• Title/Summary/Keyword: Common Electrode

Search Result 172, Processing Time 0.041 seconds

Rapid Detection of Salmonella spp. by Antibody-Immobilized Piezoelectric Crystal Biosensor (고정화법을 달리하여 제조한 압전류적 항체 센서에 의한 Salmonella spp.의 신속 검출)

  • 박인선;김우연;김남수
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 1998
  • An improved antibody-coated sensor system based on quartz crystal microbalance was developed for the detection of Salmonella spp. An antibody against Salmonella common structural antigen was immobilized onto one gold electrode of the piezoelectric quartz crystal surface by various immobilization procedures. The best results in sensitivity and stability were obtained with the thin layers of protein A and 3,3'-dithiopropionimidate.2HCI(DTBP), a homobifunctional thiol-cleavable crosslinker. After the addition of a S. typhimurium suspension into a reaction cell with 0.1 M sodium phosphate buffer, pH 7.2, the resonant frequency owing to S. typhimurium adsorption decreased conspicuously. The antibody-immobilized crystals prepared by the gold-protein A complex formation and DTBP thiolation showed the frequency shifts of 80 and 283 Hz, respectively. The time required for maximum frequency shift was about 30~60 min. The antibody-coated crystal could be reused for 6~8 consecutive assays.

  • PDF

A Study on the Reduction of the High temperature misfiring in AC PDP (AC PDP의 고온오방전 개선에 관한 연구)

  • Park, Cha-Soo;Choi, Joon-Young;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-June;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1755-1758
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurancetest of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases lime lag in address discharge, and results m increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

Compensation of Addressing Time at High Temperature in ac PDP.

  • Choi, Joon-Young;An, Jung-Soo;Kim, Hun-Hee;Lee, Ho-Jun;Lee, Hea-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.164-170
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurance test of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases time lag in address discharge, and results in increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

Study on Novel Vertical Alignment liquid Crystal Device for Fast Response time and High Transmittance (빠른 응답속도와 고광효율을 위한 새로운 수직배향 액정디바이스에 대한 연구)

  • Cho, In-Young;Kim, Sung-Min;Kim, Woo-Il;Kim, Dae-Hyun;Kwon, Dong-Won;Son, Jong-Ho;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04a
    • /
    • pp.59-60
    • /
    • 2009
  • The conventional in-plane field driven-vertical alignment display (VA-IPS) shows fast response time but transmittance shows very low and operating voltage is very high. In this paper, we studies electro-optical properties of the novel in-plane field driven vertical alignment device which has two transistors on array part and common electrode on CF substrate with dielectric layer. The device shows fast response time and high transmittance.

  • PDF

A Study of the Fabrication and Enhancement of Film Bulk Acoustic Wave Resonator using Two-Step Deposition Method of Piezoelectric Layer (압전층의 2단 증착법을 이용한 체적 음향파 박막형 공진기의 제작과 성능향상에 관한 연구)

  • Park Sung-Hyun;Chu Soon-Nam;Lee Neung-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.308-314
    • /
    • 2005
  • The 2 GHz film bulk acoustic wave resonator(FBAR), one of the most necessary device of the next generation mobile communication system, consisted of solidly mounted resonator(SMR) structure using Brags reflector, was researched in this paper The FBAR applied SiO$_{2}$ and W had large difference of the acoustic impedance to reflector Al to electrode and ZnO to piezoelectric layer. Specially, the FBAR applied the two-step deposition method to improve the c-axis orientation and increase reproducibility of the fabrication device had good performance. The electrical properties of plasma such as impedance, resistance, reactance, $V_{pp},\;I{pp}$, VSWR and phase difference of voltage and current, was analyzed and measured by RF sensor with the variable experiment process factors such as gas ratio, RF power and base vacuum level about concerning the thickness, c-axis orientation, adhesion and roughness. The FBAR device about the optimum condition resulted reflection loss(S$_{11}$) of -17 dB, resonance frequency of 1.93 GHz, electric-mechanical coefficient(k$_{eff}$) of 2.38 $\%$ and Qualify factor of 580. It was seen better qualify than the common dielectric filter at present and expected on business to the filter device of 2 GHz bandwidth with the MMIC technology.

