• 제목/요약/키워드: Commercial Buildings

검색결과 446건 처리시간 0.03초

업무용 건물의 End-Use 전력 사용실태 분석 (Analysis of Electricity Use of Commercial Buildings by End-Use)

  • 박종진;이창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1150-1152
    • /
    • 1998
  • Recently, our electric industry confronts a structural change and high competiveness environment in the course of deregulation. Rapid growth in electricity demand, financial need for new power plant construction, and envionmental problems have led to search for more efficient energy production and energy conservation techmologies. Especially, residential and commercial buildings consumes 40% of electricity demands and building energies are increasing more and more in Korea. The purpose of this paper is to analyze the electricity use of commercial buildings by end-use. Also, we will use it as a basic informations of DSM potential evaluation and evaluation process based on different approach by sector and type of potential.

  • PDF

상업시설로 용도변경 된 도심지 단독주택의 외부 리모델링에 관한 연구-서울특별시 강남구 압구정동과 청담동을 중심으로- (A Study on the Exterior Remodeling for Using Commercial Facility of Housing in City)

  • 여준기;홍성우;최무혁
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.31-39
    • /
    • 2002
  • The purpose of this study is to examine the exterior remodeling examples of urban houses which have been changed to be mixed-use buildings with commercial use, and to guide the future exterior remodeling. Some of the research results are as follows: 1) Exterior remodeling of commercialized urban detached houses is focused on two-dimensional changes of exterior surface, rather than on three-dimensional changes of mass or shape. 2) Unlike commercial buildings generally relying on signboards to express their commercial nature, the exterior-renovated houses with commercial uses mainly rely on the image of whole building shape based on exterior materials and colors. 3) Installations of free-standing walls and double skins are preferred as exterior remodeling techniques, due to the structural limitation of exterior walls.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part I: FE model establishment and validations

  • Liu, X.;Wu, H.;Qu, Y.G.;Xu, Z.Y.;Sheng, J.H.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.381-396
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part I, finite element (FE) models establishment and validations for both the aircrafts and NPP buildings are performed. (i) Airbus A320 and A380 aircrafts are selected as the representative medium and large commercial aircrafts, and the corresponding fine FE models including the skin, beam, fuel and etc. are established. By comparing the numerically derived impact force time-histories with the existing published literatures, the rationality of aircrafts models is verified. (ii) Fine FE model of the Chinese Zhejiang Sanao NPP buildings is established, including the detailed structures and reinforcing arrangement of both the containment and auxiliary buildings. (iii) By numerically reproducing the existing 1/7.5 scaled aircraft model impact tests on steel plate reinforced concrete (SC) panels and assessing the impact process and velocity time-history of aircraft model, as well as the damage and the maximum deflection of SC panels, the applicability of the existing three concrete constitutive models (i.e., K&C, Winfrith and CSC) are evaluated and the superiority of Winfrith model for SC panels under deformable missile impact is verified. The present work can provide beneficial reference for the integral aircraft crash analyses and structural damage assessment in the following two parts of this paper.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part II: Structural damage and vibrations

  • Qu, Y.G.;Wu, H.;Xu, Z.Y.;Liu, X.;Dong, Z.F.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.397-416
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part II, based on the verified finite element (FE) models of aircrafts Airbus A320 and A380, as well as the NPP containment and auxiliary buildings in Part I of this paper, the whole collision process is reproduced numerically by adopting the coupled missile-target interaction approach with the finite element code LS-DYNA. The impact induced damage of NPP plant under four impact locations of containment (cylinder, air intake, conical roof and PCS water tank) and two impact locations of auxiliary buildings (exterior wall and roof of spent fuel pool room) are evaluated. Furthermore, by considering the inner structures in the containment and raft foundation of NPP, the structural vibration analyses are conducted under two impact locations (middle height of cylinder, main control room in the auxiliary buildings). It indicates that, within the discussed scenarios, NPP structures can withstand the impact of both two aircrafts, while the functionality of internal equipment on higher floors will be affected to some extent under impact induced vibrations, and A380 aircraft will cause more serious structural damage and vibrations than A320 aircraft. The present work can provide helpful references to assess the safety of the structures and inner equipment of NPP plant under commercial aircraft impact.

Applying Neural Networks to Model Monthly Energy Consumption of Commercial Buildings in Singapore(ICCAS2004)

  • Dong, Bing;Lee, Siew Eang;Sapar, Majid Hajid;Sun, Han Song
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1330-1333
    • /
    • 2004
  • The methodology for modeling building energy consumption is well established for energy saving calculation in the temperate zone both for performance-based energy retrofitting contracts and measurement and verification (M&V) projects. Mostly, statistical regression models based on utility bills and outdoor dry-bulb temperature have been applied to baseline monthly and annual whole building energy use. This paper presents the application of neural networks (NN) to model landlord energy consumption of commercial buildings in Singapore. Firstly, a brief background information on NN and its application on the building energy research is provided. Secondly, five commercial buildings with various characteristics were selected for case studies. Monthly mean outdoor dry-bulb temperature ($T_0$), Relative Humidity (RH) and Global Solar Radiation (GSR) are used as network inputs and the landlord monthly energy consumption of the same period is the output. Up to three years monthly data are taken as training data. A forecast has been made for another year for all the five buildings. The performance of the NN analysis was evaluated using coefficient of variance (CV). The results show that NNs is powerful at predicting annual landlord energy consumption with high accuracy.

