• Title/Summary/Keyword: Combustion Test Facility

Search Result 124, Processing Time 0.024 seconds

Low Pressure Combustion Tests for Technology Demonstration Model of 75 tonf Thrust Chamber (75톤급 액체로켓엔진 연소기 저압연소시험)

  • Kim, Jong-Gyu;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Mun-Ki;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.10-13
    • /
    • 2010
  • Low pressure combustion tests for TDM(Technology Demonstration Model) of 75 tonf thrust chamber were performed. It has design chamber pressure of 60 bar, propellant mass flow rate of 243.6 kg/s. Due to the limitation of the current firing test facility in Korea, the combustion tests were conducted to verify the operation and the combustion performance at low pressure condition (30 bar, 121.8 kg/s). All the tests had been successfully executed without the damage of the hardware. These test results can be used as fundamental data to predict the combustion performance at design point condition for 75 tonf thrust chamber.

  • PDF

Firing Test of KSR-III Rocket Propulsion System (KSR-III 로켓 추진기관 연소시험)

  • Kang Sun-Il;Kwon Oh-Sung;Lee Jung-Ho;Kim Young-Han;Ha Seong-Up;Cho Kwang-Rae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.126-135
    • /
    • 2004
  • The KSR-III rocket developed by KARI is the first rocket vehicle which is adopting the liquid propellant rocket engine system in Korea and its flight test was successfully done last year, KSR-III is a sounding rocket class launch vehicle, but there is a sense to accomplish design, manufacture, performance test and finally its flight test by domestic technology. In this paper, the authors are intended to introduce the multi-purpose test facility(PTA-II Test Facility) which is constructed for the variety of tests on KSR-III feeding system(single component tests, verification tests, cold flow tests and combustion tests) and its firing test results.

Development of Low NOx Combustor for 55kw Class Micro Gasturbine (55kW급 마이크로터빈용 저공해 연소기 개발)

  • Kim Hyung-Mo;Park Young-Il;Park Poo-Min;Yang Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.318-321
    • /
    • 2005
  • The design and performance test of a low NOx gas turbine combustor to be used in 55kW class micro-gasturbine engine was performed in KARI's combustion test facility. The combustor is reverse flow-can type for easy installation of injector and other parts and LNG is used as fuel. The performance targets are $99.5\%$ combustion efficiency, less 10ppm NOx, $30\%$ patten factor and $4\%$ pressure loss. Most of the performances required are satisfied.

  • PDF

Internal Flow Aerodynamic Test of a Mach 5 Scramjet Engine (마하 5 스크램젯 엔진의 내부 유동 공력 시험)

  • Yang, In-Young;Lee, Yang-Ji;Kim, Young-Moon;Lee, Kyung-Jae;Kang, Sang-Hoon;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.584-587
    • /
    • 2011
  • An internal flow aerodynamic test was performed for a Mach 5 scramjet engine. The test was done without fuel injection, as a preliminary test for the combustion test. Test engine is an engineering model with intake cross-section of $70mm{\times}200mm$ and total length of 1.7m. Test facility is a blowdown-type, high enthalpy, hypersonic facility. 19 pressures were measured through the holes on the model surface along the engine internal flow passage. It was found that the facility start is possible, and also supersonic flow is maintained inside the engine.

  • PDF

The Power-pack combustion test and Evaluatin of Technology Demonstraion Model for Sataged Combustion Cycle Engine (다단연소엔진 기술검증시제 파워팩 시험 평가)

  • Jeon, Junsu;Kim, Seungryong;Kim, Sunghyuk;Kim, Seunghan;Kim, Chaehyoung;Seo, Daeban;So, Younseok;Woo, Seongphil;Lee, Kwangjin;Yi, Seungjae;Lee, Jungho;Im, Jihyuk;Yu, Byungil;Cho, Namkyung;Hwang, Changhwan;Han, Yeoungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.104-107
    • /
    • 2017
  • The power-pack combustion test of technology demonstration model(TDM0) for 9 tonf-class staged combustion cycle engine development was conducted in the Upper-stage Engine Test Facility(UETF) of Naro Space Center. The power-pack model of TDM0 was composed of a pre-burner, a turbo-pump and propellant supply systems without a main combustor. In the power-pack combustion test, we confirmed the linked working condition and verified the main functional variation of the power-pack for the engine system test.

