• Title/Summary/Keyword: Color Channel Analysis

Search Result 58, Processing Time 0.025 seconds

Deltoid Middle Fiber of the Isometric Contraction According to Elastic Band and Dumbbell on Various Shoulder Abduction Angle (탄력밴드와 아령에 의한 저항이 다양한 어깨관절 외전 각도에서 중간 어깨 세모근의 등척성 수축에 미치는 영향)

  • Park, Min-Chull;Lee, Sang-Yeol
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.71-76
    • /
    • 2016
  • PURPOSE: The purpose of this study was to compare isometric contraction of deltoid middle fiber between elastic band and light dumbbell on various shoulder abduction angle. And this study intends to examine the compare with isometric contraction on deltoid middle fiber in various abduction angle of shoulder joint. METHODS: The participants of this study were Korean healthy adult in their 20s (n=60). The 8 channel surface electromyography was used to measure activity of the deltoid middle fiber at isomeric contraction on various abduction angle: $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$ of shoulder joint using elastic band: red color Theraband and dumbbell: 2kg. The data used in the analysis of the present study was the root mean square. RESULTS: The deltoid middle fiber activation was not significantly different between elastic band and dumbbell at each abduction angle. The deltoid middle fiber activation significantly increased as more to increased shoulder abduction angle in elastic band and dumbbell. CONCLUSION: The elastic band and dumbbell was to provide the similarly load to the deltoid middle fiber isometric contraction on all of the shoulder abduction angle. The deltoid middle fiber activation increased as more to increased shoulder abduction angle in elastic band and dumbbell. These results may be an important reference in development of exercise on shoulder joint.

Shopping behavior, attitude and characteristics of internet clothing shoppers (인터넷 의류구매자의 의류쇼핑행동, 태도 및 특성)

  • 하오선;신혜원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.71-82
    • /
    • 2001
  • In this study, Internet users were separated into 3 groups(clothing shoppers, clothing non-shoppers, non-shoppers). Shopping behavior of clothing shoppers(those who used the internet channel for clothing shopping) and the attitude to internet clothing shopping were examined. And characteristics of clothing shoppers were compared with characteristics of clothing non-shoppers(those who purchased goods except clothing on internet) and non-shoppers(those who purchased nothing on internet). The reason why clothing non-shoppers and non-shoppers didnt purchase clothing on internet was also investigated. Questionaire was used as method of gathering data. Mean, ANOVA, Duncan-test, t-test and $\chi$$^2$-test were used for data analysis. 1. Clothing shoppers considered carefully design, exchange & refund, quality and price and purchased generally T-shirt, underwear, jeans and sports wear. 2. Clothing shoppers thought clothing in internet shopping malls was not various in item, design, color, size and price. But they were satisfied with shopping convenience. 3. Clothing shoppers were more conscious of the shopping cost compared with clothing non-shoppers and non-shoppers Recreational shopping orientations and fashion leader orientations were low in both groups. Self-confidence in connection with clothing purchase were high in each groups, but that of clothing shoppers were relatively higher than clothing non-shoppers and non-shoppers. 4. The reason why clothing non-shoppers and non-shoppers didnt purchase clothing in internet shopping malls was that they wanted to buy after trying on clothing in a store, didnt believe the quality of clothing, didnt need to purchase clothing in internet shopping malls, and worried about exchange & refund.

  • PDF

A Study on the Encapsulation of Cosmetic Emulsion Using Microfluidics (Microfluidics를 이용한 화장품 에멀젼 캡슐레이션에 대한 연구)

  • Jeong, Nam-Gyun;Jin, Hong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.81-86
    • /
    • 2021
  • The cosmetic industry is technology-intensive in the field of fine chemistry and continues to grow globally. The functional aspects have been mainly emphasized in the past to increase the market share in these cosmetics industries. Recently, however, efforts have been made to attract the attention of consumers to the visual effects as well as the excellent performance of cosmetics at home and abroad. Accordingly, cosmetic manufacturers are trying various technologies that encapsulate the cosmetic emulsion and modify the shape, color, and texture of the emulsion capsule. The basic and easiest method of encapsulating emulsion is dropping the emulsion through the nozzle from emulsion storage. On the other hand, the existing method of encapsulating emulsion has a limit in reducing the size of the capsule. In this study, the limit was shown by theory and numerical analysis method, and the emulsion encapsulation phenomena occurring in the micro-channel were studied to apply microfluidics as an alternative.

MLCNN-COV: A multilabel convolutional neural network-based framework to identify negative COVID medicine responses from the chemical three-dimensional conformer

