• 제목/요약/키워드: Collection time

검색결과 2,288건 처리시간 0.031초

Signal Generation Due to Alpha Particle in Hydrogenated Amorphous Silicon Radiation Detectors

  • Kim, Ho-Kyung;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.397-404
    • /
    • 1996
  • The hydrogenated amorphous silicon (a-Si : H) holds good promise for radiation detection from its inherent merits over crystalline counterpart. For the application to alpha spectroscopy, the induced charge collection in a-Si : H pin detector diodes ons simulated based on a relevant non-uniform charge generation model. The simulation was peformed for the initial energy and the range of incident alpha particles, detector thickness and the operational parameters such as the applied reverse bias voltage and shaping time. From the simulation, the total charge collection was strongly affected by hole collection as expected. To get a reasonable signal generation, therefore, the hole collection should be seriously considered for detector operational parameters such as shaping time and reverse voltage etc. For the spectroscopy of alpha particle from common alpha sources, the amorphous silicon should have about 70${\mu}{\textrm}{m}$ thickness.

  • PDF

컴퓨터 포렌식스 지원을 위한 시스템 로그 및 휘발성 정보 수집에 관한 연구 (A Study of System Log and Volatile Information Collection for Computer Forensics)

  • 고은주;오세민;장은겸;이종섭;최용락
    • 정보학연구
    • /
    • 제10권4호
    • /
    • pp.41-56
    • /
    • 2007
  • In Digital Computing Environment, volatile information such as register, cache memory, and network information are hard to make certain of a real-time collection because such volatile information are easily modified or disappeared. Thus, a collection of volatile information is one of important step for computer forensics system on ubiquitous computing. In this paper, we propose a volatile information collection module, which collects variable volatile information of server system based on memory mapping in real-time.

  • PDF

공기 중 Toluene diisocyanates 측정방법에 따른 포집농도 비교 (A Comparison of Collection Concentrations Based on Airborne Toluene Diisocyanates Measurement Methods)

  • 박형성;원종욱;김치년;노재훈
    • 한국산업보건학회지
    • /
    • 제23권4호
    • /
    • pp.341-347
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the differences in airborne TDI concentrations based on the filter collection method and liquid collection method and to compare airborne TDIs concentrations by sampling method change when using the filter collection method in the spray-painting process. Methods: For the sample measurement, the filter collection method(OSHA#42) and liquid collection method(NIOSH#5522) were used; for the sampling method, the full-period single sampling and full-period consecutive sampling methods were used. The samples were collected in spray-painting and drying process locations. Results: In all samples collected from the spray-painting and drying process locations through the filter collection and liquid collection methods, greater amounts of 2,6-TDI than 2,4-TDI were detected. When the TDI collection concentrations based on the sampling methods were compared, the concentrations of 2,4-TDI and 2,6-TDI collected by the consecutive sampling method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the single sampling method for both the filter collection method and liquid collection method used in the spray-painting process. These differences were statistically significant. Conclusions: When TDI collection concentrations based on the sample measurement methods were compared, the concentration of 2,4-TDI and 2,6-TDI collected through the liquid collection method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the filter collection method, and the differences were statistically significant. In the drying process, no difference was shown in the collection concentrations of 2,4-TDI and 2,6-TDI with the two measurement methods.

AUTOMATED DATA COLLECTION TECHNOLOGY APPLICATIONS IN CONSTRUCTION

  • Ronie Navon
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.27-29
    • /
    • 2009
  • Real-time control of on-site construction, based on high quality data, is essential to identify discrepancies between actual and planned performances. Additionally, real-time control enables timely corrective measures to be taken when needed to reduce the damages caused by the discrepancies. The focus of the presentation will be on our work, which uses automated data technologies to collect data needed for real time control.

  • PDF

능동형 RFID 시스템을 위한 인식 슬롯 스캔 기반 태그 수집 알고리즘 (Identified Slot Scan-based Tag Collection Algorithm for Active RFID Systems)

  • 윤원주;정상화;권윤근
    • 한국통신학회논문지
    • /
    • 제35권5B호
    • /
    • pp.753-761
    • /
    • 2010
  • 본 논문에서는 능동형 RFID 시스템에서 태그 수집의 성능을 향상시키기 위한 새로운 태그 수집 알고리즘을 제안한다. 제안하는 알고리즘에서 리더는 인식 슬롯 스캔 과정을 통해 빈 슬롯과 충돌 슬롯의 발생을 검출하고 이들에 의한 시간 낭비를 감소시켜서 태그 수집의 성능을 향상시킨다. 본 논문에서는 실제 환경에서의 실험을 통 해 제안하는 태그 수집 알고리즘의 성능 향상을 평가하기 위해 능동형 RFID 리더와 태그를 구현하였다. 하나의 리더와 60개의 태그를 이용한 실험 결과에서 제안하는 태그 수집 알고리즘은 ISO/IEC 18000-7 표준의 태그 수집 알고리즘에 비해 평균 21.7%의 태그 수집 시간 감소와 평균 28.3%의 인식 처리율 향상을 보였고, 20개의 태그를 대상으로 한 배터리 소모 실험에서는 평균 22.7%의 태그 배터리 소모 감소를 보였다.

