• Title/Summary/Keyword: Color reproducibility

Search Result 78, Processing Time 0.025 seconds

THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY (수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가)

  • Kim Lee-Kyoung;Cho In-Ho;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

Realization of the national standard of candela traceable to the absolute cryogenic radiometer at KRISS (극저온 절대복사계에 소급한 칸델라 국가표준 실현)

  • Park, Seung-Nam;Kim, Yong-Wan;Lee, Dong-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.443-448
    • /
    • 2004
  • We realized the national standard of the candela, one of the SI units, by using two photometers with the spectral responsivity measured in reference to the absolute cryogenic radiometer. The external apertures of the photometers were fabricated using a diamond turning machine, and measured in terms of area with uncertainty of 0.05 %(k = 1). The candela is realized using a 1 kW FEL lamp and the characterized photometers on an optical bench. The uncertainty is budgeted to be 0.25 %(k = 1) considering the uncertainty of the spectral responsivity and the response uniformity of the detectors, the area of the external apertures, the color temperature of the lamp, and the positioning reproducibility of the photometers and the lamp. We verified the realized scale by comparing with the scale of National Institute of Standards and Technology, USA. They coincided with each other within 0.1%.

Recognition Direction Improvement of Target Object for Machine Vision based Automatic Inspection (머신비전 자동검사를 위한 대상객체의 인식방향성 개선)

  • Hong, Seung-Beom;Hong, Seung-Woo;Lee, Kyou-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1384-1390
    • /
    • 2019
  • This paper proposes a technological solution for improving the recognition direction of target objects for automatic vision inspection by machine vision. This paper proposes a technological solution for improving the recognition direction of target objects for automatic vision inspection by machine vision. This enables the automatic machine vision inspection to detect the image of the inspection object regardless of the position and orientation of the object, eliminating the need for a separate inspection jig and improving the automation level of the inspection process. This study develops the technology and method that can be applied to the wire harness manufacturing process as the inspection object and present the result of real system. The results of the system implementation was evaluated by the accredited institution. This includes successful measurement in the accuracy, detection recognition, reproducibility and positioning success rate, and achievement the goal in ten kinds of color discrimination ability, inspection time within one second and four automatic mode setting, etc.

High-Sensitive Fiber-Optic pH Sensor Using Neutral Red Immobilized in Porous Sol-Gel Film (뉴트럴레드가 고정화된 다공성 졸-겔 필름을 이용한 고감도 광섬유 pH 센서의 특성)

  • Jeon, Da-Yeong;Yoo, Wook-Jae;Shin, Sang-Hun;Han, Ki-Tek;Park, Jang-Yeon;Park, Byung-Gi;Cho, Seung-Hyun;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.223-228
    • /
    • 2012
  • In this study, a fiber-optic pH sensor based on a pH sol-gel film is fabricated. The sol-gel film is made by co-polymerizing tetramethoxysilane, trimethoxymethylsilane, ethanol and distilled water. As a pH indicator, a neutral red is immobilized in a thin porous film formed by the sol-gel process. The pH change in a sensing probe gives rise to a change in the color of the pH sol-gel film, and the absorbance of reflected light through the pH sol-gel film is also changed. By using a spectrometer, therefore, the spectra of reflected lights in the sensing probe with different pH values are measured. Also, the relationships between the pH values and the absorbance are analyzed on the basis of the color variations of the pH sol-gel films. In repeated experiments, the fiber-optic pH sensor shows that it has reversibility, a high reproducibility and a wide absorbance change in a pH range from pH 5 to 9. Also, we confirmed that the fabricated pH sol-gel film exhibits a fast response time, little or no pH indicator leaching and a dynamic range of 2.04 dB from pH 5 to 9. Based on the results of this study, a fiber-optic pH sensor can be developed for the pH monitoring in the harsh environments.

Monitoring the Change of Physical Properties of Traditional Dancheong Pigments (전통 단청안료 표면의 물리적 특성 변화 모니터링)

  • Kim, Ji Sun;Jeong, Hye Young;Byun, Doo-Jin;Yoo, Min Jae;Kim, Myoung Nam;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.549-561
    • /
    • 2020
  • This study aimed to assess the performance and life of nine natural mineral dancheong pigments: Seokganju, Jinsa, Hwangto, Jahwang, Wunghwang, Seokrok, Noerok, Seokcheong, and Baekto. The design of the accelerated weathering test considered the domestic climate characteristics and the location of Dancheong. Outdoor weathering tests were conducted at the Research Institute in Daejeon and the Sungnyemun Gate in Seoul to confirm the field reproducibility of the accelerated weathering test. Monitoring of the physical changes in pigments through accelerated and outdoor weathering tests are based on ultraviolet exposure dose. Despite small cracks at the beginning of the tests, the monitoring showed that Seokganju and Baekto had no marked physical changes, but the surface cracks of Jinsa and Seorok continue to expand. Hwangto and Noerok were marked with water or were resin stained, and the particles of Jahwang, Wunghwang, and Seokcheong had lost their luster. Despite the absolute difference in color change in each test, the final chromaticity change patterns of pigments were similar in that the color difference between Baekto and Noerok was below five, and Jina was above 28. The physical and surface color pigment changes were more concentrated in outdoor weathering tests than in accelerated tests, and the Seoul site was more intense than the Daejeon site. This is because outdoor weathering tests are exposed to severe variations of temperature and moisture or deposition of dust particles and, in the case of Seoul, the site is more exposed to the external environment than the Daejeon site.

