• 제목/요약/키워드: Combination resonance

검색결과 222건 처리시간 0.038초

경추 추간판 탈출증 입원 환자 102례에 관한 한의학적 복합치료 효과의 관찰 연구 (Effects of Korean Medical Combination Treatment for 102 Cases of Cervical Disc Herniation : An Observational Study)

  • 최지훈;이순호;김상민;김현중;구자성;이현호;정성현;윤덕원
    • Journal of Acupuncture Research
    • /
    • 제33권2호
    • /
    • pp.11-20
    • /
    • 2016
  • Objectives : The purpose of this study is to investigate the clinical effectiveness of Korean medical combination treatment for cervical disc herniation. Methods : This is an observational study. 102 patients diagnosed with cervical disc herniation by MRI (Magnetic Resonance Imaging) were investigated from January, 2015 through to December, 2015 at Daejeon Jaseng Hospital of Korean Medicine. They were sorted according to the distribution of sex, age, causing factor, the period of disease, admission day and pain area. All patients were treated with acupuncture, Chuna treatment, and herbal therapy and physical therapy during the admission period. After treatment, NRS (Numeric Rating Scale), NDI (Neck Disability Index) and EQ-5D were assessed to evaluate the treatment efficacy. Results : There were more females than Males with a ratio of 1 : 1.37, the age of fifty was the most with 35.29 %, reason unknown was the most with 72.55 % and the subacute stage was the most with 38.24 %. According to disc herniation types, patients with protruded disc types were the most with 66.67 % and a lesion of C5/6 was the most with 41.18 %. For patients diagnosed with cervical disc herniation, neck and shoulder pain NRS decreased from $6.43{\pm}1.77$ to $3.96{\pm}1.96$(p<0.001) and radiating pain NRS decreased from $5.64{\pm}1.96$ to $3.57{\pm}1.88$ (p<0.001). NDI decreased from $41.72{\pm}14.04$ to $30.84{\pm}15.34$(p<0.001), and the EQ-5D index increased from $0.68{\pm}0.17$ to $0.79{\pm}0.14$(p<0.001) after treating cervical disc patients. Conclusion : Korean medical combination treatment might be effective in decreasing pain and raising the life quality of patients with cervical disc herniation.

소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구 (Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer)

  • 이훈희;정창원
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.16-21
    • /
    • 2017
  • 본 논문은 모바일 기기(노트북, 핸드폰, 태블릿 PC 등)를 위한 공진형 무선전력전송 시스템(Magnetic Resonance - Wireless Power Transfer; MR-WPT)의 실용성을 높이기 위한 평면형 소형 공진기 설계 방법을 제안하였다. 제안된 소형 평면형 공진기는 네 개의 루프와 공진기를 사용하는 공진형 무선전력 시스템에 적용 되며, 또한 무선전력 시스템은 송신기(Tx)와 수신기(Rx)가 동일한 루프와 공진기로 이루어졌다. 제안된 공진기는 나선형(Spiral) 코일의 형태로 소형 모바일 크기에 적합한 $50mm{\times}50mm$의 크기 이내로 설계 되었으며, 나선형 공진기의 선 두께와 선간 갭(gap) 그리고 선의 길이를 달리하는 4종류의 나선형 공진기를 선정하였다. 또한 작은 공진기 부피에서 높은 인덕턴스와 캐패시턴스를 얻기 위해 공진기 기판 (아크릴 ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$)의 양면을 모두 활용하였다. 또한 루프는 공진기 부피를 최소화하기 위해 공진기와 동일 평면상에 설계 하였고, 이 또한 서로 다른 3가지의 크기를 사용하였다. 제안된 무선전력전송 시스템은 Tx와 Rx 두 개의 아크릴 기판에 제작되었으며, Tx와 Rx의 루프와 공진기는 구리시트로 만들어졌다. 제안된 12개의 조합 (공진기 4종 ${\times}$ 루프 3종)의 루프와 공진기에 대한 전력전송효율을 근 전송 거리 (1cm~5cm)상에서 시뮬레이션과 측정을 통해 산출하였다. 측정 결과 전력전송효율은 전송거리 1~5 cm에 따라 ${\fallingdotseq}40%$ 그리고 최대 ${\fallingdotseq}70%$ 이며, 이때 공진주파수는 A4WP 표준 무선전력전송 주파수인${\fallingdotseq}6.78MHz$를 유지한다. 제안된 부피에서 최소화된 평면형의 소형 공진기를 이용한 소형 모바일 기기의 공진형 무선전력 어플리케이션에 대한 가능성을 실험적으로 확인하였다.

