• 제목/요약/키워드: Column extraction

검색결과 761건 처리시간 0.04초

Optimized Design of Dioxin Analysis for Water Sample

  • Choi, Jaewon;Lee, Jaehee;Kim, Kyoungsim;Kim, Sunheong;Bae, Kyunghee
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.219-229
    • /
    • 2005
  • The analytical methods for dioxins in water sample from wastewater to tap water were reviewed. For extraction method, liquid-liquid extraction (LLE) has been widely used, however, this process needs too much time and man power. New approach including solid phase extraction (SPE) is now applicable to large volume of water sample with high extraction efficiency. Column clean up in classical analytical methods were very complex and time consuming procedures during decade. Modifications were tried to decrease solvent and reagents volume. Moreover, use of column connection method has been demonstrated in the environmental matrices. Instrumental configurations also have been improved, in which GC/MS/MS with large volume injection approach can analyze picogram levels. Absolute sensitivities of HRMS increased compared to old versions of double focusing sector type mass spectrometers. Based on these analytical evolutions during last 10 years, we tried to optimize the analytical method for dioxins in water sample from sample extraction to instrumental analysis.

대황(Rheum undulatum L.)으로부터 항주름성 Elastase 저해제의 추출 및 특성 (Extraction and Characterization of an Anti-wrinkle Elastase Inhibitor from Rheum undulatum L.)

  • 이재원;이지수;이종수
    • 한국식품영양학회지
    • /
    • 제21권2호
    • /
    • pp.143-147
    • /
    • 2008
  • To develop a new anti-wrinkle agent from medicinal plants, this study investigated the optimal conditions for extracting elastase inhibitor from Rheum undulatum L. Maximal extraction occurred by using 70% methanol at $50^{\circ}C$ for 24 hr; the elastase inhibitory activity was 60.4%($IC_{50}:6.7{\times}10^3{\mu}g/m{\ell}$). Systematic solvent extraction, thin layer chromatography, silica gel column chromatography, Sephadex LH-20 column chromatography, and reverse-phase high performance liquid chromatography were used in the partial purification of the elastase inhibitor. The compound was soluble in dimethylsulfoxide, methanol, and ethanol, and had maximum absorption spectra at 231.5 nm and 275.5 nm.

커플드칼럼크로마토그래피에 의한 사람 혈장 중 테르부탈린의 정량 (Determination of terbutaline in human plasma by coupled column chromatography)

  • 고미영;전상설;김경호
    • 분석과학
    • /
    • 제28권2호
    • /
    • pp.125-131
    • /
    • 2015
  • 사람혈장 중 베타투 수용체 작용약 테르부탈린의 정량법을 개발하고 밸리데이션을 실시하였다. 혈장시료를 Sep-pak 실리카를 이용하여 고상추출한 후 HPLC로 측정하였다. C18 칼럼을 사용하여 혈장 중의 방해물질로부터 테르부탈린 분획을 분리하여 실리카칼럼으로 보내어 테르부탈린과 내부표준물질을 분리 정량하였다. 두 칼럼은 짧은 실리카 전칼럼이 달린 절환밸부로 연결하여 사용하였다. C18 칼럼의 이동상에 녹아있는 테르부탈린의 분획은 전칼럼에서 농축되어 실리카칼럼으로 보내지고 형광 여기파장 276 nm와 들뜸파장 306 nm로 측정하였다. 이 분석법은 여섯 명의 혈장에서 특이성이 있음을 확인하였다. 혈장 중 테르부탈린 0.4-20.0 ng/mL 농도범위에서 상관계수 0.9999로 양호한 직선성을 나타내었다. 정량한계농도는 0.4 ng/mL 농도로 정밀도가 10.1% 를 나타내었다.

Extraction Methods of Organic Components from Rubber Composites and Analysis of the Extract Using Gas Chromatography/Mass Spectrometry

  • Chae, Eunji;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제54권3호
    • /
    • pp.188-200
    • /
    • 2019
  • Rubber articles contain various organic additives such as antidegradants, curing agents, and processing aids. It is important to extract and analyze these organic additives. In this paper, various extraction methods of organic additives present in rubber composites were introduced (solvent extraction, Soxhlet extraction, headspace extraction, and solid-phase microextraction), and the extracts were characterized using gas chromatography/mass spectrometry (GC/MS). Solvent and Soxhlet extractions are easy-to-perform and commonly used methods. Efficiency of solvent extraction varies according to the type of solvent used and the extraction conditions. Soxhlet extraction requires a large volume of solvent. Headspace sampling is suitable for extracting volatile organic compounds, while solid-phase extraction is suitable for extracting specific chemicals. GC/MS is generally used for characterizing the extract of a rubber composite because most components of the extract are volatile and have low molecular weights. Identification methods of chemical structures of the components separated by GC column were also introduced.

