• 제목/요약/키워드: Color shade

검색결과 290건 처리시간 0.02초

도재 소성 횟수가 색조변화에 미치는 영향 (The effects on the color change of dental porcelain due to repeated firing)

  • 김욱태;박창근
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.33-39
    • /
    • 2008
  • Recently natural characteristics and esthetics have been interested increasing in clinical dentistry. Thus the evaluation of the shade of dental porcelain has become an important part in dental research. Noritake Super Porcelain EX-3 Vita shade A2 (Noritake, Japan) Vintage HaLo Vita shade A2 (Shofu, Japan), Vita omega 900 Vitapan 3D-master shade 2M2 (Vita, Germany) were conducted for six times for repeated firing in a way to observe the change of color with respect to the number of firing. The repeated firing was implemented with the vacuum firing and air firing, and by using Shade Eye-EX Chroma meter (Shofu, U.S.A.), the changes in values of shade, value and chroma were compared. With the above results, the change of color was not noticed only in Vita when repeated firing was applied.

  • PDF

2종의 측색기에 의한 도재 색조 재현의 정확성 비교 (Comparison on accuracy of porcelain color reproducibility using two colorimeters)

  • 이태일;안진수;김영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.348-355
    • /
    • 2009
  • 연구 목적: ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan)와 Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany)의 도재색조 재현의 정확성을 비교연구하여 보고자 함이다. 연구 재료 및 방법: ShadeEye-Ncc dental chroma meter와 Shadepilot$^{TM}$ system을 사용하여 Vitapan 3D Master shade guide의 2M2와 3M2 shade tap.을 측색하고, 이 자료를 통하여 shade guide tap. 형태로 도재시편을 제작한다. 시편제작 시 사용하는 porcelain system은 ShadeEye-Ncc dental chroma meter는 Vintage Halo Porcelain system을, Shadepilot$^{TM}$ system은 VitaOmega900 Porcelain system을 사용한다. 모델인 shade tap.과 제작된 도재시편을 spectrophotometer로 측색하고, 그 결과를 토대로하여 ${\Delta}E$를 계산하여, 두 측색기의 정확성을 비교검증하였다. 결과: 1. Shadepilot$^{TM}$ system이 ShadeEye-Ncc dental chroma meter에 비하여 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 2. 모델인 Shade tap.의 shade에 따라서 도재색조 재현성에 차이를 나타내었다. 2M2 shade tap.에 비하여 3M2 shade tap.에서 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 3. 두 측색기 모두에서 제작된 도재시편의 ${\Delta}E$가 평균4.44-6.14로 육안으로 구분 가능한 정도의 색조차이를 보였다. 결론: Shadepilot$^{TM}$ system이 비교적 더 정확한 도재색조 재현성을 나타낸다고 할 수 있으며, ShadeEye-Ncc dental chroma meter를 사용할 때는 치아 전체의 여러부분에서 측색을 하여 정확성을 높이는 것이 필요하리라 생각된다.

Color discrepancy of single-shade composites at different distances from the interface measured using cell phone images

  • Marcia Luciana Carregosa Santana;Gabriella de Jesus Santos Livi;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.7.1-7.11
    • /
    • 2024
  • Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

Working Clothes Design and Production in the Mechatronics Machinery Industry with the Application of Faber Birren's Color Harmony Theory

  • Park, Hye-Won;Yang, Jung-Hee
    • 패션비즈니스
    • /
    • 제16권3호
    • /
    • pp.32-44
    • /
    • 2012
  • This study proposed a color scheme that is harmonious with the working environment of industrial sites using Birren's color harmony theory for color planning. To apply the Birren's color harmony theory to working clothes, the basic colors were chosen, and six of the eight harmony formulas of Birren excluding achromatic colors (white + grey + black) and solid color harmony (solid colors + white + black) were used to form a palette for each case. For the basic colors, the color chips of four dominant colors (yellow-green, sky-blue, blue, and violet), which were chosen from a field survey for preferences in the first step, and the production of materials in the second step were collected through the PANTONE color chips. The selected color chips were PANTONE 13-0550 TPX, PANTONE 15-4105 TPX, PANTONE 18-3949 TPX, and PANTONE 19-3720 TPX. These color chips were scanned and their RGB values were extracted through Photoshop CS. Then the colors were arranged in accordance with the Birren's color harmony formulas (Color+Tint+White, Color+Shade+Black, Tint+Tone+Shade, Shade+Tone+Black, Shade+Tone+White, and Tint+Shade+Tone+Gray). In addition, the proposed palette color schemes were applied through Birren's color harmony formulas using Texpro V 10.1 textile to the schematization of working clothes that were designed in the previous study. Palette formation in line with Birren's color harmony formulas provided scientific color arrangement results. Visually presenting the color scheme of working clothes will help the color selection of working clothes in tune with the circumstances of industrial sites.