LTCC 공법을 사용한 Cellular/SDMB 안테나-다이플렉서 모듈 (Antenna-Diplexer Module for Cellular/SDMB Band Using LTCC Technology)

  • 하정욱;장기훈;윤영중
    • 한국전자파학회논문지
    • /
    • 제18권7호
    • /
    • pp.774-783
    • /
    • 2007
  • 본 논문은 Cellular 대역과 SDMB(Satellite Digital Multimedia Broadcasting) 대역에서 동작하는 무선 통신 시스템을 위한 송수신 전치단의 소형 안테나-다이플렉서 모듈을 설계하고 구현하는 방법을 제안한다. 제안된 모듈은 이중 공진 안테나와 다이플렉서로 구성되고, 저 손실과 소형화를 동시에 달성하기 위해 다층의 LTCC(Low Temperature Co-fired Ceramic) 기술을 이용하여 제작되었다. 이중 공진 안테나는 소형화를 위해 미앤더 라인을 사용하였고, 임피던스 매칭을 쉽게 이루기 위해 IFA(Inverted-F Antenna) 구조를 응용하여 설계하였으며, 간단한 구조를 지니면서 사양을 만족하는 이득과 대역폭을 갖는다. 다이플렉서는 저역 통과 필터 및 고역 통과 필터를 결합하여 설계되었고, 이들 사이의 상호 간섭을 줄임으로써 높은 격리도를 얻을 수 있었다. 제작된 모듈의 크기는 $27.5{\times}12.0{\times}2.2mm$이고, $813{\sim}902MHz,\;2,586{\sim}2,655MHz$의 동작 주파수 대역과 -1.96 dBi(cellular band), -5.43 dBi(SDMB band)의 이득이 측정되었다. 주파수 응답 특성과 방사 특성이 분석되었다.

Interobserver variation in target volume for salvage radiotherapy in recurrent prostate cancer patients after radical prostatectomy using CT versus combined CT and MRI: a multicenter study (KROG 13-11)

  • Lee, Eonju;Park, Won;Ahn, Sung Hwan;Cho, Jae Ho;Kim, Jin Hee;Cho, Kwan Ho;Choi, Young Min;Kim, Jae-Sung;Kim, Jin Ho;Jang, Hong-Seok;Kim, Young-Seok;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.11-16
    • /
    • 2018
  • Purpose: To investigate interobserver variation in target volume delineations for prostate cancer salvage radiotherapy using planning computed tomography (CT) versus combined planning CT and magnetic resonance imaging (MRI). Materials and Methods: Ten radiation oncologists independently delineated a target volume on the planning CT scans of five cases with different pathological status after radical prostatectomy. Two weeks later, this was repeated with the addition of planning MRI. The volumes obtained with CT only and combined CT and MRI were compared, and the effect of the addition of planning MRI on interobserver variability was assessed. Results: There were large differences in clinical target volume (CTV) delineated by each observer, regardless of the addition of planning MRI ($9.44-139.27cm^3$ in CT only and $7.77-122.83cm^3$ in CT plus MRI) and no significant differences in the mean and standard deviation of CTV. However, there were decreases in mean volume and standard deviation as a result of using the planning MRI. Conclusion: This study showed substantial interobserver variation in target volume delineation for salvage radiotherapy. The combination of planning MRI with CT tended to decrease the target volume and the variation.

치와와견에서 발생한 비강 신경내분비암종의 침윤에 의한 이차적인 뇌종양 증례; 자기공명영상과 조직학적 특성 (Secondary Brain Tumor Caused by Infiltration of Nasal Neuroendocrine Carcinoma in a Chihuahua Dog: Clinical, Magnetic Resonance Imaging and Histopathological Findings)

  • 정동인;강병택;김주원;김하정;박희명
    • 한국임상수의학회지
    • /
    • 제27권2호
    • /
    • pp.186-189
    • /
    • 2010
  • 14년 령의 암컷 치와와견이 발작증세 및 좌측으로의 선회운동 증상을 보여 내원하였다. 신경검사결과 좌측 대뇌 병변이 의심되어 자기공명영상 촬영을 실시하여 좌측 비강에서 좌측 대뇌로 파급된 병변을 확인하였다. 영상 분석 상에서 비강 내에서 유래된 2차적인 뇌종양이 강력하게 의심되었다. 환자의 증상은 프레드니솔론과 로무스틴의 혼합치료 후 상당히 개선되었고 진단 후 2개월간 생존하였다. 조직 검사 결과 비강에서 유래한 신경내분비암종으로 확진되었다. 본 증례보고는 개에서 발생한 비강유래 신경내분비암종의 침윤에 의한 2차적인 뇌종양의 임상적인 특징, 영상 진단 결과, 그리고 조직학적인 특성을 잘 보여주고 있다.

