• Title/Summary/Keyword: Combustion gases toxicity

Search Result 36, Processing Time 0.024 seconds

Comparison of combustion gas release for FRP and seat cover materials to the Furnace temperature (연소온도 조건에 따른 FRP 및 시트커버 내장재의 연소가스 발생량 비교)

  • Lee, Duck-Hee;Jung, Woo-Sung;Lee, Cheul-Kyu;Yu, Mun-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1527-1532
    • /
    • 2007
  • We have evaluated the toxicity of interior materials for the railway passenger car by checking the release of $CO_2$, CO, NOx, SO2, HCl, HF, HBr, HCN. The NOx is one of the most effective for the determination of Toxic Index R value. It is generally known that the mechanism of thermal NOx generation without the Interior Material nitrogen source. This study started from the idea to check the NOx difference according to the furnace temperature. But from the results, it was revealed that NOx is not so sensitive for the furnace temperature in case of solid burning. Other gases such as HCN, CO were more changeable to the furnace Temp. We reported the test result as for toxicity index r(x).

  • PDF

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors (다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발)

  • Lee, Kwangjae;Lee, Youn-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

A Study on MDA Analysis & blood chemical test for Mouse which were exposed HF Gases from Fire (화재로 인한 불화수소(HF)가스에 노출된 마우스의 혈액생화학분석 및 MDA분석을 통한 세포손상에 관한 연구)

  • Cho, Nam-Wook;Oh, Eun-Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.58-66
    • /
    • 2013
  • Among the risks which can be faced with fire, combustion toxicity is a significant influence on the survival. Fire toxicity researches have been limited generally on the lethal aspects. In this study, HF gas which can be generated from fire, and also found in general industrial site was used for analysis. Blood analysis and biochemistry analysis performed to find internal demage of experimental animals which were used for measuring average activity stopping time from Animal test(KS F2271: Gas hazard test). In addition, Using the malondialdehyde analysis, indicators of oxidative damage, we had quantitative analysis to target lymphocyte for measuring the oxidative damage caused by toxic substances.

A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method (가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구)

  • Shim, Ji-Hun;Lee, Jae-Geol;Han, Kyoung-Ho;Kim, Ju-Wan;Song, Seok-Hun;Jo, Hyung-Won;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.519-524
    • /
    • 2022
  • Domestic building finishing materials are being evaluated according to KS F 2271 standards according to the notification of the Ministry of Land, Infrastructure and Transport, and this test is evaluated using laboratory animals. In this study, experiments were conducted on highly combustible organic insulation materials such as EPS, urethane, and phenolic foam. The purpose of this study was to analyze the cause of the behavioral suspension of the experimental mice by measuring the average behavioral suspension time of the mice caused by the harmful gas generated when these three types of insulation materials were burned. FTIR analysis and smoke density experiment were performed as a cause analysis method for the behavioral suspension of mice, and the experimental results were analyzed by dividing the causes of behavioral suspension into suffocation by particulate matter and toxic inhalation by gaseous substances. As a result of the test, urethane was evaluated as the most harmful insulation material, and as a result of FTIR analysis and smoke density test as a cause analysis for the gas toxicity test results, it is judged that the behavioral stop of the rats by suffocation is higher than the effect of toxic inhalation. This study is a basic study on the cause analysis of harmful gases, and it will be necessary to prepare the toxicity basis and analyze various materials and gases.

Evaluation of Combustion Gas for Carbon Oxide of Wood Coated with Bis-(dialkylaminoalkyl) Phosphinic Acids Additives

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.65-72
    • /
    • 2016
  • This study examined the generation of combustion toxic gases of pinus rigida specimens processed with bis-(dimethylaminomethyl) phosphinic acid (DMDAP), bis-(diethylaminomethyl) phosphinic acid (DEDAP), and bis-(dibutylaminomethyl) phosphinic acid (DBDAP). Each pinus rigida plate was coated three times with 15 wt.% flame retardants in an aqueous solution. The specimens were then dried at room temperature. The production of combustion toxic gases was investigated using a cone calorimeter (ISO 5660-1). The first time to peak mass loss rate ($1^{st}-TMLR_{peak}$) processed with the chemical additives decreased to 5.9 from 41.2% compared with the unprocessed specimen. The second time to the peak mass loss rate ($2^{nd}-TMLR_{peak}$) for the processed specimens was decreased 1.8% for DMDAP and 5.3% for DBDAP and increased 1.8% for DEDAP. The peak carbon monoxide ($CO_{peak}$) production was 1.5 to 2.0 times higher than that of the unprocessed plate. The peak carbon dioxide ($CO_{2peak}$) production was reduced 0.01 times for DMDAP and increased 1.15 to 1.19 times for DEDAP and DBDAP compared with the unprocessed specimens. In particular, the oxygen concentration was much higher than 15%, which can be fatal to humans and the resulting hazard can be eliminated. Overall, the combustion toxicity of flammable gas were increased partially by the chemical additives compared with those of the unprocessed plate.

Experimental Study on the Toxicity Characteristics of Non-Class 1E Cables according to Accelerated Deterioration (가속열화에 따른 비안전등급 케이블의 독성특성에 관한 실험적 연구)

  • Jang, Eun-Hui;Kim, Min-Ho;Lee, Min Chul;Lee, Sang-Kyu;Moon, Young-Seob
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.105-113
    • /
    • 2019
  • This study investigates the toxicity characteristics of two Non-Class 1E Cables (For security reasons, we refer to company A and company B) used in nuclear power plants according to the accelerated deterioration period. In accordance with NES 713 test equipment and standards, tests were carried out on non-aged cables and the cables subjected to 20- and 40-year-accelerated-deterioration; each of the cables was further classified into sheath and insulation. The test results showed that the toxicity indices of 20- and 40-year-accelerated-aged cables were higher than those for the non-aged cables, and 20-year-aged cables of both A and B companies showed the highest toxicity indices. This is attributed to the extensive emissions of carbon monoxide and halide gases such as hydrogen chloride and hydrogen bromide. Furthermore, to analyze the toxicity indices of sheath and insulation in detail, the US Department of Defense standard (MIL-DTL) was applied to determine whether the Toxicity index (T.I.) allowance was exceeded, and the results showed that the insulating materials emitted considerably more than the allowable limit.