can address such problems through speed changes based on information obtained from the indoor unit. However, using two units from different manufacturers is often not a viable solution. If condition changes in the indoor unit can be detected without communication between the two units, it is possible to adjust the speed of the outdoor unit. This paper attempts to analyze the signal from the outdoor unit when the condition of the indoor unit changes by varying the thermal load.

A Study of Payload Interface Unit Design for COMS (Communication Ocean & Meteorological Satellites) (통신해양기상위성의 탑재체 접속장치 설계에 관한 연구)

  • Cho, Young-Ho;Won, Joo-Ho;Choi, Jae-Dong;Yang, Koon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.369-370
    • /
    • 2008
  • The Payload Interface Unit (PIU) provides the interface between payload equipment (GOCI, MODCS and Ka Band P/L) and the SCU. The PIU is a MIL-STD-1553-Bus Remote Terminal (RT). The MPIU distributes commands to, acquires telemetry from and takes part in the thermal control of the payload equipment. When in ON mode, the PIU is completely observable and can be used for payload control. When in OFF mode, the PIU is non active except the thermal control electronics.

  • PDF

Single-phase Uninterruptible Power Supply employing Superconducting Magnet Energy Storage Unit

  • Kang, Feel-Soon
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.362-368
    • /
    • 2007
  • A single-phase uninterruptible power supply system equipped with a superconducting magnet energy storage unit is proposed to achieve a simple circuit configuration and higher system reliability. It reduces a number of switching devices by applying a common-arm scheme. Removing some switches or substituting passive elements for active switches can increase the sophistication and reduces degree of freedom in control strategy. However, high-performance DSP controller can execute the complicated control task with no additional cost. Operational principles to normal, stored-energy, and bypass mode are discussed in detail. The validity of the proposed system is verified by experimental results.

The Development of Body Control Module using In Vehicle Network

  • Lee, Seong-Hun;Wu, Son-Jun;Lee, Suk;Choi, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.174.2-174
    • /
    • 2001
  • Increasing demand for safety features, driving comfort and operational convenience in automobiles requires an intensive use of electronic components such as sensors, actuators and Electronic Control Unit(ECU)'s. These growing number of electronics has given rise to problems concerning the increasing number, size and weight of the wiring harnesses. In order to resolve these problems, multiplexed wiring systems such as Controller Area Network(CAN) serial communication protocol are applied in vehicle. This paper introduces the development of Body Control Module(BCM)s using multiplexed wiring systems. The BCM's were developed and implemented using CAN, the most popular choice of in-vehicle communication protocols.

  • PDF

Development of the Winch Control System for Floating Island and Statistics Analysis for Data (한강 인공섬 윈치 제어시스템 개발과 테이터 통계 분석)

  • Kim, Sang-Young;Park, Soo-Hong;Park, Jee-Yeun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.309-315
    • /
    • 2012
  • We develpoed auto winch control which will be applied when we want to fix ship or marine structure in the ocean. In this paper, an effort has been made to design and develop a control unit for Winch control purpose. Developed result shows usefulness when it is applied to Han-river floating island.

A study of Water Level Control System (수위관리 시스템 연구)

  • Park, Yong-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.5
    • /
    • pp.504-508
    • /
    • 2010
  • A reducing labor is a big issue in rural community due to a increasingly aging society. In this paper, the water control system for corps production with a function of automatically controls and solar energy system is developed. The water level was measured by ultrasonic sensor and water gate was controlled by using servo motor. The system had included ATmega 128 control unit for signal controls. The water level control system will be able to contribute to the aging rural society.