  • Pranab Das;Dilwar Hussain Mazumder
    • ETRI Journal
    • /
    • v.46 no.2
    • /
    • pp.290-306
    • /
    • 2024
  • To treat the novel COronaVIrus Disease (COVID), comparatively fewer medicines have been approved. Due to the global pandemic status of COVID, several medicines are being developed to treat patients. The modern COVID medicines development process has various challenges, including predicting and detecting hazardous COVID medicine responses. Moreover, correctly predicting harmful COVID medicine reactions is essential for health safety. Significant developments in computational models in medicine development can make it possible to identify adverse COVID medicine reactions. Since the beginning of the COVID pandemic, there has been significant demand for developing COVID medicines. Therefore, this paper presents the transferlearning methodology and a multilabel convolutional neural network for COVID (MLCNN-COV) medicines development model to identify negative responses of COVID medicines. For analysis, a framework is proposed with five multilabel transfer-learning models, namely, MobileNetv2, ResNet50, VGG19, DenseNet201, and Inceptionv3, and an MLCNN-COV model is designed with an image augmentation (IA) technique and validated through experiments on the image of three-dimensional chemical conformer of 17 number of COVID medicines. The RGB color channel is utilized to represent the feature of the image, and image features are extracted by employing the Convolution2D and MaxPooling2D layer. The findings of the current MLCNN-COV are promising, and it can identify individual adverse reactions of medicines, with the accuracy ranging from 88.24% to 100%, which outperformed the transfer-learning model's performance. It shows that three-dimensional conformers adequately identify negative COVID medicine responses.

A Study on Image Analysis of Graphene Oxide Using Optical Microscopy (광학 현미경을 이용한 산화 그래핀 이미지 분석 조건에 관한 연구)

  • Lee, Yu-Jin;Kim, Na-Ri;Yoon, Sang-Su;Oh, Youngsuk;Lee, Jea Uk;Lee, Wonoh
    • Composites Research
    • /
    • v.27 no.5
    • /
    • pp.183-189
    • /
    • 2014
  • Experimental considerations have been performed to obtain the clear optical microscopic images of graphene oxide which are useful to probe its quality and morphological information such as a shape, a size, and a thickness. In this study, we investigated the contrast enhancement of the optical images of graphene oxide after hydrazine vapor reduction on a Si substrate coated with a 300 nm-thick $SiO_2$ dielectric layer. Also, a green-filtered light source gave higher contrast images comparing to optical images under standard white light. Furthermore, it was found that a image channel separation technique can be an alternative to simply identify the morphological information of graphene oxide, where red, green, and blue color values are separated at each pixels of the optical image. The approaches performed in this study can be helpful to set up a simple and easy protocol for the morphological identification of graphene oxide using a conventional optical microscope instead of a scanning electron microscopy or an atomic force microscopy.

Detection for Region of Volcanic Ash Fall Deposits Using NIR Channels of the GOCI (GOCI 근적외선 채널을 활용한 화산재 퇴적지역 탐지)

  • Sun, Jongsun;Lee, Won-Jin;Park, Sun-Cheon;Lee, Duk Kee
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_4
    • /
    • pp.1519-1529
    • /
    • 2018
  • The volcanic ash can spread out over hundreds of kilometers in case of large volcanic eruption. The deposition of volcanic ash may induce damages in urban area and transportation facilities. In order to respond volcanic hazard, it is necessary to estimate efficiently the diffusion area of volcanic ash. The purpose of this study is to compare in-situ volcanic deposition and satellite images of the volcanic eruption case. In this study, we used Near-Infrared (NIR) channels 7 and 8 of Geostationary Ocean Color Imager (GOCI) images for Mt. Aso eruption in 16:40 (UTC) on October 7, 2016. To estimate deposit area clearly, we applied Principal Component Analysis (PCA) and a series of morphology filtering (Eroded, Opening, Dilation, and Closing), respectively. In addition, we compared the field data from the Japan Meteorological Agency (JMA) report about Aso volcano eruption in 2016. From the results, we could extract volcanic ash deposition area of about $380km^2$. In the traditional method, ash deposition area was estimated by human activity such as direct measurement and hearsay evidence, which are inefficient and time consuming effort. Our results inferred that satellite imagery is one of the powerful tools for surface change mapping in case of large volcanic eruption.

Fabrication of 3D Paper-based Analytical Device Using Double-Sided Imprinting Method for Metal Ion Detection (양면 인쇄법을 이용한 중금속 검출용 3D 종이 기반 분석장치 제작)

  • Jinsol, Choi;Heon-Ho, Jeong
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.323-330
    • /
    • 2022
  • Microfluidic paper-based analytical devices (μPADs) have recently been in the spotlight for their applicability in point-of-care diagnostics and environmental material detection. This study presents a double-sided printing method for fabricating 3D-μPADs, providing simple and cost effective metal ion detection. The design of the 3D-μPAD was made into an acryl stamp by laser cutting and then coating it with a thin layer of PDMS using the spin-coating method. This fabricated stamp was used to form the 3D structure of the hydrophobic barrier through a double-sided contact printing method. The fabrication of the 3D hydrophobic barrier within a single sheet was optimized by controlling the spin-coating rate, reagent ratio and contacting time. The optimal conditions were found by analyzing the area change of the PDMS hydrophobic barrier and hydrophilic channel using ink with chromatography paper. Using the fabricated 3D-μPAD under optimized conditions, Ni2+, Cu2+, Hg2+, and pH were detected at different concentrations and displayed with color intensity in grayscale for quantitative analysis using ImageJ. This study demonstrated that a 3D-μPAD biosensor can be applied to detect metal ions without special analysis equipment. This 3D-μPAD provides a highly portable and rapid on-site monitoring platform for detecting multiple heavy metal ions with extremely high repeatability, which is useful for resource-limited areas and developing countries.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF