• 제목/요약/키워드: Combined Loss

검색결과 852건 처리시간 0.024초

Stray Load Loss Analysis of Canned Induction Motor for Hermetic Compressor

  • Yamazaki Katsumi;Haruishi Yoshihisa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.224-228
    • /
    • 2005
  • In this paper, we investigate the main components of stray load loss of induction motors for ammonia compressors. The variations of the losses at each part of the motor due to load are calculated by the combined 3-D-2D finite element method formulated by the mixed moving coordinate systems. The stray load loss is calculated from these results due the definition of IEEE standard-112. It is clarified that the core loss and the eddy current loss of the can increase due to load, which can be considered as the main part of the stray load loss.

AHP 분석을 이용한 금융기관 운영리스크 측정 (Operational Risk Measurement of Financial Institutions via AHP)

  • 최승일
    • 경영과학
    • /
    • 제28권3호
    • /
    • pp.73-82
    • /
    • 2011
  • Basel II advanced measurement approaches for operational risk need to estimate the frequency and severity distribution of operational losses. Due to lack of internal loss data, the estimation is impossible in many cases and so external loss data might be used by scaling on asset or gross income. To get around lack of loss data, scenario analysis combined with loss distribution approach can be useful in calculating the capital charge of operational risk. However, scenario based loss distribution approach requires much time and effort. Instead we may apply the analytic hierarchy process to measure operational risk of financial institutions. The analytic hierarchy process combined with loss distribution approach is to estimate the capital charge of operational risk in other areas based on the operational VaR in an area with sufficient loss data. AHP provides a tool for timely measurement of operational risk in this rapidly changing global environment.

A Modification of the Combined Estimator of Inter- and Intra-Block Estimators under an Arbitrary Convex Loss Function

  • Lee, Young-Jo
    • Journal of the Korean Statistical Society
    • /
    • 제16권1호
    • /
    • pp.21-25
    • /
    • 1987
  • The combined estimator of inter- and intra-block estimators in incomplete block designs can be expressed as a weighted average of two location estimators. The weight should be between 0 and 1. However, the negative variance component estimate could result in the weight being negative or larger than 1. In this paper, we show that if two location estimators have symmetric unimodal distributions, truncating the weight to 0 or 1 accordingly improves the combined estimator under an arbitrary convex loss function.

  • PDF

한방 복합 치료 및 소리재활치료로 호전된 양측성 돌발성 난청 치험 1례 (Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Bilateral Sudden Sensorineural Hearing Loss : A Case Report)

  • 박소영;제하경;민예은;강준혁;홍은빈
    • 한방안이비인후피부과학회지
    • /
    • 제35권2호
    • /
    • pp.72-81
    • /
    • 2022
  • Objectives : The purpose of this study is to report the case of a bilateral sudden sensorineural hearing loss patient whose hearing had improved by Korean medical treatment combined with threshold sound. Methods : A woman diagnosed with bilateral sudden sensorineural hearing loss has treated with Korean medical interventions(acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and threshold sound conditioning(TSC) for 20 weeks. Pure tone audiometry(PTA) was performed for the evaluation. Results : The average hearing level has improved from mild to normal level. The level of tinnitus has decreased from VAS 10 to VAS 4. Conclusions : We observed an improvement in a bilateral sudden sensorineural hearing loss patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss.

A Study on the Multiresponse Robust Design using Loss Function

  • Kwon, Yong-Man;Chang, Duk-Joon
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2005년도 춘계학술대회
    • /
    • pp.1-6
    • /
    • 2005
  • In this paper we propose how to simultaneously optimize multiple responses for robust design when data are collected from a combined array. The proposed method is based on the quadratic loss function. An example is illustrated to show the proposed method.

  • PDF

Loss Function Approach to Multiresponse Robust Design

  • Chang, Duk-Joon;Kwon, Yong-Man
    • Journal of the Korean Data and Information Science Society
    • /
    • 제16권2호
    • /
    • pp.255-261
    • /
    • 2005
  • Many designed experiments require the simultaneous optimization of multiple responses. In this paper, we propose how to simultaneously optimize multiple responses for robust design when data are collected from a combined array. The proposed method is based on the quadratic loss function. An example is illustrated to show the proposed method.

  • PDF

Simultaneous Optimization Using Loss Functions in Multiple Response Robust Designs

  • Kwon, Yong Man
    • 통합자연과학논문집
    • /
    • 제14권3호
    • /
    • pp.73-77
    • /
    • 2021
  • Robust design is an approach to reduce the performance variation of mutiple responses in products and processes. In fact, in many experimental designs require the simultaneous optimization of multiple responses. In this paper, we propose how to simultaneously optimize multiple responses for robust design when data are collected from a combined array. The proposed method is based on the quadratic loss function. An example is illustrated to show the proposed method.

스털링 기관용 재생기에 관한 기초 연구 (III) - 복합메쉬 철망을 축열재로 한 재생기의 전열 및 유동손실 특성 - (Basic Study on the Regenerator of Stilting Engine (III) - Heat Transfer and Flow Friction Characteristic of the Regenerator with Combined Wire-mesh Matrix -)

  • 이시민;김태한
    • Journal of Biosystems Engineering
    • /
    • 제30권4호
    • /
    • pp.195-201
    • /
    • 2005
  • The output of Stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide a basic data for the design of regenerator matrix, characteristics of heat transfer and flow friction loss were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, several kinds of combined wire screen meshes were used. The results are summarized as follows; The packed meshes with high mesh no. in the side of heater part of regenerator showed effective than the packed meshes with low mesh no. in the side of cooler part of regenerator. The temperature difference and pressure drop of the regenerator were not made by the specific surface area of wire screen meshes but by the minimum free-flow area to the total frontal area. Among the No. 150 single screen meshes, 200-60 combined meshes, the 200-150-100 combined meshes showed the highest in effectiveness.

Combined Features with Global and Local Features for Gas Classification

  • Choi, Sang-Il
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권9호
    • /
    • pp.11-18
    • /
    • 2016
  • In this paper, we propose a gas classification method using combined features for an electronic nose system that performs well even when some loss occurs in measuring data samples. We first divide the entire measurement for a data sample into three local sections, which are the stabilization, exposure, and purge; local features are then extracted from each section. Based on the discrimination analysis, measurements of the discriminative information amounts are taken. Subsequently, the local features that have a large amount of discriminative information are chosen to compose the combined features together with the global features that extracted from the entire measurement section of the data sample. The experimental results show that the combined features by the proposed method gives better classification performance for a variety of volatile organic compound data than the other feature types, especially when there is data loss.

액체수소 저장용기의 열해석 (Thermal Analysis of a Liquid Hydrogen Vessel)

  • 김서영;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.57-65
    • /
    • 1997
  • Thermal analysis has been performed to design a high-performance $LH_2$ vessel with about 1% per day evaporation loss. Analysis includes the combined insulations of MLI(Multi-Layer Insulation) and VCS (Vapor-Cooled Shield) under high vacuum. Combined insulation of MLI and VCS shows the existence of optimal location of VCS to minimize evaporation loss. Comparison of parallel-type DVCS (Double Vapor-Cooled Shield) and serial-type DVCS is also made to show the effectiveness of the system. The results indicate that the serial-type DVCS vessel is better than the parallel-type DVCS vessel with respect to overall evaporation loss. The combined insulation of SVCS (Single Vapor-Cooled Shield) with a partial MLI can give a similar performance characteristics compared to that with MLI and DVCS.

  • PDF