• Title/Summary/Keyword: Column scanning

Search Result 86, Processing Time 0.033 seconds

Preliminary Investigation for Feasibility of Wave Energy Converters and the Surrounding Sea as Test-site for Marine Equipment

  • Park, Jin-Yeong;Baek, Hyuk;Shim, Hyungwon;Choi, Jong-Su
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.351-360
    • /
    • 2020
  • Of late, demand for test sites for marine equipment such as ASV, AUV, ROV, and various underwater sensors is increasing. The authors have focused on an oscillating water column (OWC), which is being constructed near Chagwido Island Jeju, as one of the test-sites. The main objective of the OWC is to produce wave energy and develop technologies. It has been built in the sea approximately 1 km off the coast. It has berth accommodation and some rooms that can be used as laboratories. To investigate the feasibility of its usage as a test site for marine equipment, we acquired bathymetric data around the OWC by using a multi-beam echo sounder and a single-beam scanning sonar. The accessibility of the OWC from nearby ports and the use of support vessels or ships were also investigated. 3D point cloud data from the multi-beam echo sounder and 2D acoustic images from the scanning sonar are expected to be used as references for identifying changes over time. In addition, through these experiments, we derived a procedure to use this facility as a test site by using the IDEF0 functional modelling method. Based on this preliminary investigation and previously reported examples, we determined the general conditions and preferences for evaluating the performance of various marine equipment heuristically. Finally, we developed five applications that were derived from this investigation.

Development of a multi-functional nano-fabrication system for fabrication and measurement (가공 및 측정이 가능한 복합나노가공시스템의 개발)

  • 장동영;박만진;김진현;한동철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.466-471
    • /
    • 2004
  • In focused-ion-beam (FIB) application of micromachining and device transplantation, four kinds of FIB processes, namely FIB sputtering, FIB-induced etching, redeposition, and FIB-induced deposition, are well utilized. As with FIB systems, scanning electron microscopes(SEMs) were extensively used in the semiconductor industry. They are the tools of choice for defect review and providing the image resolution needed for process monitoring. The enhanced capabilities of a dual-column on one chamber system are quickly becoming realized by the nano industry for performing a wide range of application.

  • PDF

Action on the 7S Globulin of Bacilus sp. IJ-3 Enzyme

  • Park, Yang-Won
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.2
    • /
    • pp.128-132
    • /
    • 1998
  • 7S globulin has been isolate from the defatted soybean meal(glycine max,. merill) by Sepharose-6B column chromatography and CM-Sephadex column chromatography. Coagulum of 7S globulin formed at a temperature of $65^{\circ}C$ in microbial enzyme treatment. In order to characterize the structure of the coagulum, three kinds of coagulum (enzyme-, calcium-and acid-induced coagulum)were compared througth the Scanning Electron Microscope(SEM). The network structure was found to be of two levels. First, there was an appearance on the molecular level in the form of strands. Second, there was a denser network with a fine structure.

  • PDF

Scanning Electron Microscopic Study of the Sertoli Cell in the Korean Native Bull (한우 Sertoli 세포의 주사전자현미경적 연구)

  • 이성호;박영석
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.448-453
    • /
    • 1999
  • The three-dimensional structure of the Sertoli cell in the Korean native bull was investigated by scanning electron microscopy. Morphologically, four types of Sertoli cell processes were evident: 1) sheet-like processes, 2) sleeve-like processes, 3) bough-like processes and 4) finger-like processes. The sheet-like processes rested upon more than half of the surface of each spermatogonia, spermatocyte and spermatid. Sleeve-like processes, bough-like processes and finger-like processes are observed in the middle and apical portion of seminiferous tubule. All Sertoli cell processes are originated from Sertoli cell column. Just before spermiation, the apical sheet-like processes are shifted from their position at the spermatid head, and bough-like processes covered the disengaged residual body, after which the residual body was no longer evident in the tubule. Though the mechanism for this elimination is not known, the process suggests a reciprocity between the Sertoli and germ cells.

  • PDF

3D Map Building of The Mobile Robot Using Structured Light

  • Lee, Oon-Kyu;Kim, Min-Young;Cho, Hyung-Suck;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.123.1-123
    • /
    • 2001
  • For Autonomous navigation of the mobile robots, the robots' capability to recognize 3D environment is necessary. In this paper, an on-line 3D map building method for autonomous mobile robots is proposed. To get range data on the environment, we use an sensor system which is composed of a structured light and a CCD camera based on optimal triangulation. The structured laser is projected as a horizontal strip on the scene. The sensor system can rotate $\pm$ $30{\Circ}$ with a goniometer. Scanning the system, we get the laser strip image for the environments and update planes composing the environment by some image processing steps. From the laser strip on the captured image, we find a center point of each column, and make line segments through blobbing these center poings. Then, the planes of the environments are updated. These steps are done on-line in scanning phase. With the proposed method, we can efficiently get a 3D map about the structured environment.

  • PDF

3D Map Building of the Mobile Robot Using Structured Light

  • Lee, Oon-Kyu;Kim, Min-Young;Cho, Hyung-Suck;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.123.5-123
    • /
    • 2001
  • For autonomous navigation of the mobile robots, the robots' capability to recognize 3D environment is necessary. In this paper, an on-line 3D map building method for autonomous mobile robots is proposed. To get range data on the environment, we use a sensor system which is composed of a structured light and a CCD camera based on optimal triangulation. The structured laser is projected as a horizontal strip on the scene. The sensor system can rotate$\pm$30$^{\circ}$ with a goniometer. Scanning the system, we get the laser strip image for the environments and update planes composing the environment by some image processing steps. From the laser strip on the captured image, we find a center point of each column, and make line segments through blobbing these center points. Then, the planes of the environments are updated. These steps are done on-line in scanning phase. With the proposed method, we can efficiently get a 3D map about the structured environment.

