• Title/Summary/Keyword: Column Test

Search Result 2,171, Processing Time 0.033 seconds

Effect of Core Reinforcement Ratio to PC Wide Girder-Column Joint (PC 넓은 보$\cdot$기둥 접합부에서 코어 철근비의 영향)

  • Song Han-Beom;Kang Dae-Eon;Yang Won-Jik;Yi Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.123-126
    • /
    • 2005
  • The purpose of this study is to evaluate a effect of core reinforcement ratio to PC wide girder-column joint. Three half scale subassemblies were representing a portion of a protype structure were design, constructed, and tested to failure. From the test result, girder-column width ratio play an important role in the improvement of strength and ductility.

  • PDF

Flexural Test on Beam-Column Connections Using High Strength Concrete and GFRP bars (고강도 콘크리트와 GFRP 보강근을 사용한 보-기둥 접합부 휨 실험)

  • Lee, Hye-Jin;Kim, Si-Jun;Yang, Keun-Hyeok;Park, Sang-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.177-178
    • /
    • 2017
  • The beam-column connection using high-strength GFRP bars exhibited a comparable flexural strength but brittle failure mode, when compared with those of connection using high-strength steel reinforcement.

  • PDF

Welding and Moment Resisting Performance of R/C Column-Steel Girder Connection (철근콘크리트 기둥-철골 보 접합부의 용접성능 및 휨 저항성능)

  • 전재범;최광호;이세웅;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.553-558
    • /
    • 1999
  • As a process of development of composite beam-column connection system, structural tests have been conducted to verify moment resisting performance of the system. The tests have been proceeded by two steps, the first being welding performance test of the steel connection rod and stiffners, and the second overall moment resisting capacity of the fuly assembled system. Ten welding test specimens and four prototype specimens have been used in the test. Good structural performance of welding test specimens has been observed without any single welding failure, and sufficient moment resisting capacity has been proved from the overall performance test, with the moment magnitude in excess of the calculated plastic moment.

  • PDF

Stiffness Reduction Factor for Flat Plate Slabs (플랫 플레이트 슬래브 해석을 위한 강성감소계수 제안)

  • Park, Young-Mi;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.337-340
    • /
    • 2006
  • The purpose of this study is to propose the stiffness reduction factor for flat plate slabs under lateral loads. Current design code (e.g., ACI 318-05) requires considering the effects of cracks for calculating slab stiffness under lateral loads. This study collected the test results of 20 interior slab-column connections, from which stiffness reduction in each test was estimated with respect to the ratio of applied moment to cracking moment ($M_a/M_{cr}$). Based on collected data, this study proposed equations for calculating stiffness reduction with respect to $M_a/M_{cr}$. To verify the proposed equations, this study conducted the experimental test of interior slab-column connections under quasi-static cyclic loading. From the test, load-deformation curve is compared to that obtained from effective beam width method with the proposed equation for the stiffness reduction. It is shown that the effective beam width method with the proposed equation for stiffness reduction predicts accurately the test results.

  • PDF

An Experimental Study on Characteristics of Sedimentation of Dredged Soil (준설토의 침강특성에 관한 실험적연구)

  • Yoo, Nam-Jae;Lee, Jong-Ho;Jun, Sang-Hyun;Lee, Jong-yong
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.113-122
    • /
    • 2000
  • Column tests in the laboratory were preformed to investigate characteristics of settling process of dredged soil sampled from in-situ. Test results were analyzed by using the existing theories on discrete settling and hindered settling. From column tests of monitoring the interface with time, settling was found to be a linear process with time and the settling rate was increased with initial water content of slurry. The settling rate was also observed to decrease with increasing initial height of slurry. Most of settling process were composed of flocculation, hindered settling and self-weight consolidation. On the other hands, flocculation of soil during settling was observed and it was found that the size and density of flocculated particles could be analyzed by using the method proposed by Richardson and Zaki.

