A Study on the Fire Scenarios according to Initial Fire Source Classification and Fire Statistics Investigation of Business & Sales Faciliteis (업무·판매시설의 화재통계조사 및 초기화원분류를 통한 화재시나리오에 관한 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.42-43
    • /
    • 2017
  • In Korea, The buildings are getting higher and bigger, and also the fire risk is getting increased. The PBD was introduced in 2009 for the fire safety of these buildings, but the study on making scenario based on actual case of fire is insufficient. Therefore on this study, it will conduct an experiment about initial fire classification and making fire scenario based on that actual fire statistic investigation classification of PBD buildings as official and commercial facilities.

  • PDF

Evaluation Method for Value Analysis in the Remodeling of Apartment Building (아파트 건축물의 리모델링 가치분석을 위한 평가방법)

  • Kang Soon-Kil;Um Chan-Yong;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.157-160
    • /
    • 2005
  • Recently remodelling has been popular with the consensus on the environment protection, resources saving, and regards on the cultural value of buildings. and the remodelling is considered as a useful tool for commercial and apartment buildings. But, in Korea, the remodelling has been introduced recently and there is few reserches on the evaluation methods for value analysis in the remodelling. This research deals with economical selection method among various alternatives for living environment upgrading of old buildings. Also, this reserch studied on the selection method for the architect among various remodelling plans considering cost, building life cycle, and user needs when the remodelling is selected as the most economical method.

  • PDF

Energy Performance Evaluation of VAV System through Various Operating Strategies in Office Buildings (VAV 시스템의 현장 운전방식에 따른 에너지 성능평가)

  • 서종욱;허정호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.184-193
    • /
    • 2004
  • The purpose of this study is to evaluate the performance of various control strategies in commercial buildings which have been operated by the variable air volume (VAV) system. Two buildings in Seoul were chosen for the field study. The one (D building) combined by LonWorks has the constant airflow of supply fan and the proportional control of VAV units (damper type). The other (S building) combined by DDC has the PI control mode of the supply fan and the floating control of VAV units (venturi type). In estimating thermal comfort and energy performance through control modes of PI, PID, and CAV in the supply fan, we could identify several energy efficient operating control strategies for the VAV system.

Development of the Centralized Monitoring and Control System for Absorption Chillier-heaters

  • Lee, Ji-Hyung;Ryu, Sang-Hun;Park, In-Wan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.66.2-66
    • /
    • 2001
  • Double-effect absorption chiller-heaters have been widely installed in large buildings and are also becoming popular in mid-sized commercial buildings. While much emphasis is Put on designing energy saving and efficient chiller-heaters, careful attention must also be given to the design of control systems for these devices. Currently, these devices are controlled by their own built-in controllers, such as relay based sequence controller or microprocessor based controller. But, because large buildings require multiple chiller-heaters, a centralized supervision and control system is necessary for the efficient monitoring, control, and operations management of these devices We have developed man-machine interface software that allows the implementation of such a system. This system will support increased reliability, more efficient building management operations, and reduced ...

  • PDF

A Study on the Evaluation of Building Exterior Design Applied to Repertory Grid Developmental Method - Focused on Small Exhibition Buildings - (레퍼토리 그리드 발전 수법을 적용한 건축물 외관 디자인 평가에 관한 연구 - 소규모 전시 건축물을 중심으로 -)

  • 윤갑근;정사희;이종영
    • Korean Institute of Interior Design Journal
    • /
    • no.26
    • /
    • pp.26-34
    • /
    • 2001
  • The problems with the small exhibition buildings such a small gallery and art center recently constructed did not make the characteristics of the place specifying and did not form a big flow in the line of urban connection. Also it was deficient in the image like a cultural space because of the commercial aspects of the individual buildings. According to this view, this study is to evaluate the exteriors of the small exhibition buildings that the public prefers on the psychological side as a design theory and then, it is to present the direction of desirable form constitution hereafter. In the design of the small exhibition buildings exterior that the public must prefers, the principles and techniques of constitution that operate are the most initiative as follows. As for the principles of unity in the constitution of the small exhibition buildings exterior that the public prefers, Eigen Value is 7.573 and the explanatory force takes 21.637% at the top and it plays a leading role. In the comparison of the appearance, it shows that it is a factor with the largest specific gravity. The next factors were grouped in good order: the balance, ornamental technique, change, shipping technique, rhythm, harmony, symbolic technique, area technique and adding technique. As a result, in the design of the small exhibition buildings exterior, the architects have to constitute the principles of balance, change, rhythm and harmony by most of the unity and the symbolic technique and form technique by most of the ornamental techniques harmoniously and have to give Identity like exhibition buildings.

