• Title/Summary/Keyword: Common load

Search Result 599, Processing Time 0.026 seconds

Implementation of SLA Management System for QoS Guarantee in Cloud Computing Environment (클라우드 환경에서 QoS 보장을 위한 SLA 관리시스템 구현)

  • Yoon, Ka-Ram;Lee, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.302-308
    • /
    • 2013
  • Internet is becoming more common with increasing cloud services have been spreading rapidly. A SLA is agreements between service providers and customers of service providers is how to ensure quality of service. SLA in cloud computing environments from the perspective of the IT service providers to customer satisfaction increase for service quality, it will need to differentiate between competing carriers QoS guarantees with SLA is a very important factor. However, the study of SLA in the cloud is staying in its infancy. In this paper, SLA indices for cloud services defining and use them SLA Management System for QoS guarantee has been implemented. The proposed system using monitoring-based migration policy an open source-based cloud computing platform which Cluster Nodes load distribution of virtual machines assigned to their availability, response time, throughput analysis of what affects and is compared with existing cloud.

A Single-Phase Embedded Z-Source DC-AC Inverter by Asymmetric Voltage Control (비대칭 전압 제어를 이용한 단상 임베디드 Z-소스 DC-AC 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • In case of the conventional DC-AC inverter using two DC-DC converters with unipolar output capacitor voltages, for generating the AC output voltage, the output capacitor voltages of its each DC-DC converter must be higher than the DC input voltage. To solve this problem, this paper proposes a single-phase DC-AC inverter using two embedded Z-source converters with bipolar output capacitor voltages. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The AC output voltage is obtained by the difference of the output capacitor voltages of each converter. Though the output capacitor voltage of converter is relatively low compared to the conventional method, it can be obtained the same AC output voltage. Moreover, by controlling asymmetrically the output capacitor voltage, the AC output voltage of the proposed system is higher than the DC input voltage. To verify the validity of the proposed system, a DSP(TMS320F28335) based single-phase embedded Z-source DC-AC inverter was made and the PSIM simulation was performed under the condition of the DC source 38V. As controlled symmetrically and asymmetrically the output capacitor voltages of each converter, the proposed inverter could produce the AC output voltage with sinusoidal waveform. Particularly, in case of asymmetric control, a higher AC output voltage was obtained. Finally, the efficiency of the proposed system was measured as 95% and 97% respectively in case of symmetric and asymmetric control.

A Development of Small-diameter Composite Helical Spring for Reinforcement of Optical Fiber Jumper Cord (OJC) (광점퍼코드 (OJC) 보호용 미소 직경 복합재료 스프링 개발)

  • 윤영기;박성도;이연수;윤희석;이우일
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.17-22
    • /
    • 2002
  • Small diameter composite helical springs (CS) are developed using a hot plated mold for reinforcement of common optical fiber jumper cord (OJC). The outer diameters of the springs are about 2 ~ 3mm. These springs are inserted into the OJC to protect the damage of an optical fiber from the sudden lateral load. Two types of CS, Yarn type (Y-type) and Band type (B-type), are manufactured to compare the effectiveness for the damage protection. The experimental works were conducted to check the effect of the CS covered around OJC on the mechanical and optical properties. Experimental observations show a considerable effect on the flexural resistance, hence slowing down the deterioration of the optical power by the internal damage of the fiber. Obtained main results are as follows: (1) Y-type CS has better protection abilities to lateral loading than B-types. (2) Compared with bare OJC, CS-OJC has less power loss under the loading. (3) OJC covered with the composite coil spring has a possibility for a practical usage with full fruits.

A Study on the Engine Performance and Emission Characteristics in a LP EGR System with Electronic Throttle Control (ETC를 적용한 저압 EGR시스템의 엔진성능 및 배출가스 특성에 관한 연구)

  • Park, Jun-Heuk;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.379-387
    • /
    • 2011
  • Research and development of LP EGR system for the performance improvement and emission reduction on diesel engine is proceeding at a good pace. LP EGR system seems to be helpful method to further reduce$NO_x$ emissions while maintaining PM emissions at a low level because the boost pressure is unchanged while varying EGR rate. This study is experimentally conducted on a 2.0L common rail DI engine at the medium load condition (2000 rpm, BMEP 1.0 MPa, boost pressure 181.3 kPa) that difficult to use large amount of EGR gas because of deteriorations of performance and fuel consumption. And we investigated the characteristics of performance and fuel consumption while varying EGR systems. The overall results using LP EGR system equipped with ETC identified benefits on reduction of PM and improvement of fuel consumption and thermal efficiency while keep the $NO_x$ level compared to HP EGR and LP EGR with back pressure valve.

