• Title/Summary/Keyword: Collector System

Search Result 538, Processing Time 0.023 seconds

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 -)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

A Study on the Evaluation of a Scattering Dust Collector in Vehicle-Induced Wind and Brake Caliper Locations (자동차 주행풍과 브레이크 캘리퍼 위치에 따른 비산먼지 포집기의 특성연구)

  • Son, Byeong-Rea;Ahn, Jun-Hyung;Lee, Young-Hwan;Hwang, Young-Kug
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.43-48
    • /
    • 2022
  • A scattering dust collector in automobile brake pads was investigated in this study. The dust scattering was measured by mounting a booth with a particle counter for both the vehicle-induced wind and brake caliper locations. In addition, the collection effect of the dust scattering was analyzed using the designed dust collector. The results of this study can be used to develop an advanced dust collector and the field test modes for dust scattering in an automotive brake system.

Performance Prediction of a Solar Power System with Stirling Engine (Matching Collector/Receiver with Engine/Generator Systems) (스털링엔진 태양열 발전시스템의 성능예측(집열기.수열기 및 엔진.발전기 시스템의 조화))

  • Bae, Myung-Whan;Chang, Hyung-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.794-799
    • /
    • 2001
  • The simulation analyses of a solar power system with monolithic concentrator by using a stirling engine are carried out to predict the system performance in four test sites. The site has different intensities and distributions of direct solar radiation respectively. Seoul, Pusan and Cheju in Korea, and Naha in Japan are selected as test sites. To accomplish the same demand of a 25 kW output that the power level of a system has, it needs to take the matching of collector/receiver with engine/generator systems. In such a case, also, the size of the collector is sometimes adjusted. In this study, the diameter of the collector is decided by using the solar radiation of design point, which is defined as the sum of average and standard deviation $\sigma$ of maximum direct solar radiation distribution for a day during a year in the respective test site. It is found that the average power output during the system operating time in the case of slope error ${\sigma}_s=2.5$ is within the range of 9 to 13 kW.

  • PDF

Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors (태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가)

  • Ko, Myeong-Jin;Lim, Bo-Min;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

An Experimental Study on Thermal and Electrical Performance of an Air-type PVT Collector (실험에 의한 공기식 PVT 컬렉터의 열·전기 성능에 관한 연구)

  • Kim, Sang-Myung;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.23-32
    • /
    • 2019
  • PVT (Photovoltaic/thermal) system is technology that combines PV and solar thermal collector to produce and use both solar heat and electricity. PVT has the advantage that the energy production per unit area is higher than any single use of PV or solar thermal energy systems because it can produce and use heat and electricity simultaneously. Air-type PVT collectors use air as the heat transfer medium, and the air flow rate and flow pattern are important factors affecting the performance of the PVT collector. In this study, a new air-type PVT collector with improved thermal performance was designed and manufactured. And then thermal and electrical performance and characteristics of air-type PVT collector were analyzed through experiments. For the thermal performance analysis of the PVT collector, the experiment was conducted under the test conditions of ISO 9806:2017 and the electrical performance was analyzed under the same conditions. As a result, the thermal efficiency increased to 26~45% as the inlet flow rate of PVT collector increased from $60{\sim}200m^3/h$. Also, it was confirmed that the air-type PVT collector prevents the PV surface temperature rise according to the operating conditions.

Study on Analysis and Evaluation of Performance for Evacuated Tubular Solar Collector System (진공관형 태양열 집열장치의 성능평가 및 해석 연구)

  • Chun, Tae-Kyu;Ahn, Young-Chull
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.112-119
    • /
    • 2013
  • The thermal performance for test system with evacuated tubular solar collector is experimentally investigated to obtain the basis data for developing new type solar collector. For this purpose, the test system was designed using CATIA and then after being manufactured, the system was tested using evacuated tubular solar collector. Numerical analysis, furthermore, was performed using ANSYS Fluent V.13 for glass evacuated tubular solar collector. The results showed that as setting temperature difference(${\Delta}T$) of system was increased, total operating(working) time was almost same in all cases, even though operating count was decreased. The results of numerical analysis showed that as temperature of solar absorber in glass evacuated tubular solar collector was high, the drop-rate of temperature of center part was increased.