  • PDF

A Case Analysis Utilization of Historical Buildings - Focused on Conversion-type Buildings - (역사적 건축물의 활용에 관한 사례분석 - 전용형 사례를 중심으로 -)

  • Park, Jong-Hye;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • This study aimed to present the possibilities that a variety of conversions can be made in terms of the spatial function through the situation analysis and in-depth case studies, focusing on the cases of the conversion of historic buildings. Literature analysis and case analysis technique were conducted as the research methods. For the literature analysis, the researcher selected 105 cases of conversion-type buildings by recombining and reanalyzing them to space functional changes; the SPSS PC+ 18.0 program was used as the analysis tool to conduct a frequency analysis and cross analysis. In-depth analysis was conducted to investigate the overview of the architecture, building history, spatial functional changes, space program, conservation value, and the conserved parts by selecting 9 cases in Korean and foreign countries that have been recently converted through literature analysis and the results of the study were as follows. 1) As a result of analyzing the changes in function, the highest percentage of the cases was conversion into the cultural function (63.8%). 2) There were cases for conversion into the commercial function, business function, accommodation function and educational function besides cultural function. 3) As a result of spatial program, the attempts to increase the utilization of the building generally by applying the complex space with more than two functions could be seen. 4) The buildings with historical and architectural value were conserved most of the outer wall and some portion of internal parts; the buildings with symbolic value were renovated largely, while preserving symbolic parts; and the buildings with practical value were renovated in a way that maintains the structural parts while changing the interior space to be suitable for their function.

District Energy Use Patterns and Potential Savings in the Built Environment: Case Study of Two Districts in Seoul, South Korea

  • Lee, Im Hack;Ahn, Yong Han;Park, Jinsoo;Kim, Shin Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.48-58
    • /
    • 2014
  • Energy efficiency is vital to improve energy security, environmental and social sustainability, and economic performance. Improved energy efficiency also mitigates climate change by lowering greenhouse gas (GHG) emissions. Buildings are the single largest industrial consumer of energy and are therefore key to understanding and analyzing energy consumption patterns and the opportunities for saving energy at the district level in urban environments. This study focused on two representative boroughs in the major metropolitan area of Seoul, South Korea as a case study: Gandong-gu, a typical residential district, and Jung-gu, a typical commercial district. The sources of the energy supplied to the boroughs were determined and consumption patterns in different industry sectors in Seoul used to identify current patterns of energy consumption. The study analyzed the energy consumption patterns for five different building categories and four different sectors in the building using a bottom-up energy modeling approach. Electricity and gas consumption patterns were recorded for different building categories and monthly ambient temperatures in the two boroughs. Finally, a logarithmic equation was developed to describe the correlation between commercial activity and cooling energy intensity in Jung-gu, the commercial district. Based on these results, recommendations are made regarding the current energy consumption patterns at the district level and government energy policies are suggested to reduce energy consumption and, hence, greenhouse gas emissions, in both commercial and residential buildings.

A Study on the Actual Construction Database Modeling and Application for Commercial Buildings (상업건축물의 공사칠적 데이터베이스(DB) 모델구축 밑 응용방안)

  • Kim Sun-Kuk;Lee Sung-Ho;Kim Tae-Hui;Joo Jin-Kyu
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.1 s.9
    • /
    • pp.83-90
    • /
    • 2002
  • Actual construction data are unsystematically handled and uselessly hoarded after completion of the project although actual construction data can be applied to the various works of the future projects. Many researches have been carried out by several engineers and scholars of construction firms and research institutes, but the level of the application is not plausible yet. The objective of this paper is to propose a web-based data model and application system for commercial buildings in order to enhance the usability of the actual construction data on line. The principal factors of commercial building project data and the user$^{\circ}{\phi}s$ requirements in various areas, such as planning, design, procurement and construction and so on are analyzed to implement the database structure of the proposed system. The application of resource Information focused on cost, manpower, equipment is included in the system, which is expected to enhances the usability of actual database application system compared with other researches proposed so far.

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.3
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.

A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement (SD500철근 커플러 이음의 편익/비용분석에 관한 연구)

  • Kim, Jae-Yeob;Kwon, Yeo-Wool;Kim, Jun-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.