Late Cytomegalovirus Disease Causes Ileal Perforation after Kidney trasplantation (신 이식 후 소장 파열을 초래한 후기 cytomegalovirus 질환)

  • Lee, Hee-Woo;Hahn, Hye-Won;Park, Young-Seo
    • Childhood Kidney Diseases
    • /
    • v.15 no.1
    • /
    • pp.76-80
    • /
    • 2011
  • Cytomegalovirus (CMV) is the single most common infection following kidney transplantation and despite prophylactic strategies and the development of new antiviral agents, it still remains a cause of considerable morbidity and mortality. Current literature suggests that CMV infection may trigger rejection. We report a case of late CMV disease in a preemptive seropositive recipient who did not receive CMV prophylaxis. Diarrhea and abdominal cramping persisted after the administration of mycophenolate mofetil (MMF) six months after transplantation and resulted in ileal perforation at eight months after transplantation. The boy recovered after six weeks of treatment with ganciclovir. MMF has been mooted as a risk factor for CMV infection since its introduction, and further investigations are required to confirm its role. More attention to infectious complications is necessary and serial monitoring of viral load is recommended when MMF is administered.

Study and Evaluation of Sub Area Linkage Algorithm in COSMOS (COSMOS에서의 Sub Area 운영 알고리즘에 관한 연구 및 평가)

  • Lee, Young-Ihn;Kim, Sang-Yoon
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.2 s.73
    • /
    • pp.109-119
    • /
    • 2004
  • In COSMOS, an area for signal coordination is divided into subareas composed of several signalized intersections that share a common cycle time. Each subarea contains only one critical intersection having heavy traffic load. Subarea is a basic unit of control. The performance of COSMOS is highly dependent on the linkage rule between adjacent subareas. The purpose of this study is to provide an appropriate subarea linkage rule in COSMOS. This study developed a control strategy for Critical Intersection and Sub Area linkage. Critical Intersections calculate the Offset Pattern both East-West Axis and North-South Axis, and the coordination direction either East-West Axis or North-South Axis. Subarea can be combined with other one in all directions. The performance of the suggested linkage rule was evaluated on the real network in Gangnam-Gu. The result was that travel time was reduced by the suggested linkage rule.

Psychophysical Discomfort Evaluation of Complex Trunk Postures (복합적인 몸통 자세의 심물리학적 불편도 평가)

  • Lee, In-Seok;Ryu, Hyung-Gon;Chung, Min-K.;Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.4
    • /
    • pp.413-423
    • /
    • 2001
  • Low back disorders (LBDs) are one of the most common and costly work-related musculoskeletal disorders. One of the major possible risk factors of LBDs is to work with static and awkward trunk postures, especially in a complex trunk posture involving flexion, twisting and lateral bending simultaneously. This study is to examine the effect of complex trunk postures on the postural stresses using a psychophysical method. Twelve healthy male students participated in an experiment, in which 29 different trunk postures were evaluated using the magnitude estimation method. The results showed that subjective discomfort significantly increased as the levels of trunk flexion, lateral bending and rotation increased. Significant interaction effects were found between rotation and lateral bending or flexion when the severe lateral bending or rotation were assumed, indicating that simultaneous occurrence of trunk flexion, lateral bending and rotation increases discomfort ratings synergistically. A postural workload evaluation scheme of trunk postures was proposed based on the angular deviation levels from the neutral position. Each trunk posture was assigned numerical stress index depending upon its discomfort rating, which was defined as the ratio of discomfort of a posture to that of its neutral posture. Four qualitative action categories for the stress index were also provided in order to enable practitioners to apply corrective actions appropriately. The proposed scheme is expected to be applied to several field areas for evaluating trunk postural stresses.