  • PDF

Combined De-NOx Process with $NH_3$ SCR and Non-thermal Plasma Process for Removing NOx and Soot from Diesel Exhaust Gases

  • Chung, Kyung-Yul;Song, Young-Hoon;Oh, Sang-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.657-665
    • /
    • 2003
  • Combined De-NOx Process in which $NH_3$ SCR (Selective Catalytic Reduction) and non-thermal Plasma Process are simultaneously used, has been investigated with a pilot test facility. The pilot test facility treats the combustion flue gases exhausted from a diesel engine that generates 240 kW of electrical power. Test results show that up to 80 % of NOx (NO and NO2) can be removed at 100 - $200^{\circ}C$. None of conventional De-NOx techniques works under such low temperature range. In addition to NOx. the Pilot test results show that soot can be simultaneously treated with the present non-thermal plasma technique. The present pilot test shows that the electrical power consumption to operate the non-thermal plasma reactor is equivalent to 3 - 4 % of the electrical power generated by the diesel engine.

1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility (물 분무를 이용한 연소가스 냉각 1차원 해석)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The cooling of hot exhaust gas is an important issue for the construction of combustor test facility. Water spray is an effective method for exhaust gas cooling due to its large latent heat in process of evaporation. In this study, 1-D analysis has been performed based on continuity, energy conservation, and saturated vapor property to understand water spray cooling of combustion gas. In the exhaust duct of combustor test facility, the injected water decreases combustion gas temperature, and evaporates in the combustion gas. However, some of the injected water is collected in the sump due to condensation. The evaporation of water helps combustion gas cooling, but causes pressure increase inside the exhaust duct due to increase of vapor pressure. These phenomena has been analyzed by 1-D modeling in this study. From 1-D analysis, the adequate mass flow rate of water spray to cool combustion gas and to avoid excessive pressure rise inside the exhaust duct has been decided.

LOx/kerosene Sub-scale LRE Firing Test Facility (액체산소/케로신 소형로켓엔진 연소시험설비)

  • Kim Seung-Han;Lim Byoung-Jik;Han Yeoung-Min;Seol Woo-Seok;Lee Soo-Yong;Moon Il-Yoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.166-169
    • /
    • 2004
  • This paper describes the design, installation and certification activity of a combustion test facility of subscale thrust chambers propelled by pressure-fed liquid oxygen and kerosene, and suggests major key issues considered at each development stage of the facility

  • PDF

Combustion Characteristics of the Slinger Combustor (슬링거 연소기의 연소특성)

  • 이강엽;이동훈;최성만;박정배;박영일;김형모;한영민
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.173-178
    • /
    • 2003
  • The study was performed to understand combustion characteristics of the slinger combustor. Liquid fuel is discharged radially outwards through injection holes drilled in the high speed rotating shaft. We observed atomizing characteristics with variation of fuel nozzle rotating speed by using PDPA system. The mean drop diameter highly depends on fuel nozzle rotating speed. In KARI combustion test facility, Ignition and combustion tests were performed by using real scale combustor. In the test results, ignition and combustion efficiency were increased according to increasing fuel nozzle rotating speed. The measured radial temperature distribution at the combustor exit shows stable and fairly good distribution.

  • PDF

Performance Test of 5MW Gas Turbine Engine Combustor (5MW 발전용 가스터빈 엔진 연소기 성능시험)

  • Park, Poo-Min;Kim, Hyung-Mo;Choi, Young-Ho;Yang, Soo-Seok;Chon, Mu-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • Performance test of 5MW class gasturbine combustor was carried out at combustor test facility of KARI(Korea Aerospace Research Institute). The combustor is dry low NOx type premixed combustor and fuel is natural gas. The characteristics of combustor were measured including emission, pressure pulsation and exit temperature distribution. Optimum operation point of combustor was found by changing parameters like fuel ratio between pilot and main burner. The test result showed that the combustor performance is sufficient to satisfy the gasturbine system requirement.

  • PDF