Extraction and separation of glabridin from licorice by reversed phase high performance liquid chromatography

  • Choi, Du Young;Row, Kyung Ho
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.455-459
    • /
    • 2006
  • The extraction and separation of glabridin from licorice root by HPLC was performed in this work. First, by investigating the different extraction solvents, extraction methods and extraction times, a one-hour ultrasonic extraction procedure with ethyl acetate as the extraction solvent was optimized. Then the ethyl acetate extraction was applied to RP-HPLC for separation of glabridin. The column efficiencies and resolutions were experimentally investigated with different mobile phase compositions. Baseline separation of glabridin was obtained under the mobile phase composition of 50/50 vol.% (ACN/water). The retention time of glabridin was 20.3 min. The peak of glabridin was collected from the HPLC elution for several times and identified by LC/MS. Under the optimum extraction and HPLC separation methods, 1.26 g of glabridin per kg licorice root could be extracted.

Determination of Terbutaline Enantiomers in Human Plasma by Coupled Achiral-Chiral High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Kim, Hyun-Ju;Hong, Seon-Pyo;Shin, Sang-Deok
    • Archives of Pharmacal Research
    • /
    • 제23권5호
    • /
    • pp.441-445
    • /
    • 2000
  • Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column, The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/$m\ell$ (r=0.9999) and detection limit was 1.0 ng/$m\ell$ .

  • PDF

A Direction-Based Vascular Pattern Extraction Algorithm for Hand Vascular Pattern Verification

  • Im, Sang-Kyun;Choi, Hwan-Soo;Kim, Soo-Won
    • ETRI Journal
    • /
    • 제25권2호
    • /
    • pp.101-108
    • /
    • 2003
  • This paper proposes an improved vascular pattern extraction algorithm for person verification applications. The proposed direction-based vascular pattern extraction (DBVPE) algorithm is based on the directional information of vascular patterns. It applies two different filters to the input images: row vascular pattern extraction filter (RVPEF) for effective extraction of the abscissa vascular patterns and column vascular pattern extraction filter (CVPEF) for effective extraction of the ordinate vascular patterns. We use the combined output of both filters to obtain the final hand vascular patterns. Unlike the conventional hand vascular pattern extraction algorithm, the directional extraction approach prevents loss of the vascular pattern connectivity. To validate the DBVPE algorithm, we used a prototype system with a DSP processor. The prototype system shows approximately a three-times better false acceptance rate (FAR) than the conventional single filter algorithm.

  • PDF

Comparison of Static and Dynamic Solvent Extraction of Polychlorinated Dibenzofurans from Fly Ash

  • Yang, Jeong Soo;Jeong, Jang Hwan;Yu, Euy Kyung
    • 분석과학
    • /
    • 제17권4호
    • /
    • pp.295-301
    • /
    • 2004
  • In this study, static and dynamic solvent extractions are compared for more efficient extraction of polychlorinated dibenzofurans (PCDFs) from fly ash. Static solvent extraction rather than dynamic extraction showed a higher recovery of PCDFs, which was adsorbed strongly with fly ash. The effects of parameters, such as temperature, toluene-isopropyl alcohol mixture, static and dynamic time flow rate, and solvent volume on the extraction were investigated and the variations in average recoveries of PCDFs were explained. In both extractions, temperature was an effective parameter because the higher temperature gave the higher recoveries. In dynamic solvent extraction, dynamic time was more effective than flow rate and solvent volume for the extraction of PCDFs from fly ash. Multi-layer column chromatography on neutral and acidic silica gel with n-hexane was used for cleaning up the extracts. The quantification of the PCDFs extracted was performed using HPLC-UV.

고정식 진동수주형 파력 발전장치의 챔버 유동 및 파에너지 변환효율 해석 (Numerical Analysis of Chamber Flow and Wave Energy Conversion Efficiency of a Bottom-mounted Oscillating Water Column Wave Power Device)

  • 구원철;김무현;최윤락
    • 대한조선학회논문집
    • /
    • 제47권3호
    • /
    • pp.388-397
    • /
    • 2010
  • A two-dimensional time-domain, potential-theory-based fully nonlinear numerical wave tank (NWT) was developed by using boundary element method and the mixed Eulerian-Lagrangian (MEL) approach for free-surface node treatment. The NWT was applied to prediction of primary wave energy conversion efficiency of a bottom-mounted oscillating water column (OWC) wave power device. The nonlinear free-surface condition inside the chamber was specially devised to represent the pneumatic pressure due to airflow velocity and viscous energy loss at the chamber entrance due to wave column motion. The newly developed NWT technique was verified through comparison with given experimental results. The maximum energy extraction was estimated with various chamber-air duct volume ratios.