Measurement method of ground impedance for the grounding grid (접지그리드의 접지임피던스 측정 기법)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Choi, Young-Chul;Yoo, Jae-Duk;Beak, Young-Hwan;Kim, Dong-Seong;Shin, Hee-Kyung;Yoo, Yang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

Ultrasound-guided Pulsed Radiofrequency Lesioning of the Ulnar Nerve in a Patient with Cubital Tunnel Syndrome -A case report- (팔꿉굴증후군 환자에서 초음파를 이용한 척골신경의 박동성고 주파술의 경험 -증례보고-)

  • Ghil, Bo-Gyoung;Kil, Ho-Yeong
    • The Korean Journal of Pain
    • /
    • v.21 no.3
    • /
    • pp.224-228
    • /
    • 2008
  • Ulnar nerve compression in the cubital tunnel is a common entrapment syndrome of the upper limb. Pulsed radiofrequency lesioning (PRFL) has been reported as a treatment method for relieving neuropathic pain. Since the placement of the electrode in close proximity to a targeted nerve is very important for the success of PRFL, ultrasound seems to be well suited for this technique. A 36-year-old woman presented with complaints of numbness and pain on the medial aspect of the elbow and the pain radiated down to the $4^{th}$ and $5^{th}$ fingers for 10 years after she suffered an elbow contusion, we then scheduled this woman for the ultrasound guided PRFL of the ulanr nerve. The initial ultrasound examination demonstrated a swollen nerve, loss of the fascicular pattern and an increased cross sectional area of the ulnar nerve. After confirmation of the most swollen site of the nerve via ultrasound, two sessions of PRFL were performed. The postprocedural 10 cm visual analog scale score decreased from 8 to 1 after the two sessions of PRFL.

Impact of Upper Limb Joint Fluid Variation on Inflammatory Diseases Diagnosis

  • Hari, Krishnan G.;Ananda, Natarajan R.;Nanda, Anima
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2114-2117
    • /
    • 2014
  • Joint pain is generally a common disorder not only for the old aged people but also for the immunocompromised patients. The present proposed study reveals the presence of inflammatory diseases in joint generally diagnosed by removing synovial fluid and changes in the volume and composition are examined for the presence of WBC and crystals. This study implement a non-invasive approach to identify the changes in joint fluid by measuring the changes in electrical property of the synovial tissue under the influence of electrical current signal with frequency range between 100 kHz to 300 kHz. The response of tissue for the current signal was measured in terms of potential drop across the tissue. The hardware system design consists of input and output sections. The input section which applies current signal to upper limb joint region is made of ICL8038 function generator IC with amplifier and voltage to current converter. The output section picks voltage variation using metal surface electrode, amplifier, ADC, PIC microcontroller and LCD interface. 100 patient inclusive of normal and disease affected patients where examined for upper limb synovial fluid variation and inflammatory diseases were identified.

Development of a Virtual Frisch-Grid CZT Detector Based on the Array Structure

  • Kim, Younghak;Lee, Wonho
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Background: Cadmium zinc telluride (CZT) is a promising material because of a high detection efficiency, good energy resolution, and operability at room temperature. However, the cost of CZT dramatically increases as its size increases. In this study, to achieve a large effective volume with relatively low cost, an array structure comprised of individual virtual Frisch-grid CZT detectors was proposed. Materials and Methods: The prototype consisted of 2 × 2 CZTs, a holder, anode and cathode printed circuit boards (PCBs), and an application-specific integrated circuit (ASIC). CZTs were used and the non-contacting shielding electrode method was applied for virtual Frisch-grid effect. An ASIC was used, and the holder and the PCBs were fabricated. In the current system, because the CZTs formed a common cathode, a total of 5 channels were assigned for data processing. Results and Discussion: An experiment using 137Cs at room temperature was conducted for 10 minutes. Energy and timing information was acquired and the depth of interaction was calculated by the timing difference between the signals of both electrodes. Based on obtained three-dimensional position information, the energy correction was carried out, and as a result the energy spectra showed the improvements. In addition, a Compton image was reconstructed using the iterative method. Conclusion: The virtual Frisch-grid CZT detector based on the array structure was developed and the energy spectra and the Compton image were successfully acquired.

Hydrodynamic Modeling for Discharge Analysis in a Dielectric Medium with the Finite Element Method under Lightning Impulse

  • Lee, Ho-Young;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.397-401
    • /
    • 2011
  • The response of lightning impulse voltage was explored in dielectric liquids employing hydrodynamic modeling with three charge carriers using the finite element method. To understand the physical behavior of discharge phenomena in dielectric liquids, the response of step voltage has been extensively studied recently using numerical techniques. That of lightning impulse voltage, however, has rarely been investigated in technical literature. Therefore, in this paper, we tested impulse response with a tip-sphere electrode which is explained in IEC standard #60897 in detail. Electric field-dependent molecular ionization is a common term for the breakdown process, so two ionization factors were tested and compared for selecting a suitable coefficient with the lightning impulse voltage. To stabilize our numerical setup, the artificial diffusion technique was adopted, and finer mesh segmentation was generated along with the axial axis. We found that the velocity from the numerical result agrees with that from the experimental result on lightning impulse breakdown testing in the literature.