• Title/Summary/Keyword: Common Leg

Search Result 173, Processing Time 0.031 seconds

Sleep Apnea in Older Adults (노인에서의 수면무호흡)

  • Moon, Hwa-Sik;Lee, Sang-Haak
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.1
    • /
    • pp.13-19
    • /
    • 2007
  • Sleep disordered breathing is highly prevalent in the elderly and affects older men and women similarly. Nocturia, cardiovascular diseases, cognitive impairment, traffic accidents and repeated falls are common manifestations of sleep apnea in the elderly and sleep study may be indicated in these patients. When a sleep study is planned, reliable markers of respiratory efforts and a tibial EMG should be included because central sleep apneas and periodic leg movements are common in the elderly patients. Although cardiovascular morbidity and mortality seem to be lower in the elderly than in middle-aged adults, these may not be as low as commonly believed. Excessive daytime sleepiness, cognitive dysfunction and nocturia can be improved by effective treatment with continuous positive airway pressure and a therapeutic trial should be recommended to all symptomatic patients. It is still unclear whether sleep apnea in older adults is a specific entity or the same disease as in younger adults. Further clinical research is warranted.

  • PDF

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감 방법)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.287-288
    • /
    • 2014
  • 본 논문에서는 3레벨 4레그 컨버터에서 커먼 모드 전압(Common-mode Voltage, CMV)을 저감하기 위한 삼각파 비교 전압 변조 기법을 제안하였다. 제안한 PWM 방법은 매우 직관적이고, DSP 제어 시스템에서 쉽게 구현할 수 있다. SVPWM, SPWM의 스위칭 패턴 분석을 통하여 CMV 저감을 위한 4번째 레그(f상)의 극 전압 패턴을 제안하였고, 해당하는 f상 극 전압의 합성을 위하여, f상 양/음의 극 전압 지령 값을 계산하였다. 또한 a, b, c상 전압 왜곡을 막기 위한 옵셋 전압을 유도하였다. 제안한 PWM 방법의 유효성은 모의실험과 실험 결과를 통하여 검증되었다. 제안된 방법에서 CMV의 첨두치 및 스위칭 수는 SVPWM 방법에 비하여 각각 33%, 25%로 대폭 감소하였다.

  • PDF

Adventitial Cystic Disease of the Common Femoral Vein Mimicking Deep Venous Thrombosis: A Case Report (심부 정맥 혈전으로 오인된 총대퇴정맥에 생긴 외막낭성질환: 증례 보고)

  • Sun Ha Min;Jae Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1315-1320
    • /
    • 2021
  • Adventitial cystic disease of the vein is a rare vascular disease. Herein, we report a case of adventitial cystic disease of the common femoral vein that was initially misdiagnosed as deep venous thrombosis in a 41-year-old male who presented with leg swelling. We focused on the imaging findings and compared them with those of deep venous thrombosis.

Drilling Gas Hydrate at Hydrate Ridge, ODP Leg 204

  • Lee Young-Joo;Ryu Byong-Jae;Kim Ji-Hoon;Lee Sang-Il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.663-666
    • /
    • 2005
  • Gas hydrates are ice-like compounds that form at the low temperature and high pressure conditions common in shallow marine sediments at water depths greater than 300-500 m when concentrations of methane and other hydrocarbon gases exceed saturation. Estimates of the total mass of methane carbon that resides in this reservoir vary widely. While there is general agreement that gas hydrate is a significant component of the global near-surface carbon budget, there is considerable controversy about whether it has the potential to be a major source of fossil fuel in the future and whether periods of global climate change in the past can be attributed to destabilization of this reservoir. Also essentially unknown is the interaction between gas hydrate and the subsurface biosphere. ODP Leg 204 was designed to address these questions by determining the distribution, amount and rate of formation of gas hydrate within an accretionary ridge and adjacent basin and the sources of gas for forming hydrate. Additional objectives included identification of geologic proxies for past gas hydrate occurrence and calibration of remote sensing techniques to quantify the in situ amount of gas hydrate that can be used to improve estimates where no boreholes exist. Leg 204 also provided an opportunity to test several new techniques for sampling, preserving and measuring gas hydrates. During ODP Leg 204, nine sites were drilled and cored on southern Hydrate Ridge, a topographic high in the accretionary complex of the Cascadia subduction zone, located approximately 80km west of Newport, Oregon. Previous studies of southern Hydrate Ridge had documented the presence of seafloor gas vents, outcrops of massive gas hydrate, and a pinnacle' of authigenic carbonate near the summit. Deep-towed sidescan data show an approximately $300\times500m$ area of relatively high acoustic backscatter that indicates the extent of seafloor venting. Elsewhere on southern Hydrate Ridge, the seafloor is covered with low reflectivity sediment, but the presence of a regional bottom-simulating seismic reflection (BSR) suggests that gas hydrate is widespread. The sites that were drilled and cored during ODP Leg 204 can be grouped into three end-member environments basedon the seismic data. Sites 1244 through 1247 characterize the flanks of southern Hydrate Ridge. Sites 1248-1250 characterize the summit in the region of active seafloor venting. Sites 1251 and 1252 characterize the slope basin east of Hydrate Ridge, which is a region of rapid sedimentation, in contrast to the erosional environment of Hydrate Ridge. Site 1252 was located on the flank of a secondary anticline and is the only site where no BSR is observed.

