• Title/Summary/Keyword: Combined point

Search Result 1,040, Processing Time 0.025 seconds

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A Study on the Stability Boundaries for Single Layer Latticed Domes and Arch under Combined Loads (조합하중를 받는 단층 래티스 돔과 아치의 안정경계에 관한 연구)

  • Han, Sang-Eul;Lee, Sang-Ju;Lee, Kap-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.3 s.13
    • /
    • pp.103-109
    • /
    • 2004
  • The lowest load when the equilibrium condition becomes to be unstable is defined as the buckling load. The primary objective of this paper is to be analyse stability boundaries for star dome under combined loads and is to investigate the iteration diagram under the independent loading parameter. In numerical procedure of the geometrically nonlinear problems, Arc Length Method and Newton-Raphson iteration method is used to find accurate critical point(bifurcation point and limit point). In this paper independent loading vector is combined as proportional value and star dome was used as numerical analysis model to find stability boundary among load parameters and many other models as multi-star dome and arch were studied. Through this study we can find the type of buckling mode and the value of buckling load.

  • PDF

The Flow Characteristics of Parallel Plane Jets Using Particle Image Velocimetry Technique (I) - Unventilated Jet - (PIV기법을 이용한 병렬 평면제트의 유동특성 (I) - 유입이 제한된 제트 -)

  • Kim, Dong-Keon;Yoon, Soon-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.302-310
    • /
    • 2003
  • Experiments were conducted to show the characteristics of the flow on unventilated parallel plane jets. Measurements of mean velocity components and turbulent intensities were carried out with a particle image velocimetry to investigate the flow field generated by the air issued from two identical plane parallel nozzles and mixed with the ambient air. The measurements range of these experiments were Reynolds number of 5300 based on the nozzle width and the cases of nozzle-to-nozzle distance were four times. six times and eight times the width of the nozzle. Results show that a recirculation zone with a sub-atmospheric static pressure was bounded by the inner shear layers of the individual jets and the nozzles plate. The positions. where maximum value of mean turbulent intensities and mean turbulent kinetic energy show, were at the same position with the merging point. The spread of jets in the merging region increases more rapidly than that of Jets in the converging and the combined region. As nozzle-to-nozzle distances were increased. it was shown that merging and combined lengths were shorter.

Multi-Point Dieless Sheet Forming Technology Combined with Fluid forming (유체성형과 결합한 다점 무금형 판재 성형기술)

  • 박종우;홍예선;양승훈
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.58-61
    • /
    • 2002
  • A new concept of dieless sheet forming technology is proposed in this study to overcome the drawback of conventional dieless forming technology. For this purpose, dual points contact of the conventional punch system, which is a primary cause of surface defects, is replaced to single point contact using technology combined with fluid forming. It is expected that the advanced system may lead to easy displacement control of multi-punch elements, reducing surface defects, and increasing decision and forming limits. The reduced number of punch elements also saves the cost of the equipment. In addition, the new technology can be utilized for deep drawing as well as two- or three-dimensional curved surface forming, and thereby become multi-functional and multi-purpose differently from the conventional technology.

  • PDF

Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems (345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석)

  • 정채균;이종범;강지원
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.

Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems (혼합송전계통에서 재폐로 시행시 개폐과전압 해석)

  • Lim, Kwang-Sik;Lee, Jong-Boem;Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

A Combined Bearing Arrangement for High Damping Spindle Systems (고감쇠 주축 시스템을 위한 베어링의 복합배열에 관한 연구)

  • Lee, C.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.139-145
    • /
    • 1996
  • The machining accuracy and performance is largely influenced by the static, dynamic and thermal characteristics of spindle systems in machine tools, because the spindle system is a intermedium for cutting force from tool and machine powef from motor. Large cutting force and power are transmitted by bearing with a point or line contact. So, the spindle system is the static and dynamic weakest point in machine structure. For improvement of static stiffness of spindle system can be changed design parameters, such as diameter of spindle, stiffness of bearing and bearing span. But for dynamic stiffness, the change of the design parameters are not useful. In this paper, the combined bearing arrangement is suggested for high damping spindle system. The combined bearing arrangement is composed of tandem double back to back arrangement type ball bearins and a high damping hydrostatic bearing. The variation of static deflection and amplitude in first natural frequency is evaluated with the location of hydrostatic bearing between front and rear ball bearing. The optimized location of hydrostatic bearing for high static and dynamic stiffness is determined rapidly and exactly using the mode shape and transfer function of spindle. The calculation of damping effect on vibration by unbalance of grinding wheel and pulley in optimized spindle system is carried out to verify the validity of the combined bearing arrangement. Finally, the simulation of grinding process show that the surface roughness of workpiece with high damping spindle system is 60% better than with ball bearing spindle system.

  • PDF

Comparison of the Effect in ROM Increase and Pain Reduction on Stretching During Ultrasound Treatment in Patients With Frozen Shoulder (동결견 환자의 초음파치료 시 신장여부에 따른 관절가동범위 회복과 통증감소 효과 비교)

  • Yang, Hoe-Song
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.129-137
    • /
    • 2003
  • A single subject experimental design (alternating treatment design) was used to compare the effects of only ultrasound and ultrasound combined with stretching of the joint capsule on the ROM increase and pain reduction in patients with frozen shoulder. Two subjects were included in each group. In the only ultrasound treatment sessions, ultrasound was applied at the pain point of the shoulder joint in supine position. In the ultrasound combined with stretching treatment sessions, ultrasound was applied at the pain point of the shoulder joint positioned in external rotation and abduction in sitting position. Only ultrasound treatment and ultrasound combined with stretching treatment were alternately performed on each patient. Pain and disability was measured by shoulder pain and disability index (SPADI), and range of motion (ROM) was measured by scratch test. The results of this study showed that ultrasound combined with stretching treatment were more effective than only ultrasound treatment in ROM increase and pain reduction. However, disability score was not significantly different.

  • PDF

The runoff characteristics of non-point source to urban stream during rainfall (강우 시 도시 하천으로의 비점오염원 유출특성)

  • Park, Woon-Ji;Kim, Dong-Oog;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.83-89
    • /
    • 2007
  • We studied runoff characteristics of combined sewer overflows in a city while it was raining. The event mean concentration (EMC) of biochemical oxygen demand (BOD), chemical oxygen demand ($COD_{Cr}$), suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) in one of the combined sewer sites in Chuncheon was 63.5-211.6 mg/L, 114.9-523.8 mg/L, 70.3-436.4 mg/L, 6.4-33.0 mg/L, and 1.09-6.81 mg/L, respectively. In another combined sewer, the EMC of BOD, COD, SS, TN, and TP was 42.1-131.4 mg/L, 107.7-256.5 mg/L, 33.7-221.1 mg/L, 7.9-26.4 mg/L, and 1.16-3.91 mg/L, respectively. The ratio of the cumulative pollutant mass and the cumulative discharged volume determined using all parameters (BOD, $COD_{Cr}$, SS, TN, and TP) was over 1.0, which shows the first flush effect. Relationships between flow and loadings of BOD, $COD_{Cr}$, SS, TN, and TP were 0.90, 0.89, 0.88, 0.89, 0.92, respectively. Although the size of two areas was almost same, pollutant concentration and loading were different because of the amount of rainfall, rainfall intensity and basin area.

  • PDF