• Title/Summary/Keyword: Combined Deterioration

Search Result 180, Processing Time 0.034 seconds

Characterization and Enhancement of Package O2 Barrier against Oxidative Deterioration of Powdered Infant Formula

  • Jo, Min Gyeong;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.1
    • /
    • pp.13-16
    • /
    • 2018
  • Powdered infant formula is susceptible to oxidation in the presence of oxygen. Even though the product is usually packaged in nitrogen atmosphere, the oxygen ingress through the package layer may occur in case of flexible pouches and affects the oxidation of the product. $O_2$ barrier of the package is thus important variable to protect the product from oxidative deterioration. $O_2$ barrier property was investigated for aluminum-laminated small pillow packs of $3.5{\times}17.5cm$. Storage temperature and combination of primary and secondary packages were evaluated as variables affecting the barrier for conditions of empty pouch flushed with nitrogen. Apparent oxygen transmission rate of the primary package exposed to air was $2.32{\times}10^{-3}mL\;(STP)\;atm^{-1}\;d^{-1}$ at $30^{\circ}C$ and its temperature dependence could be explained by activation energy of $28.5kJ\;mol^{-1}$ in Arrhenius relationship. The additional secondary package of nylon/PE film containing 20 primary packages was ineffective in modulating package $O_2$ transmission and was only marginally helpful when combined with oxygen scavenger. The same was true in suppressing the product oxidation when the primary package was filled with 14 g of the formula.

Direct Numerical Simulation of Turbulent Heat Transfer to Fluids at Supercritical Pressure Flowing in Vertical Tubes (직접수치모사를 이용한 수직원형관내 초임계압 유체의 난류 열전달 특성 연구)

  • Bae, Joong-Hun;Yoo, Jung-Yul;Choi, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1302-1314
    • /
    • 2004
  • Turbulent heat transfer to $CO_2$ at supercritical pressure flowing in vertical tubes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play a major role in turbulent heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface. Based on the results of the present DNS combined with theoretical considerations, the physical mechanism of this local heat transfer deterioration is elucidated.

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.1
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.

Service life prediction of a reinforced concrete bridge exposed to chloride induced deterioration

  • Papadakis, Vagelis G.
    • Advances in concrete construction
    • /
    • v.1 no.3
    • /
    • pp.201-213
    • /
    • 2013
  • While recognizing the problem of reinforcement corrosion and premature structural deterioration of reinforced concrete (RC) structures as a combined effect of mechanical and environmental actions (carbonation, ingress of chlorides), emphasis is given on the effect of the latter, as most severe and unpredictable action. In this study, a simulation tool, based on proven predictive models utilizing principles of chemical and material engineering, for the estimation of concrete service life is applied on an existing reinforced concrete bridge (${\O}$resund Link) located in a chloride environment. After a brief introduction to the structure of the models used, emphasis is given on the physicochemical processes in concrete leading to chloride induced corrosion of the embedded reinforcement. By taking under consideration the concrete, structural and environmental properties of the bridge investigated, an accurate prediction of its service life is taking place. It was observed that the proposed, and already used, relationship of service lifetime- cover is almost identical with a mean line between the lines derived from the minimum and maximum critical values considered for corrosion initiation. Thus, an excellent agreement with the project specifications is observed despite the different ways used to approach the problem. Furthermore, different scenarios of concrete cover failure, in the case when a coating is utilized, and extreme deicing salts attack are also investigated.

Monitoring Technology on the Surface Condition after Conservation Treatment of Stone Cultural Heritage (석조문화재의 보존처리 후 표면상태 모니터링 기술 연구)

  • Park, Sung Mi;Chun, Yu Gun;Lee, Myeong Seong
    • 보존과학연구
    • /
    • s.34
    • /
    • pp.32-48
    • /
    • 2013
  • This study examined the applicability of deterioration monitoring techniques to establish efficient conservation and management system for stone cultural heritage which conservation treatment has been done. It was confirmed that deterioration mapping combined with photography and grid work, and adhesive tape test for the surface were very applicable to investigate the surface change due to deterioration, and assess the degree of granular disintegration quantitatively. The portable microscopic survey and ultrasonic measurement were efficient techniques to observe mineral looseness and microcrack, and to track the strength change of the stone before-and-after the conservation treatment. These techniques can be easily used by manage practitioners in the field through simple guidance and technical education. Also, it can contribute to build a long-term and methodical conservation and management system of the stone cultural heritage.

  • PDF

Consideration of Making Techniques and Deterioration Assessment using Radiography for the Iron Buddha Statues (방사선 투과촬영을 활용한 철불의 손상도 평가 및 제작기법 고찰)

  • Han, Na Ra;Lee, Chan Hee;Yi, Jeong Eun
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.81-93
    • /
    • 2014
  • As the Seated Iron Buddha Statues, Vairocana Buddha of Dopiansa Temple in Cheolwon, Nosana Buddha of Samhwasa Temple in Donghae and Sakyamuni of Mangisa Temple in Pyeongtaek were made during Unified Silla to Koryo Dynasty. These are damaged degradation which are crack, break-out, peel off and various pollutant. As a result of deterioration evaluation using radiography, crack, gap, break-out, pore space and restoration material are confirmed inside in the Buddha Statues. Based on iron strength, the Buddha Statues will be maintain current state as long as a high external impact is not applied. Also, iron core and nails used for fixing of internal and external framework were observed in the Buddha Statues. According to prominent line of surface, embossed inscription, hands cast separately and combined, the Buddha Statues were made by using division casting.