  • PDF

Temperature Fluctuations Over the Past 2000 Years in Western Mongolia

  • Pederson, Neil;Jacoby, Gordon C.;D′Arrigo, Rosanne.;Frank, David;Buckley, Brendan;Nachin, Baatarbileg;Chultem, Dugarjav;Renchin, Mijiddorj
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.157-159
    • /
    • 2003
  • Much of northern Asia is lacking in high-resolution palaeoclimatic data coverage. This vast region thus represents a sizeable gap in data sets used to reconstruct hemispheric-scale temperature trends for the past millennium. To improve coverage, we present a regional-scale composite of four tree-ring width records of Siberian pine and Siberian larch from temperature-sensitive alpine timber-line sites in Mongolia. The chronologies load closely in principal components analysis (PCA) with the first eigenvector accounting for over 53% of the variance from ad 1450 to 1998. The 20-year interval from 1974 to 1993 is the highest such growth period in this composite record, and 17 of the 20 highest growth years have occurred since 1946. Thus these trees, unlike those recently described at some northern sites, do not appear to have lost their temperature sensitivity, and suggest that recent decades have been some of the warmest in the past 500 years for this region. There are, however, comparable periods of inferred, local warmth for individual sites, e.g., in 1520-1580 and 1760-1790. The percent common variance between chronologies has increased through time and is highest (66.1%) in the present century. Although there are obvious differences among the individual chronologies, this result suggests a coherent signal which we consider to be related to temperature. The PCA scores show trends which strongly resemble those seen in recent temperature reconstructions for the Northern Hemisphere, very few of which included representation from Eurasia east of the Ural Mountains. The Mongolia series therefore provides independent corroboration for these reconstructions and their indications of unusual wanning during the twentieth century.

  • PDF

Precision Assessment of Near Real Time Precise Orbit Determination for Low Earth Orbiter

  • Choi, Jong-Yeoun;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.1
    • /
    • pp.55-62
    • /
    • 2011
  • The precise orbit determination (POD) of low earth orbiter (LEO) has complied with its required positioning accuracy by the double-differencing of observations between International GNSS Service (IGS) and LEO to eliminate the common clock error of the global positioning system (GPS) satellites and receiver. Using this method, we also have achieved the 1 m positioning accuracy of Korea Multi-Purpose Satellite (KOMPSAT)-2. However double-differencing POD has huge load of processing the global network of lots of ground stations because LEO turns around the Earth with rapid velocity. And both the centimeter accuracy and the near real time (NRT) processing have been needed in the LEO POD applications--atmospheric sounding or urgent image processing--as well as the surveying. An alternative to differential GPS for high accuracy NRT POD is precise point positioning (PPP) to use measurements from one satellite receiver only, to replace the broadcast navigation message with precise post processed values from IGS, and to have phase measurements of dual frequency GPS receiver. PPP can obtain positioning accuracy comparable to that of differential positioning. KOMPSAT-5 has a precise dual frequency GPS flight receiver (integrated GPS and occultation receiver, IGOR) to satisfy the accuracy requirements of 20 cm positioning accuracy for highly precise synthetic aperture radar image processing and to collect GPS radio occultation measurements for atmospheric sounding. In this paper we obtained about 3-5 cm positioning accuracies using the real GPS data of the Gravity Recover and Climate Experiment (GRACE) satellites loaded the Blackjack receiver, a predecessor of IGOR. And it is important to reduce the latency of orbit determination processing in the NRT POD. This latency is determined as the volume of GPS measurements. Thus changing the sampling intervals, we show their latency to able to reduce without the precision degradation as the assessment of their precision.

A new precast wall connection subjected to monotonic loading

  • Vaghei, Ramin;Hejazi, Farzad;Taheri, Hafez;Jaafar, Mohd Saleh;Ali, Abang Abdullah Abang
    • Computers and Concrete
    • /
    • v.17 no.1
    • /
    • pp.1-27
    • /
    • 2016
  • Final construction project cost is significantly determined by construction rate. The Industrialized Building System (IBS) was promoted to enhance the importance of prefabrication technology rather than conventional methods in construction. Ensuring the stability of a building constructed by using IBS is a challenging issue. Accordingly, the connections in a prefabricated building have a basic, natural, and essential role in providing the best continuity among the members of the building. Deficiencies of conventional precast connections were observed when precast buildings experience a large induced load, such as earthquakes and other disasters. Thus, researchers aim to determine the behavior of precast concrete structure with a specific type of connection. To clarify this problem, this study investigates the capacity behavior of precast concrete panel connections for industrial buildings with a new type of precast wall-to-wall connection (i.e., U-shaped steel channel connection). This capacity behavior is compared with the capacity behavior of precast concrete panel connections for industrial buildings that used a common approach (i.e., loop connection), which is subjected to monotonic loading as in-plane and out-of-plane loading by developing a finite element model. The principal stress distribution, deformation of concrete panels and welded wire mesh (BRC) reinforcements, plastic strain trend in the concrete panels and connections, and crack propagations are investigated for the aforementioned connection. Pushover analysis revealed that loop connections have significant defects in terms of strength for in-plane and out-of-plane loads at three translational degrees of freedom compared with the U-shaped steel channel connection.