• Title/Summary/Keyword: Combined heat and power plant

Search Result 137, Processing Time 0.03 seconds

The Properties of Supper Flowing Concrete using Class C Fly Ash (C급 플라이애쉬를 사용한 초유동 콘크리트 특성)

  • Won, Cheol;Kwon, Yeong-Ho;Kim, Dong-Seok;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.276-282
    • /
    • 1996
  • This study dealt with the properties for fly ash of combined heat power plant and application for concrete industry. For this purpose, fly ash of ulsan combined heat power plant was analyzed for physical and chemical properties and tested the properties of the super flowing concrete. As results of fly ash, contents of SiO2 and Al2O3 in the fly ash of Ulsan were less than those of thermal power plant(Boryung), but contents of CaO were ten times as much as those of Boryung. In order to satisfy the properties of the Super Flowing Concrete using class C fly ash, mixing conditions were determined the optimum water-binder(w/b), volume ratio of fine aggregates(Sr) and coarse aggregates(Gv).

  • PDF

A Daily Optimal Operation Scheduling of Total Cogeneration System Operating by Combined Heat Power Plant and District Heat Devices (복합화력발전설비와 지역난방설비가 연계된 종합열병합발전시스템의 일간 최적운전계획 수립)

  • Jung, Ji-Hoon;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.183-186
    • /
    • 2001
  • This paper describes the optimal operation scheduling of total cogeneration system which is interconnected with combined heat power plant of utility and district heat devices. The numerical modeling about the cogeneration system and the auxiliary thermal energy devices are established and simulation is carried out by LINDO program in order to minimize the operation cost under the national viewpoint. The results reveal that the established numerical modeling and the operation strategy can be effectively applied to the total cogeneration systems to reduce the energy cost.

  • PDF

Life Cycle Assessment for the Business Activities of Green Company -2. Mass Balance and Environmental Improvement (녹색기업의 사업활동 전 과정에 대한 환경성 평가 -2. 물질수지 및 환경개선)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.425-433
    • /
    • 2013
  • A mass balance of process was calculated by using the analysis of basic unit and environmental assessment of all the processes of Busan fashion color industry cooperative that operates a combined heat and power plant and a bio treatment plant. The mass balance for the combined heat and power plant was done, based on boiler and water treatment processes while each unit reactor was used for the bio treatment plant. From the results above, a resource recycle network, a treatment flowchart for food waste water/wastewater treatment and a carbon reduction program were established.

Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating (냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kim, Tong-Seop;Kim, Jae-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

A Scheme of Introducing Class C Fly Ash to the Korean industrial Standard (C급 플라이애쉬에 대한 KS규준 도입방안)

  • 이상수;권영호;안재현;김무한;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.129-135
    • /
    • 1997
  • Recently, discarding of reuse of fly ashes produced from combined heat power plant of thermal power plant as a by-product causes several problems. Esepecially, the fly ash from Ulsan Pertrochemical Serviec Co, classified as class C is the first by-product to be reused or discarded. For the reuse of the class C fly ash, it is necessary to prepare and provide domestic specifications because there is no specifications on the fly ash of class C from combined heat power plant. Therefore, this study dealt with a scheme of introducing class C fly ash to the korean industrial standard.

  • PDF

The thermodynamic efficiency characteristics of combined cogeneration system of 120MW (120MW급 열병합 복합발전시스템의 열역학적 효율 특성)

  • Choi, Myoungjin;Kim, Hongjoo;Kim, Byeongheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.29-36
    • /
    • 2017
  • In this study, acombined cogeneration power plant produced two types of thermal energy and electric or mechanical power in a single process. The performance of each component of the gas turbine-combined cogeneration system was expressed as a function of the fuel consumption of the entire system, and the heat and electricity performance of each component. The entire system consisted of two gas turbines in the upper system, and two heat recovery steam generators (HRSG), a steam turbine, and two district heat exchangers in the lower system. In the gas turbine combined cogeneration system, the performance test after 10,000 hours of operation time, which is subject to an ASME PTC 46 performance test, was carried out by the installation of various experimental facilities. The performance of the overall output and power plant efficiency was also analyzed. Based on the performance test data, the test results were compared to confirm the change in performance. This study performed thermodynamic system analysis of gas turbines, heat recovery steam generators, and steam turbines to obtain the theoretical results. A comparison was made between the theoretical and actual values of the total heat generation value of the entire system and the heat released to the atmosphere, as well as the theoretical and actual efficiencies of the electrical output and thermal output. The test results for the performance characteristics of the gas turbine combined cogeneration power plant were compared with the thermodynamic efficiency characteristics and an error of 0.3% was found.

