• 제목/요약/키워드: Collimator

검색결과 494건 처리시간 0.024초

흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정 (Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry)

  • 서영민;강신일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

HYPERSPECTRAL IMAGING SPECTROMETER WITH A NOVEL ZOOMING FUNCTION

  • Choi Jin;Kim Tae Hyung;Kong Hong Jin;Lee Jong-Ung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.213-216
    • /
    • 2005
  • A novel hyperspectral imaging spectrometer controlling spatial and spectral resolution individually has been proposed. This imaging spectrometer uses a zoom lens as a telescope and a focusing element. It can change the spatial resolution fixing the spectral resolution or the spectral resolution fixing the spatial resolution. Here, we report the concept of the hyperspectral imaging spectrometer with the novel zooming function and the optical design of a zoom lens as the focusing element. By using lens module and third-order aberration theory, we have presented the initial design of four-group zoom lens with external entrance pupil. And the optimized zoom lens with a focal length of 50 to 150 mm is obtained from the initial design by the optical design software. As a result, the designed zoom lens shows satisfactory performances in wavelength range of 450 to 900 nm as a focusing element in an imaging spectrometer. Furthermore, the collimator lens of the imaging spectrometer is designed through the third-order aberration correction by using an iterative process.

  • PDF

BEAM 몬테칼로 코드를 이용한 Siemens Primus 선형가속기 다엽콜리메이터의 모델링 예비연구 (Preliminary Study of the Siemens Primus Linac MLC modelling using BEAM Monte Carlo code)

  • 정광호;서태석;조병철;박성호
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.29-32
    • /
    • 2004
  • 본 연구에서는 방사선치료장치의 몬테칼로 시뮬레이션에 널리 이용되는 BEAM 코드를 이용하여 Siemens사의 Primus 선형가속기 다엽콜리메이터(MLC)를 모델링한 후 그 적합성을 측정 데이터와의 비교를 통하여 검증하였다. 모델링을 위해 Primus 선형가속기의 다엽콜리메이터의 치수를 실측하였고 근사화를 통해 VARMLC 모듈을 사용하여 모델링하였다. 모델링 시에 leakage 및 tongue-and-groove 효과를 고려하였다. 시뮬레이션 결과는 필름 측정 결과와 잘 일치함을 확인하였으며, 본 연구에서의 방법이 Siemens 사의 다엽콜리메이터의 모델링에 유효함을 확인할 수 있었다.

  • PDF

Optical Design of the DOTIFS Spectrograph

  • 정하은
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.100.2-100.2
    • /
    • 2014
  • The DOTIFS is a new multi-object Integral Field Spectrograph (IFS) planned to be designed and built by the Inter-University Center for Astronomy and Astrophysics, Pune, India, (IUCAA) for cassegrain side port of the 3.6m Devasthal Optical Telescope (DOT) being constructed by the Aryabhatta Research Institute of Observational Sciences, Nainital. (ARIES) It is a multi-integral field unit (IFU) spectrograph which has 370-740nm wavelength coverage with spectral resolution R~1200-2400. Sixteen IFUs with microlens arrays and fibers can be deployed on 8 arcmin field. Each IFU has $8.7^{{\prime}{\prime}}{\times}7.4^{{\prime}{\prime}}$ field of view with 144 spaxel elements. 2304 fibers coming from IFUs are dispersed by eight identical spectrographs with all refractive and all spherical optics. In this work, we show optical design of the DOTIFS spectrograph. Expected performance and result of tolerance and thermal analysis are also shown. The optics is comprised of f=520mm collimator, broadband filter, dispersion element and f=195mm camera. Pupil size is determined as 130mm from spectral resolution and budget requirements. To maintain good transmission down to 370nm, calcium fluoride elements and high transmission optical glasses have been used. Volume Phase Holographic grating is selected as a dispersion element to maximize the grating efficiency and to minimize the size of the optics. Detailed optics design report had been documented. The design was finalized through optical design review and now ready for order optics.

  • PDF

Optimization of CORVUS Planning System with PRIMART Linac for Intensity Modulated Radiation Therapy

  • Lee, Se-Byeong;Jino Bak;Cho, Kwang-Hwan;Chu, Sung-sil;Lee, Suk;Suh, Chang-ok
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.83-85
    • /
    • 2002
  • Yonsei Cancer Center introduced an IMRT System at the beginning of February, 2002. The system consists of CORVUS(NOMOS) inverse planning machine, LANTIS(SIEMENS), PRIMEVIEW and PRIMART Linac(SIEMENS). The optimization of CORVUS planning system with PRIMART is an important work to get an efficient treatment plan. So, we studied two Finite Size Pencil Beams, 1.0 x 1.0 cm$^2$ and 0.5 x 1.0 cm$^2$, and four leaf transmission sets, 5%, 10%, 20%, 33%. We compared the dose distribution of target volume and delivery efficiency of the plan results.