Inter- and Intra-rater Reliability of Pattern Identification Using Nasal Endoscopy for Allergic Rhinitis (비내시경을 활용한 알레르기 비염에 대한 한의학적 변증 지표의 관찰자간, 관찰자내 신뢰도 연구)

  • Kim, Kyu-Seok;Yun, Young-Hee;Park, Jeong-Su;Kim, Nam-Kwen;Kim, Kyung-Jun;Kim, Hee-Taek;Hong, Seung-Ug;Jang, Bo-Hyeong;Yoon, Hwa-Jung;Choi, In-Hwa;Ko, Seong-Gyu
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.26 no.2
    • /
    • pp.10-18
    • /
    • 2013
  • Objectives : We performed a pilot study to investigate inter- and intra-rater reliability of pattern identification using nasal endoscopy for allergic rhinitis(AR). Methods : Eight experts of ophthalmology, otolaryngology and dermatology of Korean medicine evaluated 20 nasal endoscopy photograph cases of AR patients with pattern identification index using nasal endoscopy for AR including the nasal membrane color(pale / hyperemia), nasal membrane humidity(dryness / dampness), rhinorrhea(watery / yellow), and membrane edema (atrophic / edematous) on nasal endoscopy. Results : Intra-rater agreement(%) and Kappa coefficient was generally from 'moderate' to 'good'(% agreement: 73.13-90% / Kappa coefficient: 0.547-0.748). Inter-rater agreement(%) and Kappa coefficient was also from 'moderate' to 'good' (% agreement: 65-85% / Kappa: 0.475-0.778) except 'humidity(dryness / dampness)' item (% agreement: 55.98% / Kappa: 0.340). In findings of subgroup analysis according to affiliation of raters, Inter-rater agreement(%) and Kappa coefficient of raters in same affiliation was higher than inter-rater agreement(%) and Kappa coefficient of raters in different affiliation except 'dryness / dampness' item. Conclusions : It is necessary to improve objectivity and reproducibility of pattern identification using nasal endoscopy for allergic rhinitis(AR) through the development of detail-oriented criteria and enhanced training of clinicians with development of standard operating procedures(SOPs).

New Miniature Phalaenopsis 'Snow Angel' Having White Flower with Pink Lip as Pot Flower (백색에 분홍립 소형의 분화용 팔레놉시스 'Snow Angel' 육성)

  • Joung, Hyang Young;Lee, Young Ran;Kim, Mi Seon;Lim, Jin Hee;Shin, Hak Ki;Rhee, Hae Kyung;Park, Sang Kun
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.3
    • /
    • pp.168-171
    • /
    • 2011
  • 'Snow Angel' was developed by National Institute of Horticultural & Herbal Science in 2008. A cross was made between phalaenopsis '0361', a white and red lip small-medium variety, and Phalaenopsis 'S98PN1', a white and dark pink lip small-medium variety with pink net pattern. The seedling materials were cultivated to 83 seedling lines from 2000 to 2002. The white and pink lip small-phalaenopsis '99-0404-13' with flowers of round shape was selected by individual selection. The selected line was multiplicated and the growth characteristics were investigated for the first characteristic trial from 2003 to 2007. It was named as 'Wonkyo F2-18' in 2008 and investigated for the second characteristic trial of growth characteristics. The examination was executed for stability, uniformity, yearly reproducibility, and public fancy. It was selected as a high quality cultivar with excellent flower shape and flower color from the selection council of new cultivars for agricultural products, there after it was registered as 'Snow Angel' in 2008.

Application of Terrestrial LiDAR for Reconstructing 3D Images of Fault Trench Sites and Web-based Visualization Platform for Large Point Clouds (지상 라이다를 활용한 트렌치 단층 단면 3차원 영상 생성과 웹 기반 대용량 점군 자료 가시화 플랫폼 활용 사례)

  • Lee, Byung Woo;Kim, Seung-Sep
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.177-186
    • /
    • 2021
  • For disaster management and mitigation of earthquakes in Korea Peninsula, active fault investigation has been conducted for the past 5 years. In particular, investigation of sediment-covered active faults integrates geomorphological analysis on airborne LiDAR data, surface geological survey, and geophysical exploration, and unearths subsurface active faults by trench survey. However, the fault traces revealed by trench surveys are only available for investigation during a limited time and restored to the previous condition. Thus, the geological data describing the fault trench sites remain as the qualitative data in terms of research articles and reports. To extend the limitations due to temporal nature of geological studies, we utilized a terrestrial LiDAR to produce 3D point clouds for the fault trench sites and restored them in a digital space. The terrestrial LiDAR scanning was conducted at two trench sites located near the Yangsan Fault and acquired amplitude and reflectance from the surveyed area as well as color information by combining photogrammetry with the LiDAR system. The scanned data were merged to form the 3D point clouds having the average geometric error of 0.003 m, which exhibited the sufficient accuracy to restore the details of the surveyed trench sites. However, we found more post-processing on the scanned data would be necessary because the amplitudes and reflectances of the point clouds varied depending on the scan positions and the colors of the trench surfaces were captured differently depending on the light exposures available at the time. Such point clouds are pretty large in size and visualized through a limited set of softwares, which limits data sharing among researchers. As an alternative, we suggested Potree, an open-source web-based platform, to visualize the point clouds of the trench sites. In this study, as a result, we identified that terrestrial LiDAR data can be practical to increase reproducibility of geological field studies and easily accessible by researchers and students in Earth Sciences.