Feasibility of Combined Heat and Power Plant based on Fuel Cells using Biogas from Macroalgal Biomass (거대조류 바이오매스로부터 생산된 바이오가스를 사용하는 연료전지 기반 열병합발전의 타당성 검토)

  • Liu, Jay
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.357-364
    • /
    • 2018
  • Studies on the production of biogas from third generation biomass, such as micro- and macroalgae, have been conducted through experiments of various scales. In this paper, we investigated the feasibility of commercialization of integrated combined heat and power (CHP) production using biogas derived from macroalgae, i.e., seaweed biomass. For this purpose, an integrated CHP plant of industrial scale, consisting of solid oxide fuel cells, gas turbine and organic Rankine cycle, was designed and simulated using a commercial process simulator. The cost of each equipment in the plant was estimated through the calculated heat and mass balances from simulation and then the techno-economic analysis was performed. The designed integrated CHP process produces 68.4 MW of power using $36ton\;h^{-1}$ of biogas from $62.5ton\;h^{-1}$ (dry basis) of brown algae. Based on these results, various scenarios were evaluated economically and the levelized electricity cost (LEC) was calculated. When the lifetime of SOFC is 5 years and its stack price is $$225kW^{-1}$, the LEC was 12.26 ¢ $kWh^{-1}$, which is comparable to the conventional fixed power generation.

Thermodynamic analysis of a combined gas turbine power plant with a solid oxide fuel cell for marine applications

  • Welaya, Yousri M.A.;Mosleh, M.;Ammar, Nader R.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.4
    • /
    • pp.529-545
    • /
    • 2013
  • Strong restrictions on emissions from marine power plants (particularly $SO_x$, $NO_x$) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and gas turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. It includes a study of a heat-recovery system for 18 MW SOFC fuelled by natural gas, to provide the electric power demand onboard commercial vessels. Feasible heat-recovery systems are investigated, taking into account different operating conditions of the combined system. Two types of SOFC are considered, tubular and planar SOFCs, operated with either natural gas or hydrogen fuels. This paper includes a detailed thermodynamic analysis for the combined system. Mass and energy balances are performed, not only for the whole plant but also for each individual component, in order to evaluate the thermal efficiency of the combined cycle. In addition, the effect of using natural gas as a fuel on the fuel cell voltage and performance is investigated. It is found that a high overall efficiency approaching 70% may be achieved with an optimum configuration using SOFC system under pressure. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

Study of fuel cell CHP-technology on electricity generation sector using LEAP-model (LEAP 모형을 이용한 연료전지 열병합발전설비 도입에 따른 온실가스배출저감 잠재량 분석)

  • Shin, Seung-Bok;Jun, Soo-Young;Song, Ho-Jun;Park, Jong-Jin;Maken, Sanjeev;Park, Jin-Won
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.230-238
    • /
    • 2009
  • We study about small gas engine and fuel cell CHP (Combined Heat and Power) as the technologies for energy conservation and $CO_2$ emissions reduction. Korea government plans to use them in near future. This study quantitatively analyzed energy consumption and $CO_2$ emissions reduction potential of small CHP instead of existing electric power plant (coal steam, combined cycle and oil steam) using LEAP (Long-range Energy Alternative Planning system) as energy-economic model. Three future scenarios are discussed. In every scenario similar condition for each CHP is used. Alternative scenario I: about 6.34% reduction in $CO_2$ emissions is observed in 2019 due to increase in amount of gas engine CHP and fuel cell CHP while coal use in thermoelectric power plant is almost stagnant. In alternative scenario II: a small 0.8% increase in $CO_2$ emission is observed in 2019 keeping conditions similar to alternative scenario I but using natural gas in combined cycle power plant instead of coal. During alternative scenario II overall $CO_2$ emission reduction is observed in 2019 due to added heat production from CHP. Alternative scenario III: about 0.8% reduction in $CO_2$ emissions is observed in 2019 using similar CHP as AS I and AS II. Here coal and oil are used in thermoelectric power plant but the quantity of oil and coal is almost constant for next decade.

Analysis of the $CO_2$ emission amount and characteristics of combined heat and power plants in industrial complex by using the fuel analysis method (연료분석 방법을 적용한 산업단지 열병합발전소 이산화탄소 배출량 및 배출특성분석)

  • Kang, Seok-Hun;Chung, Dae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1243-1248
    • /
    • 2008
  • $CO_2$ emission amount and characteristics of combined heat and power (CHP) plant in industrial complex of Korea is evaluated by using the fuel analysis method. Fuel analysis methods of several foreign countries and developed one which is developed considering the operation characteristics of the surveyed CHP plants are used. The operation data is surveyed for all of the CHP plants in industrial complex and is composed of fuel consumption amount, generation, sale and efficiency of heat and electricity, condensed steam enthalpy, and etc of the each CHP.

  • PDF