  • PDF

강릉의 근대건축물에 관한 건축적 특성 조사연구 (An Investigation Study on the Architectural Characteristics of Modern Building at Gangneung)

  • 박문호;최장순
    • 한국농촌건축학회논문집
    • /
    • 제7권1호
    • /
    • pp.73-87
    • /
    • 2005
  • The purpose of this study is aimed at grasping the architectural characteristics of modern buildings in Gangneung from 1910's to 1970's. The results are as follows. 1) The commercial buildings are mostly unsymmetrical flat type and others except commercial buildings are mostly symmetrical flat type. 2)Up until the 1940's, staircases were located inner of building between the first and the second floor, however after the 1950's, they were separately located in one side of the building to ensure perpendicularly more space and easier mobility than before. 3)Windows were widely used in order to avoid monotonous wall elevation after 1950' s. 4)Striped decorations were put to use to decorate the front elevation of building. 5)Parapet which had decorative stripes to the top was generally used to hide roof.

  • PDF

Stack Effect Guidelines for Tall, Mega Tall and Super Tall Buildings

  • Simmonds, Peter;Zhu, Rui
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.323-330
    • /
    • 2013
  • The ASHRAE Technical Committee for Tall Buildings, TC 9.12, has defined a tall building as one whose height is greater than 300 feet (91m). Since the publication of the HVAC Design Guide for Tall Commercial Buildings in 2004, there were only about 300 buildings taller than 200 meters; this number has risen to 600 in 2010 and the prediction 765 buildings taller than 200 meters in 2012. There has also been an introduction of two new classes of tall buildings: ${\bullet}$ Mega tall, which are buildings taller than 300 m, and ${\bullet}$ Super tall, which are buildings taller than 600 m. The effect of ambient air temperature over the height of buildings, especially Mega tall and Super tall buildings. The ambient climatic conditions vary with altitude and these changes in ambient conditions can seriously affect load calculations and performance of super and mega tall buildings. This paper presents revised calculations for stack effect for Tall, Mega Tall and Super tall Buildings.

서울시 대가구 주거지역의 상업화·업무화와 상업지역의 주거화 현상의 고찰 (An Investigation of the Building-use Changes of Residential and Commercial Areas in the Land-used Superblocks in Seoul)

  • 전진부;양우현
    • 한국주거학회논문집
    • /
    • 제26권6호
    • /
    • pp.127-137
    • /
    • 2015
  • This investigation is to question as to whether and how much urban residential superblocks have changed the uses of facilities, as compared with original zoning plan. The difference between the original plan for 'land use' in 1960's and current 'building uses' has been examined on six superblocks in Seoul, and the reasons for change were analyzed. Investigation results are as follows: As the original urban planning was intended for use-purification by the subdivision of zones in a superblock through zoning, current buildings uses are different from the land-use. Commercial facilities are located in residential zone along community paths because of the necessity, and business buildings are placed on the appropriate-sized lots in the middle of residential blocks, due to the need of small and low-rent offices. Also, different types of residence have been built on convenient locations in commercial zone to meet various housing needs. In conclusion, the current zoning system plays a role of controling the volume of buildings rather than the use of land. Therefore, mixed use of land, not functional separation, becomes a natural phenomenon taken place in the contemporary cities, and it is high time to adopt a mixed-use zoning system.

사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석 (Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building)

  • 서병모;손정은;이광호
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

건축공사 공사실적자료 데이터베이스 활용방안 - 상업시설물을 중심으로 - (The Application of Actual Database for building construction - Focusing on Commercial building -)

  • 이성호;김태희;한충희;김선국
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2001년도 학술대회지
    • /
    • pp.428-433
    • /
    • 2001
  • 상업시설물은 주거용 건축물과 함께 가장 많이 건설되는 시설물이다. IMF 이후, 건설시장은 경기침체와 원가 상승으로 크게 위축되었다. 이에 따라, 건설업에도 정보 인프라의 활용에 의한 생산성 향상에 관한 연구가 요구되어졌고, 이러한 연구 중 하나가 공사실적자료 관리 및 활용에 관한 것이다. 상업시설물의 실적자료 데이터베이스를 구축하기 위해 데이터 베이스 요소 분석을 하였다. 상업시설물의 주요관리항목과 이용자별 요구정보를 분석하여, 수집양식을 작성하고 이를 데이터베이스화 하였다. 활용에 대한 방안 연구는 건설업 라이프싸이클에서 원가 및 자원 항목에 대해 제시하였다.

  • PDF