• 제목/요약/키워드: Combined wedge

검색결과 49건 처리시간 0.028초

Effects of Combined Wedge on Angle and Moment of Ankle and Knee Joint During Gait in Patients With Genu Varus

  • Yang, Hae Sun;Choi, Houng Sik
    • 국제물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.1025-1030
    • /
    • 2016
  • The purpose of this study was to investigate the effects of combined wedge on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion of foot for genu varus among adult men during gait. This study was carried out with 10 adult men for genu varus in a motion analysis laboratory in J university. The subjects of the experiment were measured above 5cm width between the knees on contact of both medial malleolus of ankle while standing. The width of their knees in neutral position was measured without the inversion or eversion of the subtalar joint by the investigator. The subjects of the experiment were ten who were conducted randomly for standard insole, insole with $10^{\circ}$ lateral on rear foot wedge, insole at $10^{\circ}$lateral on rear foot and $5^{\circ}$ medial on fore foot wedge. Before and after intervention, changes on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion were measured. In order to compare analyses among groups; repeated one-way ANOVA and $Scheff{\acute{e}}$ post hoc test were used. As a result, combined wedge group was significantly decreased compared to control wedge group in terms of knee varus angle in mid-stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of ankle eversion moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of knee adduction moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge in terms of center of pressure excursion in whole stance(p<.05). The results of this study suggest that combined wedge for genu varus decreased ankle eversion moment and knee adduction moment upon center of pressure excursion. We hypothesize that combined wedge may also be effective in the protection excessive ankle pronation.

Freiberg병에서 시행한 Weil 절골술 (Weil Osteotomy for Freiberg's Disease)

  • 이화성;권순용;김동욱;정진화
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.217-222
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the result of combined Weil and dorsal closing wedge osteotomy for Freiberg's disease. Materials and Methods: We performed combined Weil and dorsal closing wedge osteotomy of the second metatarsal under the diagnosis of Freiberg's disease in 7 patients, 7 feet (2 male and 5 female). The mean age at the time of operation was 29 years and the mean follow-up period was 31 months. Patients had no trauma history and no combined deformity of the foot. The surgical results were evaluated by VAS and weight bearing radiographs in antero-posterior and oblique projection. Results: According to Smillie staging system, there were 1 of stage II, 2 of stage III and 4 of stage IV patients. The osteotomy site was united at 8 weeks and the second metatarsal was shortened in length of average 2.8 mm. Remodeling of the metatarsal head was observed at 24 months. The mean VAS was decreased from 8.2 points preoperatively to 2.7 points at follow-up. And average range of motion of second metatarso-phalangeal joint was increased from 30o preoperatively to 45o at follow-up. There was no transfer metatarsalgia or arthritis of the metatarsal head during follow-up. Conclusion: Combined Weil and dorsal closing wedge osteotomy of the metatarsal appears to be an effective procedure for the treatment of Freiberg's disease with a view to shortening of metatarsal length and elevation of metatarsal head.

반도체 Sub-Fab 용 웨지 마운트 레벨러(Wdge Mount Leveler)의 마찰과 응력에 관한 연구 (A study on friction and stress analysis of wedge mount leveler in Semi-Conductor Sub-Fab)

  • 민경호;송기혁;홍광표
    • Design & Manufacturing
    • /
    • 제11권2호
    • /
    • pp.25-28
    • /
    • 2017
  • Semiconductor equipment manufacturers desire to enhance efficiency of Sub Fab to increase semiconductor productivity. For this reason, Sub Fab equipment manufacturers are developing Integrated System that combined modules with multiple facilities. Integrated System is required to apply Mount Leveler of Wedge Type in compliance with weight increase compared with existing single equipment and product shape change. This thesis analyzes main design variables of components of Wedge Mount Leveler and carries out structure analysis using ANSYS, finite element analysis program Analysis shows that main design variables of components of Wedge Mount Leveler has self-locking condition by friction force of Wedge and adjusting bolt. Each friction force hinges upon Wedge angle and Friction Coefficient of contact surface and upon the thread angle and Friction Coefficient of contact surface. Also, as a result of carrying out structure analysis of Wedge Mount Leveler, deflection and stress appears in different depending on the height of the level.

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

The Most Massive Active Galactic Nuclei at 1

  • Jun, Hyunsung
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.44.2-44.2
    • /
    • 2017
  • We obtained near-infrared spectra of 26 SDSS quasars at 0.7${\sim}10^{{\wedge}{10}}M{\odot}$ to critically examine the systematic effects involved with their mass estimations. We find that active galactic nuclei (AGNs) heavier than $10^{{\wedge}{10}}M{\odot}$ often display double-peaked $H{\alpha}$ emission, extremely broad FeII complex emission around MgII, and highly blueshifted and broadened CIV emission. The weight of this evidence, combined with previous studies, cautions against the use of MBH values based on any emission line with a width over 8000 km/s. Also, the MBH estimations are not positively biased along the presence of ionized narrow line outflows, anisotropic radiation, or the use of line FWHM instead of ${\sigma}$ for our sample, and unbiased with variability, scatter in broad line equivalent width, or obscuration for general type-1 quasars. Removing the systematically uncertain MBH values, ${\sim}10^{{\wedge}{10}}M{\odot}$ BHs in 1${\sim}10^{{\wedge}{9.5}}M{\odot}$ BHs, although current observations support they are intrinsically most massive, and overmassive to the host's bulge mass.

