• Title/Summary/Keyword: Commercial fitting

Search Result 89, Processing Time 0.034 seconds

Practical Guide to X-ray Spectroscopic Data Analysis (X선 기반 분광광도계를 통해 얻은 데이터 분석의 기초)

  • Cho, Jae-Hyeon;Jo, Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.223-231
    • /
    • 2022
  • Spectroscopies are the most widely used for understanding the crystallographic, chemical, and physical aspects of materials; therefore, numerous commercial and non-commercial software have been introduced to help researchers better handling their spectroscopic data. However, not many researchers, especially early-stage ones, have a proper background knowledge on the choice of fitting functions and a technique for actual fitting, although the essence of such data analysis is peak fitting. In this regard, we present a practical guide for peak fitting for data analysis. We start with a basic-level theoretical background why and how a certain protocol for peak fitting works, followed by a step-by-step visualized demonstration how an actual fitting is performed. We expect that this contribution is sure to help many active researchers in the discipline of materials science better handle their spectroscopic data.

Development of Slim-Fit Pants Pattern for Obese Male Adolescents (비만 남자 청소년의 슬림핏 팬츠 패턴 개발)

  • Lim, Bo Yun;Kweon, Soo Ae;Kim, Jiyoung
    • Journal of Fashion Business
    • /
    • v.22 no.5
    • /
    • pp.96-112
    • /
    • 2018
  • This study developed the pants pattern, that improved appearance and gesture functions in clothes to resolve inconveniences in case of activities with being adequate in fitness of slim-fit pants for obese adolescents. The slim-fit pants pattern was developed through the fitting test after designing and making the pattern of the experimental clothing A(c/pu; 99/1%) with the primary commercial clothing as basic prototype, through the fitting test and implementation of the experimental clothing, modified and supplemented secondarily, and through the fitting test of the second experimental clothing, modified and supplemented tertiary. In terms of findings, first, as a result of analyzing the commercial slim-fit pants, it is interpreted to have projected an optical illusion, that appears to be slim due to being narrow in width of the front panel when observed from the front of the pants. Second, in the fitting test of the first experimental clothing, the prototype of commercial clothing was understood to have improved butt, crotch, waist and femoral regions. Third, pattern design of the second experimental clothing was allowed to decline abdominal pressure, in case of the sitting position, by making the crotch line in the front panel short and by handling it with a yoke belt, and was processed a difference between waist and hip circumference in the back panel, with a rubber band in the whole waist part. Fourth, in the gesture function test of the third experimental clothing, high evaluation was received in every item excluding the knee region.

Technical Note : Development of Electric Riding Machine for Cycle Fitting (단신 : 사이클 피팅을 위한 전동 승차 조절기 개발)

  • Bae, Jae-Hyuk;Choi, Jin-Seung;Kang, Dong-Won;Seo, Jeong-Woo;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.373-378
    • /
    • 2012
  • The purpose of this study was to develop an electric riding machine for cycle fitting to control riding posture easily, to measure frame size quantitatively, and to overcome disadvantages of the traditional systems. The electric riding machine consisted of actuator, load controller, and display & control unit. The actuator unit by BLDC(BrushLess Direct Current) motor drives the saddle height up and down, the crank forward and backward, the handlebar up and down, and the handlebar forward and backward. The load controller unit controls loads by Eddy current controller with electromagnet and aluminum circular plate. The display & control unit consisted of frame size controller and display panel which shows top tube length(485~663mm), head tube length(85~243mm), seat tube length(481~671mm), and seat tube angle($62.7{\sim}76.4^{\circ}$). The range of frame size control for developed electric riding machine did not have difference compared to traditional commercial systems, but quantitative and precise control with 0.1 mm length and $0.1^{\circ}$ angle was possible through digital measurement. Unlike traditional commercial systems, frame size control was possible during riding through motor driven method, thus fitting duration decreased. It is necessary for further improvement to have feedback from users. It is believed that developed electric riding machine can help to develop domestic fitting system.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Virtual Fitting Solutions for Digital Fashion in the Ubiquitous Environment (유비쿼터스 환경에서 디지털 패션을 위한 가상 피팅 서비스 솔루션)

  • Choi, Ja-Ryoung;Lim, Soon-Bum
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.299-306
    • /
    • 2010
  • According to development of Internet and computer graphics technology, Digital fashion technology makes virtual fitting service capable by reappearing of clothes in 3D. In this paper, We suggest that combined solution which you could use virtual fitting service with various device. For example, imaginary mirror(such as digital information display), pc, mobile in different situations such as store, internet shopping market, commercial. Users can experience imaginary mirror that is located in store or 3D virtual fitting service for digital fashion in internet shopping market, mobile application. In addition, We proposed the solution that user can send experienced virtual fitting service results to other person by image file form of MMS.

