• Title/Summary/Keyword: Column Type

Search Result 1,207, Processing Time 0.027 seconds

The Characteristics of Size by Classification of Worship-Space Types in the Central Hall of Buddhist Temple (사찰 주불전의 예불공간 유형에 따른 규모 특성)

  • Jo, Woo-Ju;Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.3
    • /
    • pp.83-90
    • /
    • 2011
  • The purpose of this study is to analyze size and proportion of plan and section, and derive characteristics by types of worship-space in central hall of buddhist temple. This study covers 45 buddhist temples as designated national treasure and treasure. Types of central hall of buddhist temple are 'Columnless Type', 'Inner Column Type', and 'Colonnade Type'. The results are as follows. Firstly, in the proportion of width and length, 'Columnless Type' is mostly represented with 1:0.73, 'Inner Column Type' with 1:0.54 and seems to be widening for the other types, and 'Colonnade Type' is same proportion with 'Columnless Type'. Secondly, in the proportion of width and height, 'Columnless Type' is 1:0.61 and sizes of worship-space of this type are different but the proportion is same. In the 'Inner Column Type', worship-space is enlarged because a buddhist altar is hustled into the rear. Thirdly, in the proportion of length and height, all types are represented with similar proportion as 1:1. Finally, proportion of the volume of worship-space in 'Columnless Type' is 1(width):0.74(length):0.60(height). The case of 'Inner Column Type' is 1:0.57:0.57 and length of worship-space is shortened, so characteristics of horizontality is emphasized. The space of same size with the proportion of 'Columnless Type' is situated in the inside of worship-space in 'Colonnade Type'.

Behavior Evaluation on the Non-symmetric Composite Column for Unit Modular Frames (모듈러 골조용 비대칭 기둥-보 접합부에 대한 거동 평가)

  • Park, Keum-Sung;Lee, Sang-Sup;Bae, Kyug-Woong;Moon, Ji-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.36-44
    • /
    • 2019
  • The purpose of this study is to evaluate the structural performance of press-formed type asymmetric column to beam connections of steel-PC composite module frames. Most of the column sections of the joints making up the modular frame use a closed square steel section. The column-beam connection using the closed column section has difficulty in reducing the workability and securing the fire resistance. In order to overcome this disadvantage, concrete is filled in the asymmetrical open type cross section of the steel plate by press forming. A total of four specimens were fabricated to investigate the structural performance of press formed type asymmetric column to beam connections. The experimental results show that the structural performance and behavior of the asymmetric columns are different depending on whether the asymmetric column cross section is composited or the column width thickness ratio. The structural performance of the press formed type asymmetric column to beam connection was evaluated by comparing the experimental results with the theoretical formulas.

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

A Study on the Dynamic Behavior Characteristics of Steel Column Base using Energy Absorbtion High Strength Bolt (에너지 흡수형 고력볼트를 사용한 철골 주각부의 동적 거동 특성에 관한 연구)

  • Lee, Seung-Jae;Park, Jae-Seong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.3
    • /
    • pp.67-76
    • /
    • 2011
  • Column base is very important part of steel structure because it transmits load to foundation in structure. Column base which is used frame construction in the inside and outside of the country is distributed into exposed-type, concrete encased and imbeded-type. Exposed-type column base is most profitable, if consider reuse and recycle of elements first of all. In this study, we proposed a new style exposed-type column base improved in performance for construction work and mechanical performance.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

Simplified Bending Moment Analysis in Slab Bridges supported by Column Type Piers (기둥으로 지지된 슬래브교(橋)의 모멘트 산정(算定)에 관한 연구(硏究))

  • Kim, Young Ihn;Lee, Chae Gyu;Kim, Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.17-24
    • /
    • 1992
  • It would be much effective that single column type pier is used in concrete slab bridges rather than ${\Pi}$ or gravity type pire is used. To determine the longitudinal benging moment in concrete slab bridges supported by single column type piers, the concept of effective width is applied. By elastic plate theory cooperated with finite element method, the distribution of the longitudinal moment of the slab supported by single column type piers is studied. The main variables are span, width. thickness of the slab, and column section size. The analytical results obtained are summarized and analysed to evaluate the maximum longitudinal negative moment, then a simplified method for calculating the longitudinal moment is proposed.

  • PDF

An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns (프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구)

  • Choi, Seung-Won;Shin, Hyun-Mok;Lee, Jae-Hoon;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

Evaluation of Axial Behavior of Strengthened Columns according to Different Peripheral Closed Hoops in Jacket Section (확대단면에서 폐쇄형 외부 띠철근 배근 방법에 따른 보강기둥의 중심축하중 거동 평가)

  • Hwang, Yong-Ha;Yang, Keun-Hyeok;Sim, Jae-Il;Choi, Yong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.139-146
    • /
    • 2019
  • This study examined the effect of various arrangement methods for forming peripheral closed hoops in the jacket section on the axial behavior of section enlargement strengthening columns. Four types of peripheral closed hoops arranged in the jacket section were prepared as follows: 1) Closed connection of prefabricated bar units (column P); 2) V-clip installation across the overlapped legs of channel-type bars (column V); 3) Use of glass fiber mesh for an alternative of steel bars (column F); and 4) combination of prefabricated bar units and glass fiber mesh (column PF). The V-clip is designed to form the closed hoops in the jacket section using the overlapped channel-type bars, preventing the opening of the channel bar legs. The glass fiber mesh is to examine the feasibility to apply for closed hoops in the jacket section as an alternative for steel bars, considering the easy construction. In the jacket section of all the strengthened columns, V-ties were arranged for supplementary ties, avoiding the interruption of the existing column. The axial stiffness and strength of the strengthened columns were insignificantly affected by the arrangement methods of closed hoops in the jacket section. The axial ductility ratio of the strengthened columns P, V, and PF was enhanced more than twice of that measured in the non-seismic existing column. However, the column F exhibited a lower ductility than the other strengthened columns because of the fracture of the mesh at the ultimate strength of the column. The V-clip approach was favorable to enhance the ductility of the strengthened column, preventing the opening of the legs of channel-type bars.

Continuous Rapid Fermentation of Soy Sauce by Immobilized Zygosaccharomyces rouxii BH-90 and Candida versatilis BH-91 Using Column Type Reactor (고정화된 Zygosaccharomyces rouxii BH-90과 Candida versatilis BH-90를 이용한 Column 형 reactor 에서 간장의 연속적 속성발효)

  • Ryu, Beung-Ho;Cho, Kyung-Ja;Chae, Young-Ju;Jin, Seung-Heun
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.4
    • /
    • pp.366-372
    • /
    • 1993
  • The aim of this study was to find out the rapid fermentation of soy sauce from koji hydrolyzate using column type reactor packed with immobilized yeast cells. Each immobilized cell of Zygosaccharomyces rouxii BH-90 and Candida versatilis BH-91 in the packed column type reactor produced 2.8% ethyl alcohol and 18mg/l 4-ethylguaiacol over 96 hours under the optimal condition. Continuous fermentation was performed by immobilized Z. rouxii BH-90 packed in column type reactor. Immobilized Z. rouxii BH-90 produced 2.30~2.85% ethyl alcohol during 30 days, and decreased gradually from 40 days to 80 days. Also C. versatilis BH-91 produced 4-ethylguaiacol at the constant rate of 16~18mg/l and decreased gradually after 40 days. Final product of soy sauce contained 2.8% ethyl alcohol and 18mg/l 4-ethylguaiacol. However, amino acid compositions of final products were consisted of predominantly glutamic acid, leucine, arginine, aspartic acid, lysine and valine, which were more than 50% of total amino acid.

  • PDF