Implementation of RF Monitoring System for the Dust Collector in Industrial Environments (산업 환경에서의 집진기에 대한 RF모니터링 시스템 구현)

  • Lee, Sung-Yeob;Lee, Kwang-Hee;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.513-517
    • /
    • 2014
  • In this study, we implemented and designed an RF monitoring system to manage a dust collector wirelessly, which is manually operated. The dust collector prevents the emission of air pollutants and improves air condition. It is possible to implement a high-value monitoring system of a dust collector, the system will wirelessly monitor many important data such as the operating time, the amount of electricity consumption, and the differential pressure value of a large number of the dust collectors in an industrial site, the system also displays and saves these data on a manager's PC, and when an error occurs, the system sends the error message to a manager's mobile phone. Therefore, through the RF monitoring system implemented in this paper, it is possible to reduce unnecessary loss for recording information of each dust collector to stack emission management system (SEMS).

A garbage collector design and implementation for flash memory file system (플래시 메모리 파일 시스템을 위한 가비지 콜렉터 설계 및 구현)

  • Kim, Ki-Young;Son, Sung-Hoon;Shin, Dong-Ha
    • The KIPS Transactions:PartA
    • /
    • v.14A no.1 s.105
    • /
    • pp.39-46
    • /
    • 2007
  • Recently flash memory is widely accepted as a storage devise of embedded systems for portability and performance reasons. Flash memory has many distinguishing features compared to legacy magnetic disks. Especially, a file system for flash memory usually assumes the form of log-structured file system and it employs garbage collector accordingly. Since the garbage collector can greatly affect the performance of file system, it should be designed carefully considering flash memory features. In this paper, we suggest a new garbage collector for existing JFFS2 (Journaling Flash File System II) file system. By extensive performance evaluation, we show that the proposed garbage collector achieves improved performance in terms of flash memory consumption rate, increased flash memory life time, and improved wear-leveling.

Performance Analysis of Solar Heating System for High Solar Fraction using TRNSYS (태양열 온수급탕 시스템의 TRNSYS 열성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.59-67
    • /
    • 2012
  • In this paper, performances of solar hot water supply systems are parametrically analyzed with the variations of solar collector area, slope of collector and volume of storage. All simulations are conducted by using TRNSYS computer program. Average solar fractions, collector efficiencies and temperatures of storage are investigated monthly as well as annually. For system analysis, the maximum value of monthly average solar fractions has a limitation of 90 percent. As a result, the designed solar thermal system with $6m^2$ collector area, $50^{\circ}$ slope and $0.36m^2$ storage volume could provide almost an annual average solar fraction of 72 percent. By increasing the storage volume to $0.42m^2$, the annual solar fraction of system increases up to 73 percent.

Improvement of the Performance of Solar Cooling Heating Systems(I) - Dynamic Load Calculation Using TRNSYS and an Optimization of Solar Systems - (태양열에 의한 냉방 및 난방시스템의 성능향상(I) - TRNSYS에 의한 동직열부하 계산과 태양열 시스템의 최적화 -)

  • Kang, Y.T.;Kim, H.K.;Ro, S.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.696-707
    • /
    • 1988
  • This study simulates a typical solar system using the transient simulation program TRNSYS, and calculates the maximum cooling load of the model room of $50m^2$. In this study, energy rate control method is used in calculating a maximum cooling load. On the ground of the maximum cooling load of the model room, the variables that have an effect on the solar collection performance of the solar system are made a selection. Also in this study the trend of the solar collection performance is shown as the variables change. The results show that the variables which have an effect on the collection performance are collector area, collector mass flow rate, collector slope and the volume of storage tank, and the optimal value of Ac/Vt is not constant but varies as the collector area and the collector mass flow rate. Also the results show that for cooling system the optimal value of the collector slope is latitude minus $15^{\circ}$ during the seasonal operations, and twenty percent of the maximum cooling load is saved with the aid of the solar energy.

  • PDF