열가압 및 열처리에 따른 IPS Empress 2 Glass-Ceramic의 색 안정성 (Color Stability of IPS Empress 2 Glass-Ceramic after Heat-Pressing and Heat-Treatments)

  • 송기범;이상권;김유리;오상천
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.93-99
    • /
    • 2002
  • This study was performed to investigate the color stability of IPS Empress 2 glass-ceramic after heat-pressing and/or heat-treatments. Three types of IPS Empress 2 ingots (shade 100, 300, 500) were tested. For this study, three groups were prepared as follows: group 1 is as-received material, group 2 is heat-pressed material, and group 3 is fully heat -treated material. The color of the specimens was measured with a colorimeter. The data were statistically evaluated with one-way ANOVA and Scheffe's multiple test. The results obtained were as follows: 1. IPS Empress 2 glass-ceramic demonstrated less color stability according as the shade is lighter. Namely, the shade 500 showed the lowest color shifts and the shade 100 showed the greatest color shifts after heat-pressing and heat-treatments. 2. In the cases of shade 100 and 300, the changes of ${\Delta}E^*$ were affected mostly by the changes of $L^*$ and $b^*$. 3. In ${\Delta}E^*$ of the shade 100, there were significant differences among the group 1, 2, and 3 (P<0.001). 4. In ${\Delta}E^*$ of the shade 300, there were significant differences between the group 1 and 2, and the group 1 and 3 (P<0.001). 5. In ${\Delta}E^*$ of the shade 500, there was significant difference only between the group 1 and 3 (P<0.001).

ShadeScan$^{TM}$ System을 이용한 인공치의 색조분석 (SHADE ANALYSIS OF ARTIFICIAL TEETH USING SHADE $SCAN^{TM}$ SYSTEM)

  • 성채련;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.443-457
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze and estimate whether each company may produce the color of artificial teeth as it stands, in the standard of vita classical shade guide using ShadeScan$^{TM}$ System. Material and methods: we chose the products of 6 companies -EFUCERA, IVOCLAR, ENDURA, TRUBYTE, DURADENT, and DURACROSS- estimated the shade value of each fixed point(cervical, body, and incisal area) of artificial tooth, and verified the equality among the samples from the same company. Results: First, the variation appeared significant at cervical and incisal area. It means that there were significant differences between cervical and incisal area although the most similar artificial teeth to the patients’natural teeth were provided. Second, the results in the body area showed that the variation between artificial and natural teeth was finite(p<0.05) in that area. Conclusion: it shows that the reproduction of colors of artificial teeth might be successful regarding the body is the most important part for a determination of the color of artificial teeth. However, more complements are necessary for the better reproduction of the color of artificial teeth between cervical and incisal area.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

20대 대학생들의 상악중절치 색조와 구강보건 및 식습관 관련 특성 (Oral health and eating habits characteristics relating to maxillary central incisor color of the university students in their twenties)

  • 이지영;윤영숙
    • 한국치위생학회지
    • /
    • 제12권2호
    • /
    • pp.261-273
    • /
    • 2012
  • Objectives : This study aims to prepare the basic data of the teeth color by measuring tooth mode using the color of the maxillary central incisor of the college students in their twenties as the dental colorimeter, and oral health and eating habit characteristics were examined. Methods : The maxillary central incisor(1 teeth) of the subjects of study as 467 students(male 89, female 378) was measured during the period from November 14, December 2 2011, so the color of total 467 teeth were examined, and oral health and eating habit characteristics were researched. Results : 1. As the results of measurement of the shade, value, hue of maxillary central incisor by the general characteristics of the subject, the major(shipbuilding information, special rehabilitation for young children) was higher at 3.3 of the shade, and the grade(1), age($$\geq_-20$$), major(beauty culture & cosmetic, occupational therapy) showed higher at +2 of the value, and the grade(1) and all major showed higher at R3 of the hue. 2. As the results of measurement of the shade, value, hue of maxillary central incisor by the oral health characteristics, the subjective teeth color(yellow) and the education of oral health(no) showed higher at 2.5 of the shade. 3. As the results of measurement of the shade, value, hue of maxillary central incisor by the eating habit characteristics of the subjects, the chocolate showed higher at 3.0 and 2.0 of the shade, and the red pepper paste showed higher at +2 and STD of the value, and the green tea showed higher at $R_3$ of the hue. Conclusions : This study demonstrates that the color of the maxillary central incisor showed differences various tendency according to the oral health and eating habit characteristics.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.