수직 진동하는 소수성 표면 위 액적의 내부유동 및 증발특성 연구 (Internal Flow and Evaporation Characteristic inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface)

  • 김훈;임희창
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.579-589
    • /
    • 2015
  • 본 연구의 목적은 수직으로 강제 진동하는 소수성 표면 위에 놓인 액적의 유동 및 증발 특성을 이해하는 것이다. 액적의 공진주파수를 예측하기 위해서 Lamb과 Strani and Sabetta의 이론적 고유진동수식을 이용하였고, 실험값과 비교하여 보다 근접한 고유진동수 식에 대해 타당성을 검증하였다. 액적의 형상 및 내부 유동을 가시화하기 위해 초고속카메라, 초접사렌즈 그리고 연속광을 사용하여 진동하는 소수성 표면 위 액적의 유동 및 증발 특성을 확인하였다. 그 결과 각각의 모드에서 액적은 다양한 형상을 가졌으며, 각각의 액적 내부에서 복잡한 와류가 관찰되었다. 일반적으로, 유동흐름이 대칭축을 따라 위로 상승하여 액적상단에서 표면을 따라 접촉선부근으로 이동하였고, 2차, 4차 모드는 분기형, 6차, 8차 모드는 큰 타원형의 유동패턴을 갖는 것을 확인하였다. 여러 가지 모드 중 4차 모드에서 가장 빠른 유동속도를 가졌으며, 다음은 8, 6, 2차 모드 순서였다. 네 가지 진동 모드에서의 증발률은 4, 8, 6, 2차 모드 순서로 빨랐으며, 각각의 공진에서는 그 주위 주파수 영역보다 빠른 증발률을 보였다. 마지막으로 진동을 이용한 액적의 증발은 4차 모드에서 진행되어야 보다 효율적인 진동 증발을 유도할 수 있다.

연조직종양의 조직 성분 평가를 위한 자기공명영상: MEDIC 과 지방억제 T2 영상의 비교 (MRI Evaluation for the Histologic Components of Soft-tissue Tumors: Comparison of MEDIC and Fast SE T2-weighted Imaging)

  • 문태용;이인숙;이준우;최경운;김정일;김의신
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2008
  • 목적: 연조직종양의 조직 성분을 자기공명영상으로 평가하는데 MEDIC과 지방억제 T2 영상을 비교하여 더 나은 검사방법을 선택하고자 하였다. 대상 및 방법: 병리조직학적으로 진단된 연조직종양 10예 (신경집종 3예, 혈관종 2예, 지방종 1예, 혈관각화종 1예, 윤활막육종 1예, 지방육종 1예 그리고 악성섬유조직구종 1예)에서 25 조직 성분 (혈관 5예, 신경 4예, 섬유성 4예, 과세포성 4예, 출혈성괴사 2예, 낭성 2예, 지방성 2예, 점액버팀질 1예, 그리고 혈전 1예)을 선택하였다. 병리조직학적 조직 성분과 일치하는 동일 단면상을 가진 MEDIC과 지방억제 T2영상에 동일한 크기의 관심영역을 그려 불균질치를 얻었다. 불균질치는 영상의 불균질성을 나타내는 표준편차 값을 관심영역에서 얻은 신호강도 평균값으로 나눈 값으로 하였다. 결과: 25 조직 성분의 불균질치는 MEDIC 보다 지방억제 T2영상에서 높게 나타났다 (p < .001). 결론: MEDIC 영상은 불균질치가 현저히 낮으므로, 자기공명영상으로 연조직종양의 조직 성분을 평가하는데 지방억제 T2영상 보다 MEDIC 영상이 더 유용할 것으로 사료된다.