  • PDF

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

Landing Performance of a Quadruped Robot Foot Having Parallel Linked Toes on Uneven Surface (평행링크형 발가락을 갖는 4족 보행로봇 발의 비평탄 지면 착지 성능)

  • Hong, Yeh-Sun;Yoon, Seung-Hyeon;Kim, Min-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.47-55
    • /
    • 2009
  • In this study, a robot foot having toes for firm stepping on uneven surface is proposed. The toes are connected to the lower leg by parallel links so that the lower leg can rotate in the rolling and pitching directions during stance phase without ankle joint. The landing performance of the foot on uneven surface was evaluated by relative comparison with that of the most common foot making point contact with the walking surface, since the test conditions considering real uneven surface could be hardly defined for its objective evaluation. Anti-slip margin(ASM) was defined in this study to express the slip resistance of a robot foot when it lands on a projection with half circular-, triangular- or rectangular cross section, assuming that uneven surface consists of projections having these kind of cross sections in different sizes. Based on the ASM analysis, the slip conditions for the two feet were experimentally confirmed. The results showed that the slip resistance of the new foot is not only higher than that of the conventional point contact type foot but also less sensitive to the surface friction coefficient.

A Comparative Study of the Effects of Proprioceptive Neuromuscular Facilitation and Taping Interventions on Balance Ability, Joint Position Sense, and Ankle Joint Strength (발목관절 근력과 관절위치감각, 그리고 균형능력에 미치는 고유수용성 신경근 촉진법 중재와 테이핑 중재 비교연구)

  • Kim, Jwa-jun;Park, Se-Yeon
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: The aim of the present study was to investigate the effects of proprioceptive neuromuscular facilitation (PNF) and taping interventions on balance ability, joint position sense, and ankle joint strength. Methods: Thirty subjects who had experienced an ankle sprain within the previous 3 months participated in this study. The subjects were randomly assigned to a PNF group (n=15) or a taping group (n=15). Before and after the interventions, ankle dorsi-flexion and plantar-flexion strength, joint position error, and total center of pressure movements in one leg while in a standing position were measured. Results: Regardless of the group allocation, ankle dorsi-flexion and plantar-flexion strength significantly improved after the interventions (p<0.05). Compared to preintervention measurements, joint position errors were significantly reduced postintervention (p<0.05). The PNF intervention significantly decreased the total lateral movement of the center of pressure in the one leg standing condition (p<0.05). Conclusion: Both PNF and taping interventions improved joint position sense and ankle joint strength. In common with the findings of a previous study, the PNF intervention improved balance ability. Further study is required to investigate the effects of various PNF and taping interventions on ankle performance in subjects with chronic ankle sprains.

Effect of Ankle Taping Type and Jump Height on Balance during Jump Landing in Chronic Ankle Instability

  • Kim, Mikyoung;Kong, Byungsun;Yoo, Kyungtae
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2077-2089
    • /
    • 2020
  • Background: Chronic ankle instability is a common injury that decreases balance and negatively affects functional movements, such as jumping and landing. Objectives: To analyze the effect of taping types and jump heights on balance with eyes open and closed during jump landings in chronic ankle instability. Design: Within-subject design. Methods: The study involved 22 patients with chronic ankle instability. They performed both double-leg and single-leg drop jump landings using three conditions (elastic taping, non-elastic taping, and barefoot) on three different jump platforms (30, 38, and 46 cm). Balance was measured using the Romberg's test with eyes open and closed. Results: Interaction effect was not statistically significant. Balance with eyes open and closed was significantly improved in both the elastic taping and non-elastic taping conditions compared to the barefoot condition. There was no significant difference according to the jump height. Conclusion: Individuals with chronic ankle instability demonstrated increased balance ability with eyes open and closed when jump landing. Elastic taping and non-elastic taping on the ankle joint can positively affect balance during landing in individuals with chronic ankle instability.

ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.928-940
    • /
    • 2017
  • An experiment using the $Prim{\ddot{a}}rkreisl{\ddot{a}}ufe$ Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg smallbreak loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

A Severe Cervical Spondylotic Myelopathy Patient Treated with Integrative Korean Medicine Including Acupuncture, Bee Venom Pharmacopuncture and Herbal Medicine: a case report

  • An, Da-young;Kim, Chae-eun;Han, Suzy;Kim, Mi-kyung;Yu, Jun-Sang;Sun, Seung-ho
    • Journal of Pharmacopuncture
    • /
    • v.25 no.2
    • /
    • pp.138-144
    • /
    • 2022
  • Cervical spondylotic myelopathy (CSM) is common in elderly people and severe CSM patients are recommended to receive surgery. However, in some cases, surgery may fail to improve the patients' symptoms. An 80-year-old man diagnosed with CSM complained of right hemiplegia and right arm and leg pain with the presence of a Foley catheter, despite treatment with laminectomy and laminoplasty. Acupuncture, bee venom pharmacopuncture, and herbal medicine were administered for 129 days. As a result, manual muscle testing (MMT) and the Modified Barthel Index (MBI) improved, the pain in his right arm and leg decreased, and he was able to urinate by himself. This case report implies that integrative Korean medicine (IKM) can be an option for patients suffering from muscular weakness resulting from myelopathy.