• 제목/요약/키워드: Combustible material

검색결과 121건 처리시간 0.021초

원전구조물 적용 마감재의 국내 연소시험방법 조사연구 (Study of Testing Methods for Combustible Properties of Finishing Materials Applied into Nuclear Power Plants)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.60-61
    • /
    • 2018
  • Finishing materials are very important to restrain fire spread from a compartment to another in a fire situation. Therefore, the evaluation of combustible properties for the combustible material is essential to apply finishing materials into a generic buillding or s special occupancy structure. In this study, the testing methods for evaluation of combustible performance of finishing materials of domestic were surveyed in order to prepare the guideline of application of finishing materials in nulear power plant.

  • PDF

접촉연소식 가스 센서의 검지특성 (Detecting Characteristics of Catalytic Combustible Gas Sensor)

  • 박찬원;원창섭;유영한;안형근;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

실규모 실험에 의한 고체가연물의 화재특성 연구 (A Study on Fire Characteristics of Solid Combustible Materials Based on Real Scale Fire Test)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.62-68
    • /
    • 2011
  • 본 연구는 고체가연물의 초기 점화 및 화재성장과정에서의 발열량을 정량적으로 측정하고 가연물에 따른 화재성장특성 파악하고자 한다. 실험에 적용된 고체가연물은 단일/이중 목재크립, 단일/이중 쿠션, 카페트/목재크립이며 화재발달 단계에서 화재성장특성을 시간 제곱 화재성장 시나리오와 비교분석하고 고체가 연물의 화재성장 계수를 정량화 하였다. 고체가연물의 연소과정에서 소모되는 연료의 질량과 방출되는 총열에너지 개념을 이용하여 가연물의 평균 유효연소율을 평가하였으며 환기 및 화재조건의 영향을 분석하여 화재해석시 화재시나리오를 설정하는데 있어서 실질적인 정보를 제공하고자 한다.

산화마그네슘 및 재유화형 분말수지를 사용한 시멘트계 불연단열재의 단열특성 (Insulation Property of Cement-based Non-combustible Inorganic Insulation Using MgO and Redispersible Polymer Powder)

  • 손배근;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.120-121
    • /
    • 2021
  • The organic insulation material has excellent thermal insulation property, but it is difficult to expect fire stability, and semi inorganic insulation only delays combustible hour but it is difficult to expect fire stability. In this study, thermal insulation property of cement-based non-combustible inorganic insulation using cement and non combustible materials and redispersible polymer powder was studied. As a result of the experiment, the thermal insulation property decreased as the use of redispersible polymer powder increased, but the heat insulation property improved when using the appropriate amount.

  • PDF

CLC를 활용한 공동주택 불연성능 외벽몰딩 개발 (Development of Non-flammable exterior design Molding using Cellular Light-weight Concrete)

  • 권해원;공민호;이창용;정갑철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.54-55
    • /
    • 2020
  • Recently, "The rules on the standards of evacuation and fire protection of buildings" require that non-burnable materials such as non-combustible and semi-non-combustible materials be used as the materials applied to the building's exterior walls, but styrofoam, which is a combustible material, has been applied a lot and became a social issue. In this study, we developed a non-combustible outer wall molding to secure construction and economic feasibility and free expression using CLC(CLC: Cellular Light-weight Concrete).

  • PDF

가연성 천연고분자 분체의 훈소에 관한 연구 (Smouldering Combustion of Combustible Natural Polymer Dust Layer)

  • 김홍
    • 한국안전학회지
    • /
    • 제5권1호
    • /
    • pp.7-18
    • /
    • 1990
  • This study measured the smouldering temperature of dust layer for various combustible natural polymer material by practical apparatus. The dust layer was either put on the preheated plate of constant temperature, or formed with cylinderical metal sleeve of various diameters and depths at room temperature and then heated up to a pre-determined smouldering temperature. Plots of arrival times versus smouldering temperature were made to compare the smouldering characteristics with kinds of dusts. The natural polymer material was divided into theree groups by characteristics of smouldering mechanism. This groups are cellulose group, lipide group and glucose group.