  • PDF

HPLC와 NMR를 이용한 염미성 펩타이드 분석방법 검증 (An Analytical Method for the Validation of a Salt-enhancing Peptide Using a Liquid Chromatography and a Nuclear Magnetic Resonance (NMR) Spectroscopy)

  • 박선유;정용진;김미연;황지홍;권택규;서영호
    • 생명과학회지
    • /
    • 제27권11호
    • /
    • pp.1324-1330
    • /
    • 2017
  • 최근 염분의 섭취와 관련하여 건강에 대한 우려가 늘어남에 따라, 염미대체제에 대한 소비자들의 관심이 급증하고 있으며, 세계적으로 경쟁력 있는 천연 저염제품의 개발이 필요한 실정이다. 최근 연구를 통해 식물성 및 동물성 원료 배합을 통해 가수분해물을 조제하여 최적 화합물을 얻는 것에 성공하였다. 본 연구에서는 염미성 펩타이드 분말내 arginine을 함유한 염미성 펩타이드를 규명하고 정량 하고자 하였다. L-arginine 또는 arginine을 포함한 펩타이드를 표준물질로 하여 $^{13}C$-NMR로 분석한 결과 유사한 위치에 구아니딘기 탄소가 시그널(L-arginine: 156.8 ppm, Arg-Ala: 156.4 ppm, Arg-Ser: 156.4 ppm)이 나타남을 확인하였고, 이를 통해 간편하고 신속하게 arginine 함유 펩타이드 정량분석이 가능할 것으로 기대된다.

직구동 전기기계식 구동기의 강성요구규격에 기반한 설계용 해석모델 (Analysis Model for Design Based on Stiffness Requirement of Direct Drive Electromechanical Actuator)

  • 오상관;이희중;박현종;오동호
    • 한국항공우주학회지
    • /
    • 제47권10호
    • /
    • pp.738-746
    • /
    • 2019
  • 한국형발사체 3단에 사용되는 7톤 짐벌엔진의 추력벡터제어에는 전기유압식 구동장치시스템 대신 중량, 비용 및 시험평가 등의 측면에서 더 효율적인 전기기계식 구동장치시스템을 사용한다. 전기기계식 구동기는 위치제어 서보 구동기로 고진공에서도 운용 가능한 BLDC 모터를 사용한다. 짐벌엔진을 갖는 발사체의 경우 구동기 자체 진동모드와 구동기를 지지하는 기체구조체의 벤딩모드, 짐벌엔진의 관성부하 등이 조합되어 합성공진 현상이 발생할 수 있다. 합성공진이 발생할 경우 발사체 자세제어는 불안정해진다. 이러한 관계로 짐벌엔진 및 기체구조체 지지부, 구동장치시스템의 고유 특성을 고려하여 강성에 대한 요구규격이 적용되어 왔다. 한국형발사체 3단 7톤 짐벌엔진의 경우 구동장치시스템의 강성요구규격은 $3.94{\times}10^7N/m$ 수준이며 이를 만족시키기 위한 직구동 방식전기기계식 구동기를 설계하였다. 본 논문에서는 강성요구규격을 기반으로 설계된 직구동 전기기계식 구동기의 등가강성 해석모델을 제안하고, 이를 실험결과로 검증하였다.

준 슬라이딩 모드 제어를 이용한 선박의 종동요 및 횡동요 억제 (Suppression of Coupled Pitch-Roll Motions using Quasi-Sliding Mode Control)

  • 이상도;트롱 엥곡 쿠옹;서효;유삼상
    • 해양환경안전학회지
    • /
    • 제27권2호
    • /
    • pp.211-218
    • /
    • 2021
  • 본 연구는 종방향과 횡방향에서 규칙파가 외란으로 입사하는 선박의 종동요 및 횡동요를 억제하는 문제를 다룬다. 선박의 안전 운항을 위해서 파랑 중 선박의 종동요 및 횡동요를 안정화시키는 것은 필수적인 과제로 여겨진다. 종동요 및 횡동요 거동에서 중요한 특징 중에 하나는 공진인데, 이 현상은 특정한 조건에서 예상치 못한 큰 응답을 초래한다. 종동요와 횡동요는 두 운동이 상호 결합되어 있고 복원항이 강한 비선형을 갖고 있음으로 계의 파라미터에 따라 다양한 동적 거동을 보이는 것이 중요한 특징인데, 특히 종동요에서 이 특성이 두드러지게 나타난다. 무엇보다, 선박의 조종성능 및 안전을 위해 선박의 종동요 가속도 응답을 완전히 억제하는 것은 상당히 도전적인 과제이다. 이 연구에서는 준 슬라이딩 모드 제어 기법을 이용하여 종동요와 횡동요를 줄임으로 파랑 중의 선박을 안정적인 직립 상태로 유지시키고, 아울러 채터링을 감소시키는 목적을 달성하였다. 리아프노프 이론으로 준 슬라이딩 모드 제어의 안정성을 판명하였고, 수치 시뮬레이션으로 제어 방식의 유효성을 증명하였다. 제시한 기법으로 종동요 및 횡동요 응답의 수렴 및 채터링 감소라는 두 가지 목표가 효과적으로 달성되었다.