Implementation of a Body Weight Distribution Measurement System Applicable to Static Bicycle Fitting (정적 자전거 피팅에 적용 가능한 체중 분포 측정장치의 구현)

  • Yoon, Seon-ho;Kwon, Jun-hyuk;Kim, Cheong-worl
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.242-248
    • /
    • 2018
  • Bicycle fittings have been used to ride bicycles comfortably while minimizing non-traumatic injuries. To analyze the cause of non-traumatic injuries, it is necessary to measure the body weight distribution in various biking positions. In this study, a weight distribution measurement system was implemented by installing five weighable devices on the saddle, both pedals, and both handle grips of a bicycle. To measure the body weight applied through the saddle, the structure of a commercial seat post was modified and a load cell was installed inside. Weighable pedals and handle grips were designed using a 3D modeling program and fabricated by employing a 3D printer. The body weight distribution for ten bicycle riders was measured when the two pedals were aligned horizontally and vertically. Experimental results showed that the body weight distribution varied significantly depending on human body shape, even after the bicycle fitting was completed. The difference between the body weight measured by the proposed system and a commercial scale was less than 3 %.

A Basic Study of Pattern Alteration for People with Body Deformities -Focusing on the Brain Injured Handicapped- (특이 체형 패턴 보정을 위한 기초 연구 -뇌병변 장애인을 중심으로-)

  • Na Hyun-Shin
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.7 s.106
    • /
    • pp.121-132
    • /
    • 2006
  • The feeling of self-confidence, the sense of well-being and of social acceptance that comes from the wearing clothes that is functional, appropriate, and attractive, is important to all the people, but to those with physical limitations, it is much more important. Finding well-fitting clothing can be a big challenge for them. This study focus on the cut of present available ready-to-wear garments and commercial patterns giving better fit and greater comfort and satisfaction. Subjects were limited to the people with body deformities caused by the brain injury. This can also meet the needs of silver groups in the aging society under the terms of human values and human rights. This study is based on the questionaires and interviews to identify the problems of ready-to-wear or commercial patterns, purchasing behaviors, and the demand for the functional clothes. This study focused on following objectives; 1) to discover what the problems are which confront the people with body deformity, 2) to find the problems in ready-to-wear garments or commercial patterns, 3) to provide information of pattern alteration f3r people with body deformities. A major limitation to the study is that the subjects numbers are limited and the distribution is not even. For the future study, large database with wide varieties of age and fitting test are suggested.

Experimental Study for the Development of New Type Water Ejector (신형 수이젝터 개발을 위한 실험연구)

  • Mun, Soo-Bum;Choi, Hyun-Kue;Choi, Jae-Hyuk;Kwon, Hyung-Jung;Kim, Kyung-Keun;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.677-684
    • /
    • 2006
  • An ejector is a fluid transfer device to be used for mixing of fluids, maintaining vacuum, and overcoming a poor suction condition. To date, most ejectors have been made from the casting process. which is time-consuming and high-cost process. Therefore, a new production method of ejectors is desired if any. In this experimental study, we proposed a new type ejector manufactured from the commercial fitting materials and the welding process, which is equipped with an orifice type nozzle. The proposed ejector has a good integrity compared with the conventional ejector because the fittings have manufactured by forging and they have more strength than the casting materials. Furthermore we adopted a multi-opening orifice type nozzle for improving a suction capacity and compared with a single-opening orifice type nozzle. From the experimental results. we confirmed that the multi-opening nozzle had a food suction capacity than the single-opening nozzle and the proposed new type ejector showed higher vacuum than the conventional type ejector in non-load condition. These improved characteristics suggests that a new type ejector by using the commercial fittings opens the feasibility to be adopted in various industry fields and that the increased suction capacity can be achieved by altering the nozzle design of a conventional ejector.

The Performance Assessment of a Straight-Type Five-Hole Pressure Probe Using a Zone Partition and Two-Dimensional Curve-Fitting Functions (영역분할과 2차원 커브피팅 함수들을 이용하는 직선형 5공 압력프로브의 성능 평가)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.22-31
    • /
    • 2014
  • This paper introduced the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new velocity data reduction method using both a commercial two-dimensional curve-fitting program and the zone partition method of a calibration map was firstly introduced in this study. This new calibration method can be applied up to the wide flow angle of ${\pm}80^{\circ}$ despite of using a five-hole pressure probe because this data reduction method showed a comparatively good performance in calculating yaw and pitch angles from the calibration map.

Improvement of corrosion resistance and hardening the back ferrule surface by plasma treatment (Back ferrule 의 내식성과 체결시 기계적특성을 만족시키는 최적의 플라즈마 침질탄화공정조건의 확립)

  • Lee, In-Seop;Debnath, Sanket
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.179-180
    • /
    • 2012
  • Back ferrule is a circular ring shaped metallic object which is used for fastening, joining or reinforcement during the tube fitting as well as to prevent leakage. Therefore, during tube fitting the leading edge of the back ferrule should be sufficiently hard enough to prevent leakage. In our research, we concentrated the improvement of two major factors. Firstly, to improve the surface hardness of the back ferrule made by AISI 316 Stainless Steel. Secondly, the enhancement of corrosion resistance of back ferrule after plasma treatment. Initially, the corrosion resistance and hardness of the back ferrule (both commercial and without treated) was not good enough for tube fitting but after applying plasma treatment with suitable conditions on ferrule, we improved the corrosion resistance and hardness of the back ferrule dramatically.

  • PDF