Development of Semicontinuous Measurement System of Ionic Species in PM2.5

  • Hong, Sang-Bum;Chang, Won-il;Kang, Chang-Hee;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권7호
    • /
    • pp.1505-1515
    • /
    • 2009
  • A new method to semicontinuously determine $PM_{2.5}$ ionic species with a short time resolution is described in detail. In this system, a particle collection section (mixing part, particle collection chamber, and air/liquid separator) was developed. A Y-type connector was used to mix steam and an air sample. The particle collection chamber was constructed in the form of a helix coil and was cooled by a water circulation system. Particle size growth occurred due to the high relative humidity and water absorbed particles were efficiently collected in it. Liquid samples were drained out with a short residence time (0.08-0.1 s). The air/liquid separator was also newly designed to operate efficiently when the flow rate of the air sample was 16.7 L $min^{-1}$. For better performance, the system was optimized for particle collection efficiency with various types of test aerosols such as ($NH_4)_2SO_4,\;NaCl,\;NH_4HSO_4,\;and\;NH_4NO_3$. The particle collection efficiencies were almost 100% at different concentration levels in the range over 500 nm in diameter but 50-90% in the range of 50-500 nm under the following experimental conditions: 15 coil turns, a water flow rate for steam generation of 0.65 mL $min^{-1}$, and an air sample flow rate of 16.7 L $min^{-1}$. Finally, for atmospheric applications, chemical compositions of $PM_{2.5}$ were determined with a time resolution of 20 min on January 11-24, 2006 in Seoul, Korea, and the chemical characteristics of $PM_{2.5}$ ions were investigated.

디지털 장서개발의 방법과 전략 (Methods and Strategies of Digital Collection Development in Libraries)

  • 윤희윤
    • 한국도서관정보학회지
    • /
    • 제38권2호
    • /
    • pp.79-99
    • /
    • 2007
  • 도서관의 핵심역량은 서고에 축적된 방대한 아날로그 자료와 서버에 농축되는 고품질의 디지털 컨텐츠에서 발원하며, 양자의 상호작용이 강화할 때 지식정보의 타입캡슐과 게이트웨이로서의 정체성을 확보할 수 있다. 이러한 전제 하에 본 연구는 디지털 장서개발의 대상과 방법을 논급한 다음에 전자잡지의 라이선스 확보 인터넷 정보자원의 개발, 기관 레포지터리 구축 등의 전략을 다각도로 제시하였다. 어느 도서관이든 디지털 장서개발과 아카이빙에 소홀하면 정보공유지로서의 입지를 상실할 것이다.

  • PDF

고속전철의 주행조건이 집전계의 동특성에 미치는 영향 (The Effect of Train Motion on Dynamic Characteristics of Current Collection System)

  • 김정수
    • 한국철도학회논문집
    • /
    • 제9권1호
    • /
    • pp.18-22
    • /
    • 2006
  • The dynamic characteristics of the current collection system are investigated by conducting a test run in which signals from accelerometers and load cells attached to the various parts of the pantograph are analyzed in both the time and frequency domains. The dynamic characteristics of the current collection system are found to be strongly influenced by the train speed; the fluctuation in the pantograph motion increases in direct proportion to the train speed. There exist two major fequency components in the pantograph motion related to the current collection, a speed-dependent component arising from the train traversing a span of the catenary, and a speed-independent component related to the pantograph resonant frequency. The train acceleration is also found to exert strong influence on the current collection system characteristics. The effect of the train motion is found to be stronger on the speed-dependent frequency component than on the speed-independent one.

REACTION TIME, SEMEN OUTPUT AND SEMEN QUALITY OF BUFFALO BULLS AFTER PRE-COLLECTION INJECTION OF PROSTAGLANDIN F2 ALPHA (PGF2 ALPHA)

  • Capitan, S.S.;Antiporda, G.S.;Momongan, V.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권4호
    • /
    • pp.343-346
    • /
    • 1990
  • A study was conducted to determine the effect of prostaglandin $F_2$ alpha ($PGF_2$ alpha) on the reaction time and seminal characteristics of buffalo bulls. Semen was collected from three Murrah bulls in three periods: pre-treatment, treatment and post-treatment. During the treatment period each bull was administered 2 ml $PGF_2$ alpha (Synchrocept, Fenprostalene) im, 1 hour prior to semen collection. In the post-treatment, semen was collected 7 days after the last injection of $PGF_2$. Semen samples were evaluated immediately after collection. Pre-collection injection of $PGF_2$ alpha has no significant effect on reaction time, semen volume, percentage motility, sperm concentration and total number of sperms per ejaculate. Fluctuations in semen color and consistency were observed. There is a significant (p<0.05) increase in the mean percentage of normal spermatozoa during the treatment and post treatment periods. Likewise, administration of PG results into a significant (p<0.05) rise on the average percentage of live sperms but this effect was not manifested in the post-treatment period. Improvement in mass activity was observed during the treatment and post-treatment periods.

A Study on Design of Real-time Big Data Collection and Analysis System based on OPC-UA for Smart Manufacturing of Machine Working

  • Kim, Jaepyo;Kim, Youngjoo;Kim, Seungcheon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권4호
    • /
    • pp.121-128
    • /
    • 2021
  • In order to design a real time big data collection and analysis system of manufacturing data in a smart factory, it is important to establish an appropriate wired/wireless communication system and protocol. This paper introduces the latest communication protocol, OPC-UA (Open Platform Communication Unified Architecture) based client/server function, applied user interface technology to configure a network for real-time data collection through IoT Integration. Then, Database is designed in MES (Manufacturing Execution System) based on the analysis table that reflects the user's requirements among the data extracted from the new cutting process automation process, bush inner diameter indentation measurement system and tool monitoring/inspection system. In summary, big data analysis system introduced in this paper performs SPC (statistical Process Control) analysis and visualization analysis with interface of OPC-UA-based wired/wireless communication. Through AI learning modeling with XGBoost (eXtream Gradient Boosting) and LR (Linear Regression) algorithm, quality and visualization analysis is carried out the storage and connection to the cloud.