  • PDF

Development of Electronic Portal Imaging Device and Treatment Position Verification for Fractionated Stereotatic Radiotherapy

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Chilgoo Byun;Hong, Seung-Hong;Rhee, Soo-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.446-449
    • /
    • 2002
  • The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.

  • PDF

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

코발트-60의 조사야(照射野) 변형(變形) 및 반음영(半陰影) 차폐(遮蔽)효과에 따른 선량분포(線量分布)에 관한 연구(硏究) (A Study on the Dose Distribution of Various Field and Penumbra Shield in the Telecobalt-60)

  • 김영일;이혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.71-72
    • /
    • 1985
  • This study was performed on the dose distribution of various field size and the effect of penumbra shield in the telecobalt unit. The results obtained are as follows. 1. Errors of the light and ${\gamma}-ray$ field size was below the regulation as 0.52 percentage. 2. The coefficient of field area was increased with the larger field area, and this coefficient was showed the more difference in larger SSD. 3. The rectangular field areas, which were described by level of the same percentage depth does, were decreased with the more elongation factor. At the same elongation factor, the compensating factor was decreased with the larger field size. 4. The lead block or extension collimator was able to shield r-ray exposure of outside field size from 50 to 80 percentage. 5. On the matching adjacent fields, while the gap between beam edges are contacted, that overlapped beam edges indicated up to 140 percentage, and while the gap was 1 cm, it could be reduced to 90 Percentage. The lead-libocking on the overlapped area was more effective to lower dose, as 80 percentage in this case. 6. Percentage depth dose of various trimming field sizes were increased linearlly according to area 1 perimeter size, but the center split field size did not maintain linearlly.

  • PDF

원자력병원(原子力病院) 싸이클로트론 중성자선(中性子線) 치료실(治療室)의 방사선(放射線) 방어(防禦)에 관한 총합적(總合的) 평가(評價) (Compositional Qualification of Radiation Protection in Neutron Radiotherapy Room with KCCH Cyclotron)

  • 유성열;조철구;고경환
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.45-50
    • /
    • 1989
  • 원자력병원 싸이클로트른 중성자선(中性子線) 치료실의 방사선 준위(準位)를 측정함으로써 방사선 안전도를 검토하여 보았다. 중성자선 치료실내 방사선 노출은 주로 isocentric gantry에 내장된 중성자선 표적(標的)과 조사야(照射野)를 결정하는 collimator의 방사화(放射化)로 인한 잔류방사능(殘留放射能) (remanent radioactivity)에 의해 결정 된다. 측정결과 선량율(線量率)은 과다하지 않았고 개인 집적선량(集積線量)도 허용치 이내였다. 방사선 작업종사자로서의 의료기사는 환자치료 시 매 조사(照射) 완료 직후부터 5분간 멸살(滅殺)시간을 갖도록 조치하였다.

  • PDF

치료중 실시간 모니터링을 위한 투과형 빔측정장치 개발

  • 김재홍;;;박연수;양태건
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.315-315
    • /
    • 2010
  • 양성자 빔을 이용하여 두경부 암 치료를 South Africa의 iTHEMBA에서 시행하고 있다. 200 MeV의 양성자 빔라인으로부터 진공에서 대기로 인출하여 노즐을 통과하여 종양세포에 조사된다. 치료계획에 적합하게 빔에너지와 모양을 변환하고, 빔을 모니터링하는 기계적 장치들이 노즐에 구성된다. 빔라인에는 이온챔버, Steering Magnet, Multi-wire 이온챔버, Range trimmer plates, lead scattering plate, Double-wedge energy degrader, Multi-layer Faraday cup, Range modulator, Range monitor, occluding ring, Shielding collimators, Quadrant and monitor ionization chamber, Treatment collimator, 그리고 Wellhofer dosimetry tank로 구성되어 있다. 총길이는 6.6m이며 노즐 끝에서 환자의 isocenter 까지는 30cm 정도 아래에 위치한다. 상기의 배치를 갖는 시스템의 양성자 scattering system의 성능을 MCNPX v2.5.0 Monte Carlo simulation을 실시하였다. 또한 정확한 선량을 실시간으로 측정하는 방법인 투과형 검출기를 개발하여 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF