• Title/Summary/Keyword: Combined wedge

Search Result 47, Processing Time 0.037 seconds

Effects of Combined Wedge on Angle and Moment of Ankle and Knee Joint During Gait in Patients With Genu Varus

  • Yang, Hae Sun;Choi, Houng Sik
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1025-1030
    • /
    • 2016
  • The purpose of this study was to investigate the effects of combined wedge on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion of foot for genu varus among adult men during gait. This study was carried out with 10 adult men for genu varus in a motion analysis laboratory in J university. The subjects of the experiment were measured above 5cm width between the knees on contact of both medial malleolus of ankle while standing. The width of their knees in neutral position was measured without the inversion or eversion of the subtalar joint by the investigator. The subjects of the experiment were ten who were conducted randomly for standard insole, insole with $10^{\circ}$ lateral on rear foot wedge, insole at $10^{\circ}$lateral on rear foot and $5^{\circ}$ medial on fore foot wedge. Before and after intervention, changes on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion were measured. In order to compare analyses among groups; repeated one-way ANOVA and $Scheff{\acute{e}}$ post hoc test were used. As a result, combined wedge group was significantly decreased compared to control wedge group in terms of knee varus angle in mid-stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of ankle eversion moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of knee adduction moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge in terms of center of pressure excursion in whole stance(p<.05). The results of this study suggest that combined wedge for genu varus decreased ankle eversion moment and knee adduction moment upon center of pressure excursion. We hypothesize that combined wedge may also be effective in the protection excessive ankle pronation.

Weil Osteotomy for Freiberg's Disease (Freiberg병에서 시행한 Weil 절골술)

  • Lee, Hwa-Sung;Kwon, Soon-Yong;Kim, Dong-Wook;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.4
    • /
    • pp.217-222
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the result of combined Weil and dorsal closing wedge osteotomy for Freiberg's disease. Materials and Methods: We performed combined Weil and dorsal closing wedge osteotomy of the second metatarsal under the diagnosis of Freiberg's disease in 7 patients, 7 feet (2 male and 5 female). The mean age at the time of operation was 29 years and the mean follow-up period was 31 months. Patients had no trauma history and no combined deformity of the foot. The surgical results were evaluated by VAS and weight bearing radiographs in antero-posterior and oblique projection. Results: According to Smillie staging system, there were 1 of stage II, 2 of stage III and 4 of stage IV patients. The osteotomy site was united at 8 weeks and the second metatarsal was shortened in length of average 2.8 mm. Remodeling of the metatarsal head was observed at 24 months. The mean VAS was decreased from 8.2 points preoperatively to 2.7 points at follow-up. And average range of motion of second metatarso-phalangeal joint was increased from 30o preoperatively to 45o at follow-up. There was no transfer metatarsalgia or arthritis of the metatarsal head during follow-up. Conclusion: Combined Weil and dorsal closing wedge osteotomy of the metatarsal appears to be an effective procedure for the treatment of Freiberg's disease with a view to shortening of metatarsal length and elevation of metatarsal head.

A study on friction and stress analysis of wedge mount leveler in Semi-Conductor Sub-Fab (반도체 Sub-Fab 용 웨지 마운트 레벨러(Wdge Mount Leveler)의 마찰과 응력에 관한 연구)

  • Min, Kyung-Ho;Song, Ki-Hyeok;Hong, Kwang-Pyo
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.25-28
    • /
    • 2017
  • Semiconductor equipment manufacturers desire to enhance efficiency of Sub Fab to increase semiconductor productivity. For this reason, Sub Fab equipment manufacturers are developing Integrated System that combined modules with multiple facilities. Integrated System is required to apply Mount Leveler of Wedge Type in compliance with weight increase compared with existing single equipment and product shape change. This thesis analyzes main design variables of components of Wedge Mount Leveler and carries out structure analysis using ANSYS, finite element analysis program Analysis shows that main design variables of components of Wedge Mount Leveler has self-locking condition by friction force of Wedge and adjusting bolt. Each friction force hinges upon Wedge angle and Friction Coefficient of contact surface and upon the thread angle and Friction Coefficient of contact surface. Also, as a result of carrying out structure analysis of Wedge Mount Leveler, deflection and stress appears in different depending on the height of the level.

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

The Most Massive Active Galactic Nuclei at 1

  • Jun, Hyunsung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.44.2-44.2
    • /
    • 2017
  • We obtained near-infrared spectra of 26 SDSS quasars at 0.7${\sim}10^{{\wedge}{10}}M{\odot}$ to critically examine the systematic effects involved with their mass estimations. We find that active galactic nuclei (AGNs) heavier than $10^{{\wedge}{10}}M{\odot}$ often display double-peaked $H{\alpha}$ emission, extremely broad FeII complex emission around MgII, and highly blueshifted and broadened CIV emission. The weight of this evidence, combined with previous studies, cautions against the use of MBH values based on any emission line with a width over 8000 km/s. Also, the MBH estimations are not positively biased along the presence of ionized narrow line outflows, anisotropic radiation, or the use of line FWHM instead of ${\sigma}$ for our sample, and unbiased with variability, scatter in broad line equivalent width, or obscuration for general type-1 quasars. Removing the systematically uncertain MBH values, ${\sim}10^{{\wedge}{10}}M{\odot}$ BHs in 1${\sim}10^{{\wedge}{9.5}}M{\odot}$ BHs, although current observations support they are intrinsically most massive, and overmassive to the host's bulge mass.

  • PDF

An Estimation of Wedge Type Removable Soil Nailing System Using by Laboratory Tests (실내역학 실험을 통한 쐐기형 제거식 쏘일네일링 공법의 적용성 평가)

  • Park, Si-Sam;Han, Yeon-Jin;Heo, Seong-Jun;Yoon, Myung-June;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1330-1333
    • /
    • 2009
  • The soil nailing method had used in variable construction field because of construction convenience and reinforcement effect. Especially, the removal soil nailing method is useful support system in vertical excavation. In this study, to develop the wedge type removable soil nailing method for improvement of the removal soil nailing method. Because of the reinforcement materials is most important in soil nailing method, to evaluate the mechanical characteristics during laboratory strength test in this study. To conduct bond strength test of deformed bar combined with a wedged screw inside plastic fixed socket for evaluate the strength characteristics of wedge type removable soil nailing method and evaluate the strength characteristics of fixed socket based on laboratory tests.

  • PDF

Strength of Anchors under Load Applied Angles (앵커볼트의 내력평가에 관한 실험적 연구)

  • Kim, Sung-Yong;Han, Duck-Jeon;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.1 s.16
    • /
    • pp.69-76
    • /
    • 2005
  • The pull-out capacity of expansion anchor(heavy duty anchor and wedge anchor) was studied experimentally in this paper. Loading conditions included tension, shear, and combined tension and shear. The heavy duty anchor and wedge anchor were manufactured in domestic and installed In plain concrete. The failure mode of steel and concrete were studied carefully for the analytical formula of the anchorage design and the experimental data were compared with different models for the interaction of tension and shear capacities. Based on the research, the following conclusion may be drawn : The interaction of forces is well-described by an elliptical interaction relationship.

Thickening and Dewatering of Municipal Wastewater Sludge : Separate and Combined Treatment of Primary and Secondary Sludge (도시하수슬러지의 농축과 탈수 : 1차와 2차슬러지의 분리 및 혼합처리특성비교)

  • Lee, Jin-Woo;Choi, Hoon-Chang;Choi, Jeong-Dong;Jung, Gyung-Yeung;Jun, Seok-Ju;Kwon, Soo-Yul;Ahn, Young-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.93-100
    • /
    • 2005
  • Comparative thickening and dewatering characteristics of municipal wastewater sludge were investigated in terms of separated and combined treatment of primary and secondary BNR sludge. Also, various conditioning methods such as cation polymer addition, steam and ultrasonication treatment were examined to improve dewaterability of sludge. The dewaterability was measured by using specific resistant test, wedge zone simulator and centrifuge. The result of the sludge thickening test revealed that separated thickening was better in terms of solids recovery and supernatant quality. Particularly, the thickening of primary sludge with high solids (about 3.5% TS) showed very poor solid separation. The addition of cation polymer showed better conditioning characteristic for dewatering and the optimal polymer dosage was 0.26% for primary sludge, 0.43% for secondary sludge and 0.38% for combined sludge. Contrary to the result of the thickening, the dewatering test revealed that dewatering of the combined sludge is better than that of separated sludge, representing better solids separation and filtrate quality. The polymer addition was essential to improve dewaterability in filter (belt) press type dewatering but it was inefficient for the dewatering of secondary sludge only. The centrifuge type dewatering showed better performance and the dewaterability was slightly improved when the polymer was added. Based on the results of this research a sustainable sludge treatment process, particularly in terms of the recycle water quality and solids recovery, was proposed.

Surgical Treatment of Pulmonary Hamartoma (폐과오종의 외과적 치료)

  • Kim, Ung-Han;Seong, Suk-Hwan;Kim, Ju-Hyeon
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.215-220
    • /
    • 1994
  • From Jan. 1981 to Dec. 1993, 24 cases of pulmonary hamartoma were experienced sugically at the Department of Thoracic Surgery, College of Medicine, Seoul National University. They consisted of 11 females and 13 males. The age distribution was 24 years to 71 years with a mean age of 49 years. They included 3 cases of endobronchial hamartoma, and 21 cases of pulmonary parenchymal hamartoma. Fifty eight percent of patients [14/24] were asymptomatic. One patient had a multiple pulmonary parenchymal hamartoma, and 1 patient also had combined lung cancer. The operative procedures were 9[37.5%] wedge resections, 5[20.8%] lobectomies, 3[12.5%] enucleations, 3[12.5%] segmental resections, 2[8.3%] bilobectomies, 1[4.2%] lobectomy and segmentectomy, and 1[4.2%] lobectomy, wedge resection, and enucleation. All of the operative results were excellent and without complication.

  • PDF

Fabrication of (100), (110), (111) Si Tips using Various Wet Etching Method (다양한 습식식각법을 이용한 (100), (110), (111) Si tip의 제작)

  • Park, Heung-Woo;Ju, Byeong-Kwon;Ko, Chang-Gi;Hong, Soon-Kwan;Oh, Myoung-Hwan;Kim, Chui-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1250-1253
    • /
    • 1994
  • (100), (110) and (111) Si wafers are etched by isotropic etching method, anisotropic etching method using KOH etchant and EPW etchant and combined two-step etching method to compare the results. Isotopic etching method is effective in fabrication of wedge-shaped tips, especially (110) Si. Anisotropic etching method of (100) Si using EPW etchant can fabricate sharp cone-shaped tips and isotropic etching after anisotropic etching of (100) Si can fabricate wedge-shaped tips.

  • PDF