Properties on the Freeze-Thaw of Concrete Subjected to Seawater Attack (해수의 영향을 받은 콘크리트의 동결융해 특성)

  • Park, Kwang-Pil;Kim, Seong-Soo;Lee, Seung-Tae;Kim, Jong-Pil;Jung, Ho-Seop
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • In this study, deterioration degrees of concrete were investigated at laboratory under seawater attack and cycling freeze-thaw, which are major durability performance deterioration factors of concrete. Deteriorations of mixed concrete using Portland & blended cement were examined by instrumental analysis of changes in relative dynamic modulus of elasticity and compressive strength. After 520 cycles of freeze-thaw, relative dynamic modulus of elasticity and compressive strength of concrete mixed with normal Portland and LHC over 75% showed relatively low resistance of approximately 44% of those values of SRC. Concrete replaced with 50% fine powder of blast furnace slag showed the most excellent freeze-thaw resistance among the tested blended cement concrete.

An Experimental Study on the Pore Structure Property of Concrete by Carbonation (탄산화 작용에 따른 콘크리트의 세공구조 성상에 관한 실험적 연구)

  • Kim, Young-Bong;Kim, Young-Sun;Lee, Eui-Bae;Na, Chul-Sung;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.537-540
    • /
    • 2008
  • Up to now, the RC structures have been recognized as being socially semi-permanent. But in recent years there were reports about the cases of early deterioration of RC structures. Most of all pore structure effects on the durability of concrete as well as mechanical properties of concrete. Therefore, in this study, mixing design was proportioned with the water-binder ratio 0.55 binder compositions corresponding to cement without any supplementary materials(OPC), cement with 50% blast-furnace slag replacement (BFS50), cement with 15% fly ash replacement (FA15), and ternary cement with cement, 15% fly ash, and 35% slag replacement (BFS35+FA15). And this study is to compare pore structure property of concrete by carbonation to investigate the effect of the permeation of deterioration factors such as $CO_2$ and chloride ion under the combined deterioration environments. The results showed that pore volume effects on the diffusibility of chloride ion.

  • PDF

A Case Report on Posterior Circulation Cerebral Infarction with Early Neurological Deterioration in an Elderly Patient with Chronic Kidney Disease (고령의 만성콩팥병 환자에서 발생한 초기 신경학적 악화가 동반된 후방순환뇌경색 치험 1례)

  • Kim, Jun-seok;Lee, Yoo-na;An, Yu-min;Baek, Kyung-min
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.727-737
    • /
    • 2021
  • Objectives: This study investigated the effect of Korean medicine on an elderly patient with posterior circulation cerebral infarction, chronic kidney disease (CKD), and early neurological deterioration (END). Methods: The patient, who already had CKD, was treated with Korean medicine, comprising herbal medicine, acupuncture, moxa, and cupping combined with Western medicine (antiplatelet, diabetes) and physical therapy. A manual muscle test (MMT) and a modified Barthel index (MBI) were used to observe the treatment effects, and blood tests were performed to check estimated glomerular filtration rate (eGFR), creatinine and blood urea nitrogen (BUN), which represent renal function. Results: After the treatment, MMT, MBI, and renal function scores had increased. Conclusions: This study suggests that Korean medicine can effectively treat posterior circulation cerebral infarction with END in CKD, but further studies should be conducted.

Petrological Characteristics and Nondestructive Deterioration Assessments for Foundation Stones of the Sebyeonggwan Hall in Tongyeong, Korea (통영 세병관 초석의 암석학적 특성 및 비파괴 손상평가)

  • Han, Doo Roo;Kim, Sung Han;Park, Seok Tae;Lee, Chan Hee
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.199-212
    • /
    • 2021
  • The Sebyeonggwan Hall (National Treasure No. 305) is located on the Naval Headquarter of Three Provinces in Tongyeong, and it has partly undergone with several rebuilding, remodeling, repairing and restorations since it's the first establishment in Joseon Dynasty (AD 1605) of ancient Korea. This study focuses on 50 foundation stones that comprise the Sebyeonggwan. These stones are made of six rock types and currently have various shapes of the surface damages. As the foundation stones, the dominant rock type was dacitic lapilli tuffs, and provenance-based interpretation was performed to supply alternative stones for conservation. Most of the provenance rocks for foundation stones showed highly homogeneity with their corresponding stones of petrography, mineralogy and magnetic susceptibility. According to surface deterioration assessments, the most serious damages of the stones were blistering and scaling. The deterioration mechanism was identified through the analysis of inorganic contaminants, and the primary reason is considered salt weathering caused by sea breeze and other combined circumstances. Based on the mechanical durability of the stones, there was no foundation stone that required the replacement of its members attributed to the degradation of the rock properties, but conservation treatment is considered necessary to delay superficial damage. The foundation stones are characterized by a combined outcome of multiple petrological factors that caused physical damage to surfaces and internal defects. Therefore, it's required to diagnosis and monitoring the Sebyeonggwan regularly for long-term preservation.