  • PDF

Scanning Electron Microscopic Study of the Sertoli Cell Processes in the Rat (쥐 Sertoli 세포돌기의 주사전자현미경적 연구)

  • 박영석;이성호;권건오
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.3
    • /
    • pp.245-252
    • /
    • 1998
  • The three-dimensional structure of the Sertoli cell in the rat was investigated by scanning electron microscopy. Morphologically, seven types of Sertoli cell processes were evident : Shrot, flat and ramified processes are projected from the lateral side of the basal portion of Sertoli cell. Leaf-like processes are attached to the surface of spermatocytes and spermatids. Slender cord-like processes, flat and irregular shaped processes, sucker-like processes and club-like processes are observated in the middle and apical portion of seminiferous epithelium. The sheet-like processes rest upon more than one-thirds of the surface of each spermatogonium, spermatocyes and spermatids located in the proximity of the Sertoli cell. All Sertoli processes are originated from Sertoli cell column. Just before spermiation, the processes which are attached to the head of maturation spermatid are eliminated. Though the mechanism for elimination of residual body is not known, these observations segget that the Sertoli cell process are thought to have a reciprocity with the germ cells.

  • PDF

Preparation and Characteristics of Poly(m-phenyleneisophthalamide)/Poly Amic Acid Blended Film (m-Aramid/PAA 블렌딩 필름의 제조 및 특성)

  • Jisu Lee;Ayoung Jang;Ji Eun Gwon;Seung Woo Lee;Sang Oh Lee;Jaewoong Lee
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.221-230
    • /
    • 2023
  • Meta-aramid and polyamic acid were separated and the manufactured films were analyzed for their integration and logarithmic properties. The miscibility of meta-aramid and polyamic acid was analyzed by Fourier transform infrared spectroscopy and scanning electron microscopy. Using calorimetric analysis and differential scanning calorimetry, the storage of meta-aramid and polyamic acid, indicated on the right side of the column, was analyzed. It was confirmed that the initial thermal resistance occurs because the polyamic acid is accounted for in the meta-aramid, and the glass transition temperature and persistence phenomenon are explained.

Fe0/C-bentonite alginate beads and oyster shell fixed-bed column combined process to continuously remove N-acetyl-p-aminophenol in persulfate system

  • Wang, Bing-huang;Zhang, Qian;Honga, Jun-ming
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.301-311
    • /
    • 2018
  • In this study, the ion-gelation method was applied to fabricate novel Fe-carbon-bentonite-alginate beads ($Fe^0$/C-BABs). $Fe^0$/C-BABs could effectively control Fe release during persulfate (PS) activation in N-acetyl-p-aminophenol (APAP) oxidation. A novel two-stage approach that combined $Fe^0$/C-BABs and an oyster-shell-filled bed (OSFB) column was developed to address the low pH and high Fe concentration of the effluent of the traditional PS process. The application of the $Fe^0$/C-BABs and OSFB column regulated pH levels and Fe release during the advanced oxidation of APAP. The characteristics of $Fe^0$/C-BABs were also investigated through scanning electron microscopy, energy dispersive spectrometry, and Fourier transform infrared spectroscopy. The long-term operation performance of $Fe^0$/C-BABs in a continuous fixed-bed reactor under simultaneous PS and APAP feeding was also evaluated. The effects of initial PS concentration, pH, fixed-bed weight, in-flow rate, and dissolved oxygen (DO) were investigated. Under selected conditions, 86.3% efficiency was achieved during the first stage of APAP degradation (effluent pH of 3.05, Fe contents: $106.25mgL^{-1}$). Water quality improved after the effluent was passed through the OSFB column (effluent pH of 6.32, Fe contents: $21.43mgL^{-1}$). Moreover, this study analyzed the free radicals and intermediates produced during APAP degradation to identify the possible routes of APAP degradation.

A Study on Design and Analysis for Magnetic Lenses of a Scanning Electron Microscope using Finite Element Method (유한요소법을 사용한 주사전자 현미경의 전자렌즈 설계 및 해석에 관한 연구)

  • Park, Keun;Jung, Hyun-Woo;Park, Man-Jin;Kim, Dong-Hwan;Jang, Dong-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.95-102
    • /
    • 2007
  • The scanning electron microscope (SEM) is one of the most popular instruments available for the measurement and analysis of the micro/nano structures. It is equipped with an electron optical system that consists of an electron beam source, magnetic lenses, apertures, deflection coils, and a detector. The magnetic lenses playa role in refracting electron beams to obtain a focused spot using the magnetic field driven by an electric current from a coil. A SEM column usually contains two condenser lenses and an objective lens. The condenser lenses generate a magnetic field that forces the electron beams to form crossovers at desired locations. The objective lens then focuses the electron beams on the specimen. The present work concerns finite element analysis for the electron magnetic lenses so as to analyze their magnetic characteristics. To improve the performance of the magnetic lenses, the effect of the excitation current and pole-piece design on the amount of resulting magnetic fields and their peak locations are analyzed through the finite element analysis.