  • PDF

경량 폴리머 콘크리트의 난연성 및 동결융해 저항성 (Incombustibility and Freezing-Thawing Resistance of Lightweight Polymer Concrete)

  • 채경희;최예환;연규석;이윤수;주명기
    • 한국농공학회지
    • /
    • 제45권1호
    • /
    • pp.45-54
    • /
    • 2003
  • The effects of binder content and silica sand content on the durability characteristics of lightweight polymer concretes are examined. As a result, the flame lingering times using unsaturated polyester resin and non-combustible polyester resin were 60∼120 and 0∼4 seconds respectively, and the combustion lengths were 9∼11 mm and 0∼3 mm, respectively. Thus it is believed that the lightweight polymer concrete was incombustible and the light weight polymer concrete in which non-combustible material was added was perfectly non-combustible. The percent of original mass of lightweight polymer concrete, according to the freezing-thawing experiment, was below 0.3 %, which was much less than that of cement concrete. The pluse velocity, for the case of the binder content 28 %, showed the minimum decreasing rate for the lightweight polymer concrete with silica sand content of 50 %. The higher the binder content, the greater the durability. That is much higher than other material and believed that the freezing-thawing was suppressed by a low absorption.

생활폐기물매립장에서의 RDF 적응가능성에 대한 연구 (Study on applicability of RDF in Municipal Waste Landfill Site)

  • 김정권
    • 한국환경과학회지
    • /
    • 제18권10호
    • /
    • pp.1181-1187
    • /
    • 2009
  • Results for application of RDF(Refuse Derived Fuel) to selected wastes in metropolitan and small and medium cities are as follows. The physical characteristics of waste are paper, plastic, food waste, and so on. The proximate analysis in P city showed 20.2% of moisture, 71% of combustible material, and 8.8% of ash on annual average. That in G city showed 31.6% of moisture, 59.5% of combustible material, and 8.9% of ash. Ultimate analysis in P city showed 52.04% of carbon, 7.02% of hydrogen, 28.80% of oxygen, 0.66% of nitrogen, and 0.09% of sulfur. Heating value was 3,363 kcal/kg. Ultimate analysis in G city showed 50.85% of carbon, 6.56% of hydrogen, 29.86% of oxygen, 0.79% of nitrogen, and 0.12% of sulfur. Heating value in the G city was somewhat lower than that in the P city with 2,632 kcal/kg. Thus, application of RDF in metropolitan city was more effective than that in small and medium cities. Heating value in mixture for the P city was lower than that in waste of the volume rate waste charge system alone by 143 kcal/kg. In proximate analysis, moisture, and combustible material were likely to be more adequate to RDF.

평탄형 접촉 연소식 가스 센서의 특성 (Characteristics of Catalytic Combustible Gas Sensor Based on Planar Technology)

  • 김영복;노효섭;박진성
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.812-817
    • /
    • 2008
  • A catalytic combustible sensor for LPG/LNG detection was fabricated on $Al_2O_3$ substrate using planar technology. The catalysts of Pd and Pt were added to ${\alpha}$- and ${\gamma}-Al_2O_3$ powders. The mixture of Pt, Pd and $Al_2O_3$ were homogenized by using a three roll mixer. TCR characteristics of Pt heater were optimized with the heat treatment temperature. Sensing properties were investigated as a function of the microstructure of $Al_2O_3$, the gas concentration and the variation of input voltage. ${\alpha}-Al_2O_3$ sintered at 500 $^{\circ}C$ is more suitable as LPG/LNG sensor due to good grain shape and size distribution of about 300 nm than that of ${\gamma}-Al_2O_3$ which is in irregular shape and with a particle size of 5-30 ${\mu}m$. The sensor has shown maximum output voltage of 14 mV for 1000 ppm $C_4H_{10}$ and 3.8 mV for 1000 ppm $CH_4$ at 5.0 V input voltage.

연소시 생성된 CO가스의 고찰을 통한 인명피해 최소화 방안에 관한 연구 (A Study on the ways to minimize Casualties through a consideration of the CO gas generated during combustion)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.133-140
    • /
    • 2013
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.