  • PDF

Experimental Study on Secondary Moment of High-Strength RC Slender Columns under Eccentric Loads (편심을 받는 고강도콘크리트 장주의 2차모멘트에 관한 실험적 연구)

  • 박동규;배성용;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.571-576
    • /
    • 1998
  • This paper is a part of a research plan aimed at the verification of basic design rules of high-strength concrete columns. A total of 19 slender column specimens were tested to measure secondary moment and stiffness of eccentrically loaded reinforced concrete tied columns. Main variables included in this test program were concrete compressive strength, steel amount, eccentricity, and slenderness ratio. The concrete compressive strength varied from 356kg/$\textrm{cm}^2$ to 951kg/$\textrm{cm}^2$, the longitudinal steel ratios were between 1.13% and 5.51%, and slenderness ratios were 40 and 61. Calculated moment magnification factors and column stiffness based on design codes are higher than the test results for high axial load under small eccentricity, for higher slenderness ratio, for lower longitudinal steel ratio, and for high-strength concrete. The moment magnification method of the current design codes may provide a very conservative design for high-strength concrete slender column.

  • PDF

An Experimental Study III on the Bolted Connection between H-Beam and Precast-Concrete Column (PC 기둥-H형강보의 볼트접합부에관한 실험적 연구III)

  • Yeo, In-Seok;Park, Soon-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.307-310
    • /
    • 2005
  • The PCS system, which consists of precast concrete column and steel beam, has been under development. Experimental test has been carried out to investigate the structural performance of the system under earthquake. Two types of test specimens of beam-column joints are designed in order to compare the performances. One is the system with reinforced concrete slab and the other is without slab. It is found that the system with slab could satisfy all of the requirements from ACI Criteria such as strength, stiffness degradation and energy dissipation capacity except initial stiffness. It is also investigated that the stiffness of the joint is belong to rigid joint type according to Bjorhovde criterion. And it is observed that the partial-composite system between beam and slab is more effective than full-composite system in the respect of the energy dissipation capacity of the system.

  • PDF

Inelastic analysis of RC beam-column subassemblages under various loading histories

  • You, Young-Chan;Yi, Waon-Ho;Lee, Li-Hyung
    • Structural Engineering and Mechanics
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1999
  • The purpose of this study is to propose an analytical model for the simulation of the hysteretic behavior of RC (reinforced concrete) beam-column subassemblages under various loading histories. The discrete line element with inelastic rotational springs is adopted to model the different locations of the plastic hinging zone. The hysteresis model can be adopted for a dynamic two-dimensional inelastic analysis of RC frame structures. From the analysis of test results it is found that the stiffness deterioration caused by inelastic loading can be simulated with a function of basic pinching coefficients, ductility ratio and yield strength ratio of members. A new strength degradation coefficient is proposed to simulate the inelastic behavior of members as a function of the transverse steel spacing and section aspect ratio. The energy dissipation capacities calculated using the proposed model show a good agreement with test results within errors of 27%.

An Experimental Study for Development of Details and Design Method of CFT Column-to-RC Flat Plate Connections (CFT기둥 철근콘크리트무량판 접합부 상세 및 설계법 개발을 위한 실험연구)

  • Lee, Cheol-Ho;Kim, Jin-Won;Lee, Jin-Hyeok;Park, Cheol-Su;Oh, Jeong-Gun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.203-210
    • /
    • 2005
  • This paper summarizes full-scale test results on CFT column to flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building practice due to its various structural and construction advantages. Constructing the floor as flat plate is often regarded as being essential for both cost savings and rapid construction. However, efficient details for CFT column to flat plate connections have not been proposed yet, and their development is urgently needed. Based on some strategies that include maximizing economical field construction, several connecting schemes were proposed and tested in this study. Test results showed the proposed connection details can exhibit strength and stiffness comparable to or greater than those of R/C flat plate counterpart.

  • PDF

A Solution to Large Strain Resonant Column and Torsional Shear Tests Apparatus (대변형율 시험을 위한 공진주/비틂전단 시험기의 해결방안)

  • Bae, Yoon-Shin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3C
    • /
    • pp.103-108
    • /
    • 2011
  • In this study, the limitations of large strain resonant column and torsional shear tests apparatus are described and solutions to the limitations are also described. The limitations are rotational distance, limited torque, and measurable deformation system, respectively. To resolve the rotational distance, the bottom platen was modified. And the four-armed drive plate was modified into eight-armed drive plate and the drive coil connection was changed to obtain powerful torque.