  • PDF

실내역학 실험을 통한 쐐기형 제거식 쏘일네일링 공법의 적용성 평가 (An Estimation of Wedge Type Removable Soil Nailing System Using by Laboratory Tests)

  • 박시삼;한연진;허성준;윤명준;김홍택;박주석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1330-1333
    • /
    • 2009
  • The soil nailing method had used in variable construction field because of construction convenience and reinforcement effect. Especially, the removal soil nailing method is useful support system in vertical excavation. In this study, to develop the wedge type removable soil nailing method for improvement of the removal soil nailing method. Because of the reinforcement materials is most important in soil nailing method, to evaluate the mechanical characteristics during laboratory strength test in this study. To conduct bond strength test of deformed bar combined with a wedged screw inside plastic fixed socket for evaluate the strength characteristics of wedge type removable soil nailing method and evaluate the strength characteristics of fixed socket based on laboratory tests.

  • PDF

앵커볼트의 내력평가에 관한 실험적 연구 (Strength of Anchors under Load Applied Angles)

  • 김성용;한덕전;신창훈
    • 한국방재학회 논문집
    • /
    • 제5권1호
    • /
    • pp.69-76
    • /
    • 2005
  • 본 연구는 익스팬션(고하중 앵커와 웨지앵커)의 내력평가 하기 위한 실험적 연구이다. 하중조건은 인발, 전단 및 인발과 전단의 조합하중이다. 고하중 앵커와 웨지 앵커는 국내산 앵커를 사용하였으며, 무근콘크리트에 매입하였다. 앵커 파괴 및 콘크리트 파괴모드에 따른 기존의 앵커 설계식를 연구하였으며, 실험결과를 인발 및 전단내력의 상호작용에 관한 여러 모델들과 비교 분석하였다. 연구결과 다음과 같은 결론을 얻었다. 조합하중 작용 시 힘의 상호작용은 타원형 상호관계가 가장 적합한 것으로 판단된다.

도시하수슬러지의 농축과 탈수 : 1차와 2차슬러지의 분리 및 혼합처리특성비교 (Thickening and Dewatering of Municipal Wastewater Sludge : Separate and Combined Treatment of Primary and Secondary Sludge)

  • 이진우;최훈창;최정동;정경영;전석주;권수열;안영호
    • 대한환경공학회지
    • /
    • 제27권1호
    • /
    • pp.93-100
    • /
    • 2005
  • 본 연구는 1차슬러지와 생물학적 영양소제거 슬러지의 처리에 있어서 분리 및 혼합처리에 대한 농축과 탈수특성을 조사하였다. 슬러지의 탈수를 위해서는 고분자 폴리머, 증기주입 및 초음파처리등의 슬러지 개량방법을 이용하여 슬러지의 개량특성을 분석하였고, 비저항계수측정법과 Wedge zone simulator 그리고 원심분리를 이용하여 탈수특성을 분석하였다. 농축실험결과 1차슬러지와 생물학적 2차슬러지를 분리농축하는 것이 바람직한 것으로 나타났으며, 특히 3.5%이상의 고농도 1차슬러지의 경우는 농축단계에서 상징수의 고액분리는 부정적이었다. 농축된 슬러지의 개량에 있어서는 폴리머 주입, 증기처리 및 초음파처리 등의 개랑법중에서 폴리머를 주입한 경우가 가장 우수한 탈수성을 나타내었다. 1차와 2차 및 혼합슬러지의 최적 폴리머 주입조건은 건조고형물 기준으로 각각 0.26%, 0.43% 및 0.38%이었다. 농축슬러지의 탈수실험에서는 1차와 2차슬러지를 혼합하여 처리하는 것이 고액분리측면에서나 반류수의 수질측면에서 보다 효과적으로 나타났다. 여과포를 이용하는 탈수방식은 폴리머의 사용이 필수적이었으나 이 경우 2차슬러지의 단독탈수는 효과가 없었다. 원심탈수 방법은 가장 우수한 탈수효율을 보였으며, 이때 폴리머의 주입으로 탈수케익의 고형물함량을 조금 더 향상시킬 수 있었다. 이상의 실험결과에 근거하여 반류수의 수질특성과 고형물회수를 고려한 합리적인 슬러지 처리공정을 제안하였다.

폐과오종의 외과적 치료 (Surgical Treatment of Pulmonary Hamartoma)

  • 김웅한;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • 제27권3호
    • /
    • pp.215-220
    • /
    • 1994
  • From Jan. 1981 to Dec. 1993, 24 cases of pulmonary hamartoma were experienced sugically at the Department of Thoracic Surgery, College of Medicine, Seoul National University. They consisted of 11 females and 13 males. The age distribution was 24 years to 71 years with a mean age of 49 years. They included 3 cases of endobronchial hamartoma, and 21 cases of pulmonary parenchymal hamartoma. Fifty eight percent of patients [14/24] were asymptomatic. One patient had a multiple pulmonary parenchymal hamartoma, and 1 patient also had combined lung cancer. The operative procedures were 9[37.5%] wedge resections, 5[20.8%] lobectomies, 3[12.5%] enucleations, 3[12.5%] segmental resections, 2[8.3%] bilobectomies, 1[4.2%] lobectomy and segmentectomy, and 1[4.2%] lobectomy, wedge resection, and enucleation. All of the operative results were excellent and without complication.

  • PDF

다양한 습식식각법을 이용한 (100), (110), (111) Si tip의 제작 (Fabrication of (100), (110), (111) Si Tips using Various Wet Etching Method)

  • 박흥우;주병권;고창기;홍순관;오명환;김철주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1250-1253
    • /
    • 1994
  • (100), (110) and (111) Si wafers are etched by isotropic etching method, anisotropic etching method using KOH etchant and EPW etchant and combined two-step etching method to compare the results. Isotopic etching method is effective in fabrication of wedge-shaped tips, especially (110) Si. Anisotropic etching method of (100) Si using EPW etchant can fabricate sharp cone-shaped tips and isotropic etching after anisotropic etching of (100) Si can fabricate wedge-shaped tips.

  • PDF