• Title/Summary/Keyword: Common-mode suppression

Search Result 24, Processing Time 0.025 seconds

The Suppression of both leakage current and common-mode voltage occurring three phase PWM voltage type inverter (3상 PWM 전압형 인버터에 발생하는 누설전류와 동상모드 전압의 억제)

  • Mun, S.P.;Suh, K.Y.;Kwon, S.K.;Kim, J.Y.;Kim, Y.M.;Kim, H.J.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1515-1517
    • /
    • 2005
  • In this paper, we represent both occurrence reason of Surge-voltage and Leakage-current of AC drive system which is operated by Voltage-type PWM Inverter. It generates a compensating voltage which has the same amplitude as, but the opposite phase to, the common-mode voltage produced by the PWM inverter. The compensating voltage is superimposed on the inverter output by a common-mode transformer. As a result, the common-mode voltage applied to the load is canceled completely. The design method of the active common-mode noise canceler is also presented in detail. Therefore, we try to describe the method controling both of them and all of the proprieties are proved by our experiment.

  • PDF

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

Common Mode Filter Embedded in Flexible Printed Circuit Board for Multi-Function Cable (다기능 케이블을 위한 연성 회로 기판에 내장된 공통 모드 필터)

  • Byun, Jin-Do;Jung, Sang-Woon;Lee, Keun-Hyung;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.343-351
    • /
    • 2008
  • In this paper, a spiral shaped common mode filter(CMF) embedded in a flexible printed circuit board(FPCB) is proposed for a multi-function cable. The CMF embedded in a FPC cable presents a new concept as a multi-function cable by the common mode rejection characteristics without a surface mounted device(SMD) CMF. The embedded CMF has a wideband common mode rejection bandwidth and an enhanced differential mode characteristics compared to conventional CMFs that use a magnetic material such as a ferrite of high loss. The proposed CMF of 3 turn inductors has a common mode rejection bandwidth from 0.4 GHz to 3.12 GHz and has 1.95 dB at 3 GHz, 6.97 dB at 8 GHz improvements of a differential mode insertion loss compared to the commercial LTCC(Low Temperature Co-fire Ceramics) CMFs.

Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection (중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제)

  • Bae, Young-Sang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

Balanced Mixer Based on Composite Right/Left-Handed Transmission Line Leaky-Wave Antenna (CRLH 전송 선로 리키 웨이브 안테나를 이용한 평형 믹서)

  • Kim, Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.985-991
    • /
    • 2008
  • This paper presents a novel balanced mixer receiver front-end design based on a metamaterial structure applicable to differential-/common-mode excitation. This metamaterial structure functions as a leaky-wave antenna and provides in-trinsic common-mode suppression. Low LO leakage and high RF to LO isolation are achieved without additional filters for LO and RF paths. The metamaterial is based on a unit-cell which under a differential-mode excitation behaves like a composite right/left-handed(CRLH) metamaterial. In contrast, the metamaterial unit-cell is below cut-off under a common-mode excitation. Experimental results are used to verify the proposed metamaterial's differential-/common-mode characteristics. The metamaterial is integrated with a balanced mixer design resulting in an operation frequency range of $1.96{\sim}2.40$ GHz with an optimum mixer conversion loss of 21.1 dB at 2,4 GHz.

Study on the analysis and suppression of conducted noise from switching converter by the mode separation technique (모드 분리 기법을 이용한 스위치 컨버터의 전도잡음 분석 및 대책에 관한 연구)

  • 김진성;권준혁;김양모
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.4
    • /
    • pp.128-138
    • /
    • 1998
  • This paper describes a principle of the conducted noise separator which can separate the conducted noise to the common mode and differential mode(normal mode), and presents the transfer characteristics of the separator designed and manufactured. We separated the conducted noise generated from switched mode converter to the CM and DM conducted noise, and also analyzed the source and path of conducted noise in the converter by the conducted noise separator. Since we could easily get the characteristics of the CM and DM conducted noise by the separator, we could efficiently determine the contermeasures for the reduction of the conducted noise and establish the foundation of the systematic procedure for the design of low pass filter.

  • PDF

Suppression of leakage and crosstalk in millimeter-wave flip-chip packages (밀리미터파 플립 칩 실장구조에서의 누설파와 간섭효과 억제방법)

  • 이계안;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.40-46
    • /
    • 1998
  • Leakage phenomena of flip-chip structures on common GaAs and alumina main substrates are characterized using the spectral domain approach to reduce the possible chip-to-chip crosstald and transmission resonance. We have found taht the longitudinal section magnetic mode is dominant for the coplanar waveguide leakage andthe leakage can be suppreassed by properly managing the gap height and the main substrate thickness in addition to the dielectric constant. These calculation results will be helpful for designing and flip-chip packagaing of high-frequency integrated circuits.

  • PDF

A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant (LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bum;Hwang, Young-Rok;Kim, Yong-Kwan;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

Suppression of Shaft Voltage by Rotor and Magnet Shape Design of IPM-Type High Voltage Motor

  • Kim, Kyung-Tae;Cha, Sang-Hoon;Hur, Jin;Shim, Jae-Sun;Kim, Byeong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.938-944
    • /
    • 2013
  • In this paper, we propose a method for suppressing shaft voltage by modifying the shape of the rotor and the permanent magnets in interior permanent magnet-type-high-voltage motors. Shaft voltage, which is induced by parasitic components and the leakage flux in motor-driven systems, adversely affects their bearings. In order to minimize shaft voltage, we designed a magnet rearrangement and rotor re-structuring of the motor. The shaft voltage suppression effect of the designed model was confirmed experimentally and by comparative finite element analysis.

Suppression of Current Harmonics with Triple Delta Sourced Winding and Novel Connection of Common-mode Filter (4권선 변압기의 삼중 델타 전원 연결과 새로운 커먼-모드 필터 연결방법을 이용한 전류 고조파 저감)

  • Ohn, Sungjae;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.245-246
    • /
    • 2015
  • 본 논문에서는 삼중 델타 전원과 새로운 커먼-모드 필터 결선을 통해 스위칭에 의한 고조파를 저감하는 방법을 제안한다. PWM에 의해 생성되는 측대파 고조파(Sideband harmonics) 위상을 분석함으로써, 인터리빙 운전 시 삼중 델타 전원 연결과 제안된 커먼모드 필터가 측대파 고조파 전류를 크게 저감할 수 있음을 보인다. 3개의 고정자 권선을 가지는 영구자석 전동기를 이용하여 제안된 필터의 유효성을 검증하였다.

  • PDF